Three-Dimensional Fluid Dynamics and Radiative Heat Transfer Modeling of a Small Particle Solar Receiver

Author(s):  
Pablo Fernández del Campo ◽  
Fletcher Miller ◽  
Adam Crocker

We present an investigation of the effects of the solar irradiation and mass flow conditions on the behavior of a Small Particle Solar Receiver employing our new, three-dimensional coupled fluid flow and radiative heat transfer model. This research expands on previous work conducted by our group and utilizes improved software with a set of new features that allows performing more flexible simulations and obtaining more accurate results. For the first time, it is possible not only to accurately predict the overall efficiency and the wall temperature distribution of the solar receiver, but also to determine the effect on the receiver of the window, the outlet tube, real solar irradiation from a heliostat field, non-cylindrical geometries and 3-D effects. This way, a much better understanding of the receiver’s capabilities is obtained. While the previous models were useful to observe simple trends, this new software is flexible and accurate enough to eventually act as a design and optimization tool for the actual receiver. The solution procedure relies on the coupling of the CFD package ANSYS Fluent to our in-house Monte Carlo Ray Trace (MCRT) software. On the one hand, ANSYS Fluent is utilized as the mass-, momentum- and energy-equation solver and requires the divergence of the radiative heat flux, which constitutes a source term of the energy equation. On the other hand, the MCRT software calculates the radiation heat transfer in the solar receiver and needs the temperature field to do so. By virtue of the coupled nature of the problem, both codes should provide feed-back to each other and iterate until convergence. The coupling between ANSYS Fluent and our in-house MCRT code is done via User-Defined Functions. After developing the mathematical model, setting up and validating the software, and optimizing the coupled solution procedure, the receiver has been simulated under fifteen different solar irradiation and mass flow rate cross combinations. Among other results, the behavior of the receiver at different times of the day and the optimum mass flow rate as a function of the solar thermal input are presented. On an average day, the thermal efficiency of the receiver is found to be over 89% and the outlet temperature over 1250 K at all times from 7:30 AM to 4:00 PM (Albuquerque, NM) by properly adapting the mass flow rate. The origin of the losses and how to improve the efficiency of the Small Particle Solar Receiver are discussed as well.

Author(s):  
Gaowen Liu ◽  
Zhao Lei ◽  
Aqiang Lin ◽  
Qing Feng ◽  
Yan Chen

The pre-swirl system is of great importance for temperature drop and cooling air supply. This study aims to investigate the influencing mechanism of heat transfer, nonuniform thermodynamic characteristics, and cooling air supply sensitivity in a pre-swirl system by the application of the flow control method of the pre-swirl nozzle. A novel test rig was proposed to actively control the supplied cooling air mass flow rate by three adjustable pre-swirl nozzles. Then, the transient problem of the pre-swirl system was numerically conducted by comparison with 60°, 120°, and 180° rotating disk cavity cases, which were verified with the experiment results. Results show that the partial nozzle closure will aggravate the fluctuation of air supply mass flow rate and temperature. When three parts of nozzles are closed evenly at 120° in the circumferential direction, the maximum value of the nonuniformity coefficient of air supply mass flow rate changes to 3.1% and that of temperature changes to 0.25%. When six parts of nozzles are closed evenly at 60° in the circumferential direction, the maximum nonuniformity coefficient of air supply mass flow rate changes to 1.4% and that of temperature changes to 0.20%. However, different partial nozzle closure modes have little effect on the average air supply parameters. Closing 14.3% of the nozzle area will reduce the air supply mass flow rate by 9.9% and the average air supply temperature by about 1 K.


2010 ◽  
Vol 132 (4) ◽  
Author(s):  
Yoon Jo Kim ◽  
Yogendra K. Joshi ◽  
Andrei G. Fedorov ◽  
Young-Joon Lee ◽  
Sung-Kyu Lim

It is now widely recognized that the three-dimensional (3D) system integration is a key enabling technology to achieve the performance needs of future microprocessor integrated circuits (ICs). To provide modular thermal management in 3D-stacked ICs, the interlayer microfluidic cooling scheme is adopted and analyzed in this study focusing on a single cooling layer performance. The effects of cooling mode (single-phase versus phase-change) and stack/layer geometry on thermal management performance are quantitatively analyzed, and implications on the through-silicon-via scaling and electrical interconnect congestion are discussed. Also, the thermal and hydraulic performance of several two-phase refrigerants is discussed in comparison with single-phase cooling. The results show that the large internal pressure and the pumping pressure drop are significant limiting factors, along with significant mass flow rate maldistribution due to the presence of hot-spots. Nevertheless, two-phase cooling using R123 and R245ca refrigerants yields superior performance to single-phase cooling for the hot-spot fluxes approaching ∼300 W/cm2. In general, a hybrid cooling scheme with a dedicated approach to the hot-spot thermal management should greatly improve the two-phase cooling system performance and reliability by enabling a cooling-load-matched thermal design and by suppressing the mass flow rate maldistribution within the cooling layer.


2003 ◽  
Vol 125 (1) ◽  
pp. 104-113 ◽  
Author(s):  
Chang-Yuan Liu ◽  
Ying-Huei Hung

Both experimental and theoretical investigations on the heat transfer and flow friction characteristics of compact cold plates have been performed. From the results, the local and average temperature rises on the cold plate surface increase with increasing chip heat flux or decreasing air mass flow rate. Besides, the effect of chip heat flux on the thermal resistance of cold plate is insignificant; while the thermal resistance of cold plate decreases with increasing air mass flow rate. Three empirical correlations of thermal resistance in terms of air mass flow rate with a power of −0.228 are presented. As for average Nusselt number, the effect of chip heat flux on the average Nusselt number is insignificant; while the average Nusselt number of the cold plate increases with increasing Reynolds number. An empirical relationship between Nu¯cp and Re can be correlated. In the flow frictional aspect, the overall pressure drop of the cold plate increases with increasing air mass flow rate; while it is insignificantly affected by chip heat flux. An empirical correlation of the overall pressure drop in terms of air mass flow rate with a power of 1.265 is presented. Finally, both heat transfer performance factor “j” and pumping power factor “f” decrease with increasing Reynolds number in a power of 0.805; while they are independent of chip heat flux. The Colburn analogy can be adequately employed in the study.


Author(s):  
Yang Chen ◽  
Jun Li ◽  
Chaoyang Tian ◽  
Gangyun Zhong ◽  
Xiaoping Fan ◽  
...  

The aerodynamic performance of three-stage turbine with different types of leakage flows was experimentally and numerically studied in this paper. The leakage flows of three-stage turbine included the shroud seal leakage flow between the rotor blade tip and case, the diaphragm seal leakage flow between the stator blade diaphragm and shaft, as well as the shaft packing leakage flow and the gap leakage flow between the rotor blade curved fir-tree root and wheel disk. The total aerodynamic performance of three-stage turbine including leakage flows was firstly experimentally measured. The detailed flow field and aerodynamic performance were also numerically investigated using three-dimensional Reynolds-Averaged Navier-Stokes (RANS) and S-A turbulence model. The numerical mass flow rate and efficiency showed well agreement with experimental data. The effects of leakage flows between the fir-tree root and the wheel disk were studied. All leakage mass flow fractions, including the mass flow rate in each hole for all sets of root gaps were given for comparison. The effect of leakage flow on the aerodynamic performance of three-stage was illustrated and discussed.


In this investigation of multi heat pipe induced in heat exchanger shows the developments in heat transfer is to improve the efficiency of heat exchangers. Water is used as a heat transfer fluid and acetone is used as a working fluid. Rotameter is set to measure the flow rate of cold water and hot water. To maintain the parameter as experimental setup. Then set the mass flow rate of hot water as 40 LPH, 60LPH, 80 LPH, 100LPH, 120 LPH and mass flow rate of cold water as 20 LPH, 30 LPH, 40 LPH, 50 LPH, and 60 LPH. Then 40 C, 45 ºC, 50 ºC, 55 C, 60 ºC are the temperatures of hot water at inlet are maintained. To find some various physical parameters of Qc , hc , Re ,, Pr , Rth. The maximum effectiveness of the investigation obtained from condition of Thi 60 C, Tci 32 C and 100 LPH mhi, 60 LPH mci the maximum effectiveness attained as 57.25. Then the mhi as 100 LPH, mci as 60 LPH and Thi at 40 C as 37.6%. It shows the effectiveness get increased about 34.3 to the maximum conditions.


2020 ◽  
Vol 82 (3) ◽  
Author(s):  
Muji Setiyo ◽  
Budi Waluyo ◽  
Nurkholis Hamidi

The ½ cycle refrigeration system on LPG fueled vehicles has a significant cooling effect. However, the cooling is very dependent on the heat exchange process in the evaporator. Therefore, this paper analyses the deviation of the actual cooling curve from the ideal scenario carried out on a laboratory scale. The analytical method used is the calculation of the effectiveness of the evaporator, which compares the actual to the potential heat transfer capacity. The LPG flow rate was varied from 1-6 g/s, while the evaporation pressure ranged between 0.05, 0.10, and 0.15 MPa, which applied to compact type evaporators with dimensions of 262 ´ 200 mm, with a thickness of 65 mm. The research results confirm that the higher the LPG mass flow rate, the lower the heat transfer effectiveness. At the higher LPG mass flow rate, heat transfer occurs less optimally,  due to incomplete evaporation of LPG in the evaporator.


Author(s):  
Xingyun Jia ◽  
Liguo Wang ◽  
Qun Zheng ◽  
Hai Zhang ◽  
Yuting Jiang

Performance of generic rim seal configurations, axial-clearance rim seal (ACS), radial-clearance rim seal (RCS), radial-axial clearance rim seal (RACS) are compared under realistic working conditions. Conjugate heat transfer analysis on rim seal is performed in this paper to understand the impact of ingestion on disc temperature. Results show that seal effectiveness and cooling effectiveness of RACS are the best when compared with ACS and RCS, the minimum mass flow rate for seal of RACS is 75% of that of RCS, and 34.6% of ACS. Authors compare the disc temperature distribution between different generic rim seal configurations where the RACS seems to be favorable in terms of low disc temperature. In addition, RACS has higher air-cooled aerodynamic efficiency, minimizing the mainstream performance penalty when compared with ACS and RCS. Corresponding to the respective minimum mass flow rate for seal, the air-cooled aerodynamic efficiency of RACS is 23.71% higher than that of ACS, and 12.79% higher than the RCS.


2021 ◽  
Author(s):  
Jun Dong ◽  
Hao Wang ◽  
Samuel Darr ◽  
Jason Hartwig ◽  
Jacob Chung

Abstract This is the second part of a two-part series that presents the results of liquid nitrogen spray quenching of a Stainless Steel disc. The results of continuous-flow spray chilldown of a bare surface disc are summarized first that serves as the baseline information for evaluating the effects of disc surface coating and pulse flow. We found that for continuous-flow spray chilldown of a bare surface disc, the chilldown efficiency is mainly a function of the average mass flow rate with the trend of decreasing efficiency with increasing mass flow rate. Additional experiments were performed to evaluate the enhancement of cryogenic spray quenching by three techniques: 1. Using intermittent pulse sprays on SS bare surface, 2. Coating the SS surface with a layer of low thermal conductivity Teflon film, and 3. Spraying liquid nitrogen intermittently on the coated SS surface. In general, the results indicate that all three methods effectively produced higher spray thermal efficiencies and reduced liquid nitrogen mass consumption. However, it was also found that the Teflon coating was more effective than the flow pulsing due to that the Teflon coating induced a large surface temperature drop at the beginning of the chilldown that allowed the quenching to move quickly from poor heat transfer film boiling to efficient heat transfer transition and nucleate boiling regimes. This quick transition shortens the film boiling period, thus facilitates the switch to much higher heat transfer transition boiling and nucleate boiling periods earlier to complete the chilldown process faster.


Sign in / Sign up

Export Citation Format

Share Document