scholarly journals Modeling of Bifacial Photovoltaic-Thermal (PVT) Air Heater with Jet Plate

2021 ◽  
Vol 39 (4) ◽  
pp. 1117-1122
Author(s):  
Win Eng Ewe ◽  
Ahmad Fudholi ◽  
Kamaruzzaman Sopian ◽  
Nilofar Asim

This research demonstrates how to develop a novel energy balance equation to investigate heat transmission between the components of a bifacial photovoltaic-thermal (PVT) air heater with a jet plate. The temperature output and efficiency of the system are shown. A greater mass flow rate reduces the exit air temperature and increases the thermal efficiency of the thermal component. Increased sun irradiation raises the output air temperature and thermal efficiency. In terms of electrical efficiency, a greater mass flow rate reduces the temperature of the PV panel while increasing electrical efficiency. On the other hand, higher solar irradiation raises the temperature of the PV panel, lowering its electrical efficiency. The maximum thermal efficiency of BPVTJPR is 51.09% under the circumstances of 12 PV cells with a packing factor of 0.66, a jet plate reflector with 36 holes, 900 W/m2 solar irradiances, and a mass flow rate of 0.035 kg/s. The maximum electrical efficiency of BPVTJPR is 10.73% under the circumstances of 12 PV cells with a packing factor of 0.66, a jet plate reflector with 36 holes, 700 W/m2 solar irradiances, and a mass flow rate of 0.035 kg/s.

2021 ◽  
pp. 193-193
Author(s):  
Arvind Singhy ◽  
Robin Thakur ◽  
Raj Kumar ◽  
Sushil Kumar ◽  
Sanjeev Kumar ◽  
...  

Influence of wind speed, mass flow rate of water, irradiance and ambient temperature on concentrated Photovoltaic thermal module equipped with linear FL as Primary Optic Element and Convex Lens as Secondary Optic Element have been investigated in this study. Influence of these parameters on module performance in terms of thermal efficiency and electrical efficiency are also examined during investigation. The thermal efficiency and electrical efficiency without consideration of parameters was found to be 14.3% and 51.2 % respectively. With consideration of above mentioned four parameters, the results reveal that electrical efficiency of 17.2% and thermal efficiency of 55.3% can be achieved for designed setup. Thus, there is 20% and 8% increase in electrical efficiency and thermal efficiency respectively. The electrical efficiency increases with increase in fluid flow rate, wind speed and irradiance. Electrical efficiency decreases with increase in ambient temperature. The thermal efficiency increases with increment in water mass flow rate, irradiance and ambient temperature. However, with increase in wind speed, the thermal efficiency decreases.


2016 ◽  
Vol 138 (5) ◽  
Author(s):  
A. E. Kabeel ◽  
A. Khalil ◽  
S. M. Shalaby ◽  
M. E. Zayed

In this research, the thermal performances of flat, finned, and v-corrugated plate solar air heaters were investigated experimentally. A solar air heater with single glass cover, single pass was designed and tested under prevailing weather conditions of Tanta city (30°43′ N, 31° E), Egypt. The solar air heater was designed to be easy to replace the absorber plate from one to another one. Comparisons between the temperature difference of air across the heater and thermal efficiencies of the flat, finned, and v-corrugated plate solar air heaters were presented. The effect of change in the mass flow rate of air on the outlet air temperature and the thermal efficiency of the heater were also studied when the mass flow rates were 0.062, 0.028, and 0.009 kg/s. The experimental results showed that the maximum value of outlet temperature of the v-corrugated plate solar air heater was 5 and 3.5 °C more than that of flat and finned plates when the mass flow rate was 0.062 kg/s, respectively. And, it increased to be 8 and 5.5 C when the mass flow rate was 0.009 kg/s. It is also indicated that the thermal efficiency of the v-corrugated solar air heater is 8–14.5% and 6–10.5% higher than that of the flat and finned plate heaters, respectively, when the mass flow rate was 0.062 kg/s under the considered configurations and operating conditions. The experimental results also indicated that the convective heat transfer coefficient of the v-corrugated heater reached up to 1.64 and 1.36 times than that of the flat and finned heaters, respectively, when the flow rate was 0.062 kg/s.


2016 ◽  
Vol 20 (1) ◽  
pp. 175-183 ◽  
Author(s):  
Gnanadurai Sugantharaj ◽  
Kumar Vijay ◽  
Kalidasa Kulundaivel

Solar air heating is a technology in which the solar energy from the sun is captured by an absorbing medium and used to heat the air flowing through the heater. In this study, thermal performance of a double pass solar air heater has been investigated experimentally at different conditions. The experiments were conducted with different inclinations of the collector, with and without wire mesh vertically fixed at the second pass in transverse direction and with different mass flow rates. The effect of air mass flow rate, wire mesh pitch and collector inclination on temperature rise and thermal efficiency have been studied. Results show that efficiency increases with mass flow rate. For the same mass flow rate, the thermal efficiency increases with the decrease in the wire mesh pitch. The maximum daily average efficiency of air heater was 79.8% at 0.025 kg/s mass flow rate, 10 cm wire mesh gap and 9? collector inclination facing south. The highest collector efficiency was observed in solar air heaters with 10 cm wire mesh gap.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2950
Author(s):  
Vinod Kumar ◽  
Liqiang Duan

Coal consumption and CO2 emissions are the major concerns of the 21st century. Solar aided (coal-fired) power generation (SAPG) is paid more and more attention globally, due to the lesser coal rate and initial cost than the original coal-fired power plant and CSP technology respectively. In this paper, the off-design dynamic performance simulation model of a solar aided coal-fired power plant is established. A 330 MW subcritical coal-fired power plant is taken as a case study. On a typical day, three various collector area solar fields are integrated into the coal-fired power plant. By introducing the solar heat, the variations of system performances are analyzed at design load, 75% load, and 50% load. Analyzed parameters with the change of DNI include the thermal oil mass flow rate, the mass flow rate of feed water heated by the solar energy, steam extraction mass flow rate, coal consumption, and the plant thermal efficiency. The research results show that, as DNI increases over a day, the coal saving rate will also increase, the maximum coal saving rate reaches up to 5%, and plant thermal efficiency reaches 40%. It is analyzed that the SAPG system gives the best performance at a lower load and a large aperture area.


Author(s):  
Mohamad Modrek ◽  
Ali Al-Alili

Photovoltaic thermal collectors (PVT) combines technologies of photovoltaic panels and solar thermal collectors into a hybrid system by attaching an absorber to the back surface of a PV panel. PVT collectors have gained a lot of attention recently due to the high energy output per unit area compared to a standalone system of PV panels and solar thermal collectors. In this study, performance of a liquid cooled flat PVT collector under the climatic conditions of Abu Dhabi, United Arab Emirates was experimentally investigated. The electrical performances of the PVT collector was compared to that of a standalone PV panel. Moreover, effect of sand accumulation on performance of PVT collectors was examined. Additionally, effect of mass flow rate on thermal and electrical output of PVT collector was studied. Electrical power output is slightly affected by changes in mass flow rate. However, thermal energy increased by 22% with increasing flow rate. Electrical power output of a PV panel was found to be 38% lower compared to electrical output of PVT collectors. Dust accumulation on PVT surface reduced electrical power output up to 7% compared with a reference PVT collector.


2018 ◽  
Vol 22 (1 Part B) ◽  
pp. 487-494 ◽  
Author(s):  
Aminreza Noghrehabadi ◽  
Ebrahim Hajidavaloo ◽  
Mojtaba Moravej ◽  
Ali Esmailinasab

Solar collectors are the key part of solar water heating systems. The most widely produced solar collectors are flat plate solar collectors. In the present study, two types of flat plate collectors, namely square and rhombic collectors are experi?mentally tested and compared and the thermal performance of both collectors is investigated. The results show both collectors have the same performance around noon (?61%), but the rhombic collector has better performance in the morning and afternoon. The values for rhombic and square collectors are approximately 56.2% and 53.5% in the morning and 56.1% and 54% in the afternoon, respectively. The effect of flow rate is also studied. The thermal efficiency of rhombic and square flat plate collectors increases in proportion to the flow rate. The results indicated the rhombic collector had better performance in comparison with the square collector with respect to the mass-flow rate.


Energies ◽  
2020 ◽  
Vol 13 (5) ◽  
pp. 1105 ◽  
Author(s):  
Carlo Carcasci ◽  
Lapo Cheli ◽  
Pietro Lubello ◽  
Lorenzo Winchler

This paper presents an off-design analysis of a gas turbine Organic Rankine Cycle (ORC) combined cycle. Combustion turbine performances are significantly affected by fluctuations in ambient conditions, leading to relevant variations in the exhaust gases’ mass flow rate and temperature. The effects of the variation of ambient air temperature have been considered in the simulation of the topper cycle and of the condenser in the bottomer one. Analyses have been performed for different working fluids (toluene, benzene and cyclopentane) and control systems have been introduced on critical parameters, such as oil temperature and air mass flow rate at the condenser fan. Results have highlighted similar power outputs for cycles based on benzene and toluene, while differences as high as 34% have been found for cyclopentane. The power output trend with ambient temperature has been found to be influenced by slope discontinuities in gas turbine exhaust mass flow rate and temperature and by the upper limit imposed on the air mass flow rate at the condenser as well, suggesting the importance of a correct sizing of the component in the design phase. Overall, benzene-based cycle power output has been found to vary between 4518 kW and 3346 kW in the ambient air temperature range considered.


2018 ◽  
Vol 141 (1) ◽  
Author(s):  
Clifford K. Ho ◽  
Joshua M. Christian ◽  
Julius E. Yellowhair ◽  
Kenneth Armijo ◽  
William J. Kolb ◽  
...  

This paper evaluates the on-sun performance of a 1 MW falling particle receiver. Two particle receiver designs were investigated: obstructed flow particle receiver versus free-falling particle receiver. The intent of the tests was to investigate the impact of particle mass flow rate, irradiance, and particle temperature on the particle temperature rise and thermal efficiency of the receiver for each design. Results indicate that the obstructed flow design increased the residence time of the particles in the concentrated flux, thereby increasing the particle temperature and thermal efficiency for a given mass flow rate. The obstructions, a staggered array of chevron-shaped mesh structures, also provided more stability to the falling particles, which were prone to instabilities caused by convective currents in the free-fall design. Challenges encountered during the tests included nonuniform mass flow rates, wind impacts, and oxidation/deterioration of the mesh structures. Alternative materials, designs, and methods are presented to overcome these challenges.


Micromachines ◽  
2020 ◽  
Vol 11 (3) ◽  
pp. 323 ◽  
Author(s):  
Jojomon Joseph ◽  
Danish Rehman ◽  
Michel Delanaye ◽  
Gian Luca Morini ◽  
Rabia Nacereddine ◽  
...  

Miniaturized heat exchangers are well known for their superior heat transfer capabilities in comparison to macro-scale devices. While in standard microchannel systems the improved performance is provided by miniaturized distances and very small hydraulic diameters, another approach can also be followed, namely, the generation of local turbulences. Localized turbulence enhances the heat exchanger performance in any channel or tube, but also includes an increased pressure loss. Shifting the critical Reynolds number to a lower value by introducing perturbators controls pressure losses and improves thermal efficiency to a considerable extent. The objective of this paper is to investigate in detail collector performance based on reduced-order modelling and validate the numerical model based on experimental observations of flow maldistribution and pressure losses. Two different types of perturbators, Wire-net and S-shape, were analyzed. For the former, a metallic wire mesh was inserted in the flow passages (hot and cold gas flow) to ensure stiffness and enhance microchannel efficiency. The wire-net perturbators were replaced using an S-shaped perturbator model for a comparative study in the second case mentioned above. An optimum mass flow rate could be found when the thermal efficiency reaches a maximum. Investigation of collectors with different microchannel configurations (s-shaped, wire-net and plane channels) showed that mass flow rate deviation decreases with an increase in microchannel resistance. The recirculation zones in the cylindrical collectors also changed the maldistribution pattern. From experiments, it could be observed that microchannels with S-shaped perturbators shifted the onset of turbulent transition to lower Reynolds number values. Experimental studies on pressure losses showed that the pressure losses obtained from numerical studies were in good agreement with the experiments (<4%).


Author(s):  
Pablo Fernández del Campo ◽  
Fletcher Miller ◽  
Adam Crocker

We present an investigation of the effects of the solar irradiation and mass flow conditions on the behavior of a Small Particle Solar Receiver employing our new, three-dimensional coupled fluid flow and radiative heat transfer model. This research expands on previous work conducted by our group and utilizes improved software with a set of new features that allows performing more flexible simulations and obtaining more accurate results. For the first time, it is possible not only to accurately predict the overall efficiency and the wall temperature distribution of the solar receiver, but also to determine the effect on the receiver of the window, the outlet tube, real solar irradiation from a heliostat field, non-cylindrical geometries and 3-D effects. This way, a much better understanding of the receiver’s capabilities is obtained. While the previous models were useful to observe simple trends, this new software is flexible and accurate enough to eventually act as a design and optimization tool for the actual receiver. The solution procedure relies on the coupling of the CFD package ANSYS Fluent to our in-house Monte Carlo Ray Trace (MCRT) software. On the one hand, ANSYS Fluent is utilized as the mass-, momentum- and energy-equation solver and requires the divergence of the radiative heat flux, which constitutes a source term of the energy equation. On the other hand, the MCRT software calculates the radiation heat transfer in the solar receiver and needs the temperature field to do so. By virtue of the coupled nature of the problem, both codes should provide feed-back to each other and iterate until convergence. The coupling between ANSYS Fluent and our in-house MCRT code is done via User-Defined Functions. After developing the mathematical model, setting up and validating the software, and optimizing the coupled solution procedure, the receiver has been simulated under fifteen different solar irradiation and mass flow rate cross combinations. Among other results, the behavior of the receiver at different times of the day and the optimum mass flow rate as a function of the solar thermal input are presented. On an average day, the thermal efficiency of the receiver is found to be over 89% and the outlet temperature over 1250 K at all times from 7:30 AM to 4:00 PM (Albuquerque, NM) by properly adapting the mass flow rate. The origin of the losses and how to improve the efficiency of the Small Particle Solar Receiver are discussed as well.


Sign in / Sign up

Export Citation Format

Share Document