Dynamic change of transmission of CaF 2 single crystals by irradiating with ArF excimer laser light

Author(s):  
Jochen Alkemper ◽  
Joerg Kandler ◽  
Lorenz Strenge ◽  
Ewald Moersen ◽  
Christian Muehlig ◽  
...  
2010 ◽  
Vol 2010.23 (0) ◽  
pp. 437-438
Author(s):  
Yuta KITAMURA ◽  
Noriyuki MIYAZAKI ◽  
Takahito KUMAZAKI ◽  
Naoto NAGAKURA ◽  
Yasuhiro HASHIMOTO ◽  
...  

1992 ◽  
Vol 279 ◽  
Author(s):  
M. Okoshi ◽  
H. Kashiura ◽  
T. Miyokawa ◽  
K. Toyoda ◽  
M. Murahara

ABSTRACTOH radicals were photochemically substituted for fluorine atoms in the teflon surface by using an ArF excimer laser light and an Al(OH)3 solution. This method is simple and can be performed in air atmosphere. In the process, the teflon film was placed on the Al(OH)3 which were dissolved in NaOH water solution; the ArF excimer laser light was irradiated the sample surface and the solution. By irradiating the laser, the surface was defluorinated by the aluminium atoms photodissociated from the Al(OH)3 solution, and the dangling bonds which were formed in the defluorinated surface combined with the OH radicals also photodissociated. The hydrophilic property of the photomodified surface was evaluated by the measurement of the contact angle with water. The defluorination and the OH radicals substitution were inspected by the XPS analysis and the ATR-FTIR measurement.


1995 ◽  
Vol 31 (11) ◽  
pp. 879-880 ◽  
Author(s):  
B. Malo ◽  
K.O. Hill ◽  
D.C. Johnson ◽  
F. Bilodeau ◽  
J. Albert ◽  
...  

2002 ◽  
Vol 735 ◽  
Author(s):  
Hitoshi Omuro ◽  
Masato Nakagawa ◽  
Hiroaki Fukuda ◽  
Masataka Murahara

ABSTRACTPET has been widely used for medical materials such as an artificial ligament. However, the affinity of tissues is no good. To compensate this, the mesh formed PET has clinically been used for artificial ligament intruding tissue into mesh. However, this method has not shown sufficient affinity with the tissue; that is, the initial adapting strength of the material and tissue is weak. · The artificial ligament must be biocompatible to contact blood and tissue. The foregoing artificial ligament, however, doesn't satisfy the biocompatibility. ·Thus, we have modified the PET surface into hydrophilic by substituting NH2 or OH functional groups. Firstly, an ArF excimer laser light was irradiated the PET with water on top. The OH functional group was substituted on the PET surface by this photochemical reaction. Secondly, the ArF excimer laser light was irradiated the PET in ammonia gas ambient. In this photochemical reaction, the NH2 functional group was substituted on the PET surface.· In this study, the untreated sample had the contact angle with water of 80 degrees and the bonding strength with protein of only 1.0kg/cm2. The contact angle of the modified sample improved to 40 degrees and the bonding strength, to 23kg/cm2. When treated in ammonia gas, the contact angle also improved to 40 degrees; however, the bonding strength was almost the same as that of the untreated sample.It was confirmed that the affinity of the PET for water and protein could be controlled by increasing or decreasing the substitution concentration of OH and NH2 functional groups on the surface.


1991 ◽  
Vol 236 ◽  
Author(s):  
T. Obara ◽  
M. Murahara

AbstractResistless etching of thermal oxide silicon filmes were demonstrated by ArF & KrF excimer lasers, and CC12F2 gases. CC12F2 was decomposed by ArF excimer laser light, and CF2 radicals were produced. These radicals, which have absorption band nearby 250nm, were vary stable. Then the circuit pattarned KrF laser light was irradiated on the SiO2 in an atomsphere of CF2 radicals. As thse result, the etching pattern of 2 μ m width was performed.


Sign in / Sign up

Export Citation Format

Share Document