Investigation of the Thermal Performances of Flat, Finned, and v-Corrugated Plate Solar Air Heaters

2016 ◽  
Vol 138 (5) ◽  
Author(s):  
A. E. Kabeel ◽  
A. Khalil ◽  
S. M. Shalaby ◽  
M. E. Zayed

In this research, the thermal performances of flat, finned, and v-corrugated plate solar air heaters were investigated experimentally. A solar air heater with single glass cover, single pass was designed and tested under prevailing weather conditions of Tanta city (30°43′ N, 31° E), Egypt. The solar air heater was designed to be easy to replace the absorber plate from one to another one. Comparisons between the temperature difference of air across the heater and thermal efficiencies of the flat, finned, and v-corrugated plate solar air heaters were presented. The effect of change in the mass flow rate of air on the outlet air temperature and the thermal efficiency of the heater were also studied when the mass flow rates were 0.062, 0.028, and 0.009 kg/s. The experimental results showed that the maximum value of outlet temperature of the v-corrugated plate solar air heater was 5 and 3.5 °C more than that of flat and finned plates when the mass flow rate was 0.062 kg/s, respectively. And, it increased to be 8 and 5.5 C when the mass flow rate was 0.009 kg/s. It is also indicated that the thermal efficiency of the v-corrugated solar air heater is 8–14.5% and 6–10.5% higher than that of the flat and finned plate heaters, respectively, when the mass flow rate was 0.062 kg/s under the considered configurations and operating conditions. The experimental results also indicated that the convective heat transfer coefficient of the v-corrugated heater reached up to 1.64 and 1.36 times than that of the flat and finned heaters, respectively, when the flow rate was 0.062 kg/s.

2021 ◽  
Vol 39 (5) ◽  
pp. 1649-1658
Author(s):  
Subhash Chand ◽  
Prabha Chand

The aim of the present study to improve the performance of solar air heater because of low thermo-physical properties of air. In the current work, an attempt has been made to improve the performance of the heater by employing louvered fins to the absorber plate, as it not only enhances heat transfer coefficient but also improve heat transfer area. The effect of exergy performance on the geometrical parameters of louvered fin i.e., louvered angle, louvered pitch and louvered length has been studied and analyzed. The results are compared to plane solar air heater (PSAH) to evaluate the effectiveness of louvered finned solar air heater (LFSAH). The exergy efficiency of LFSAH is comparatively higher for all the operating conditions except for higher mass flow rate where it may even go below that of PSAH; possibly due to the higher pressure drop and more loss of exergy at high mass flow rate. In addition, the results conclude that for louvered parameters viz., louvered angle 20°, fin pitch to louvered pitch ratio 0.75 and louvered length to louvered pitch ratio 1.25, high exergy performance of SAH is obtained as compared to other louvered parameter values.


2021 ◽  
Vol 3 (2) ◽  
pp. 49-55
Author(s):  
Atul Kumar ◽  
Prabhakar Bhandari ◽  
K.S. Rawat

This paper presents a theoretical investigation of solar air heater using phase change material (PCM). PCM used in present configuration is homogenous mixture of paraffin wax with Aluminium powder. The purpose of using Aluminium powder with paraffin wax is to increase the thermal conductivity. PCM mixtures are encapsulated in cylinders and are used as solar absorbers. Using MATLAB program, the effect of different parameters is studied. It has been observed that with increase in mass flow rate, air outlet temperature decreases and freezing time of cylinder decreases. However, at constant mass flow rate, with increase in cylinder radius, air temperature decreases and while freezing time increase sharply. The different parameters have  to be chosen such that performance of solar air heater can be optimized.


2018 ◽  
Vol 22 (6 Part A) ◽  
pp. 2389-2399 ◽  
Author(s):  
Duraisamy Jagadeesh ◽  
Ramasamy Venkatachalam ◽  
Gurusamy Nallakumarasamy

Evaluation of experimental thermal performance of a single pass solar air dryer is compared with a transient CFD studies is performed. Vertical hollow plates are placed below the absorber plate and compared against the flat solar absorber plate for its performance improvement. Effect of mass-flow rate, the outlet temperature of air is computationally analyzed in comparison with the experimental work, transient boundary conditions for CFD like ambient temperature, solar insolation are taken from the experimental work, and computational results are in good agreement of with experimental results with maximum error percentage of 10%. Thermal efficiency was increased with increase in mass-flow area for without fin configuration, for a specific mass-flow rate thermal efficiency had a good improvement with fin configuration than the without fin configuration.


2016 ◽  
Vol 20 (1) ◽  
pp. 175-183 ◽  
Author(s):  
Gnanadurai Sugantharaj ◽  
Kumar Vijay ◽  
Kalidasa Kulundaivel

Solar air heating is a technology in which the solar energy from the sun is captured by an absorbing medium and used to heat the air flowing through the heater. In this study, thermal performance of a double pass solar air heater has been investigated experimentally at different conditions. The experiments were conducted with different inclinations of the collector, with and without wire mesh vertically fixed at the second pass in transverse direction and with different mass flow rates. The effect of air mass flow rate, wire mesh pitch and collector inclination on temperature rise and thermal efficiency have been studied. Results show that efficiency increases with mass flow rate. For the same mass flow rate, the thermal efficiency increases with the decrease in the wire mesh pitch. The maximum daily average efficiency of air heater was 79.8% at 0.025 kg/s mass flow rate, 10 cm wire mesh gap and 9? collector inclination facing south. The highest collector efficiency was observed in solar air heaters with 10 cm wire mesh gap.


2021 ◽  
Vol 39 (4) ◽  
pp. 1117-1122
Author(s):  
Win Eng Ewe ◽  
Ahmad Fudholi ◽  
Kamaruzzaman Sopian ◽  
Nilofar Asim

This research demonstrates how to develop a novel energy balance equation to investigate heat transmission between the components of a bifacial photovoltaic-thermal (PVT) air heater with a jet plate. The temperature output and efficiency of the system are shown. A greater mass flow rate reduces the exit air temperature and increases the thermal efficiency of the thermal component. Increased sun irradiation raises the output air temperature and thermal efficiency. In terms of electrical efficiency, a greater mass flow rate reduces the temperature of the PV panel while increasing electrical efficiency. On the other hand, higher solar irradiation raises the temperature of the PV panel, lowering its electrical efficiency. The maximum thermal efficiency of BPVTJPR is 51.09% under the circumstances of 12 PV cells with a packing factor of 0.66, a jet plate reflector with 36 holes, 900 W/m2 solar irradiances, and a mass flow rate of 0.035 kg/s. The maximum electrical efficiency of BPVTJPR is 10.73% under the circumstances of 12 PV cells with a packing factor of 0.66, a jet plate reflector with 36 holes, 700 W/m2 solar irradiances, and a mass flow rate of 0.035 kg/s.


Solar air heater is a major component of solar dryer. A model of multi pass solar air heater (MPSAH) with reversed absorber and reflector was developed. Exhaustive Study over the performance of MPSAH with and without reversed absorber and cost analysis was done. The performance curves show the effect of solar intensity on MPSAH with and without reversed absorber at constant mass flow. It was observed that the thermal efficiency of MPSAH is depending on solar intensity and losses when mass flow rate remain constant. At constant mass flow rate 26.90 gm/sec, the collector efficiency increased by 9% at average solar intensity 457w/m². Theoretical and experimental analysis showed close agreement. In addition the cost-effectiveness model has been used to examine the performance MPSAH with and without reverse absorbers. The air heaters annual cost (AC) estimation and annual power acquirement (AG) was analyze. The result is evidence for that multi-pass solar air heater with reverse absorbers and reflector is more cost-effective than multi-pass solar collectors without reverse absorber.


2020 ◽  
Vol 12 (9) ◽  
pp. 3619
Author(s):  
Afaq Jasim Mahmood

In this study, an experimental outdoor investigation of the thermal efficiency and outlet air temperature was conducted on an unglazed, double-pass, solar air heater with a perforated absorber plate and packing wire mesh layers as a supplemental absorbent area. This was done to observe their effects on the thermal performance of the solar air heater. The double-pass collector was constructed with a bed height of 0.05 m, and a collection area of 1.5 m2. The height of the upper channel was fixed at 0.015 m to improve the thermal efficiency, and the outlet temperature at air flow rates between 0.003 and 0.018 kg/s. The collector was mounted with a slope of 42° facing south, to maximize the intensity of solar irradiance during winter. The effects of the air flow rate, ambient temperature, inlet temperature, outlet temperature, and solar intensity were experimentally investigated. The results showed that thermal efficiency could be improved by increasing the air flow rate, where the highest thermal efficiency achieved was 86% at 0.018 kg/s. However, the temperature difference was increased to a maximum value of 38.6 °C, when the air flow rate was decreased to 0.003 kg/s. Furthermore, the results demonstrated a significant improvement in the thermal efficiency and outlet temperature; and when compared with previous research, the experimental results and the predictions for the outlet temperature using the theoretical model agreed.


2018 ◽  
Vol 7 (1) ◽  
pp. 59 ◽  
Author(s):  
Mohammad Hossein Ahmadi ◽  
Mohammad Ali Afshar ◽  
Ali Naseri ◽  
Mokhtar Bidi ◽  
H. Hadiyanto

The aim of this study is modeling a solar-air heater humidification-dehumidification unit with applying particle swarm optimization to find out  the maximum gained output ratio with respect to the mass flow rate of water and air entering humidifier, mass flow rate of cooling water entering dehumidifier, width and length of solar air heater and terminal temperature difference (TTD) of dehumidifier representing temperature difference of inlet cooling water and saturated air to dehumidifier as its decision variable. A sensitivity analysis, furthermore, is performed to distinguish the effect of operating parameters including mass flow rate and streams’ temperature. The results showed that the optimum productivity decreases by decreasing the ratio of mass flow rate of water entering humidifier to air ones.Article History: Received: July 12th 2017; Revised: December 15th 2017; Accepted: 2nd February 2018; Available onlineHow to Cite This Article: Afshar, M.A., Naseri, A., Bidi, M., Ahmadi, M.H. and Hadiyanto, H. (2018) Modeling and PSO Optimization of Humidifier-Dehumidifier Desalination. International Journal of Renewable Energy Development, 7(1),59-64.https://doi.org/10.14710/ijred.7.1.59-64


2017 ◽  
Vol 2017 ◽  
pp. 1-14 ◽  
Author(s):  
Seyyed Mahdi Taheri Mousavi ◽  
Fuat Egelioglu

The thermal performances of three slit-glazed solar air heaters (SGSAHs) were investigated experimentally. Three SGSAHs with different bed heights (7 cm, 5 cm, and 3 cm) were fabricated with multiple glass panes used for glazing. The length, width, and thickness of each pane were 154 cm, 6 cm, and 0.4 cm, respectively. Ambient air was continuously withdrawn through the gaps between the glass panes by fans. The experiments were conducted for four different gap distances between the glass panes (0.5 mm, 1 mm, 2 mm, and 3 mm) and the air mass flow rate was varied between 0.014 kg/s and 0.057 kg/s. The effects of air mass flux on the outlet temperature and thermal efficiency were studied. For the SGSAH with bed height of 7 cm and glass pane gap distance of 0.5 mm, the highest efficiency was obtained as 82% at a mass flow rate of 0.057 kg/s and the air temperature difference between the inlet and the outlet (∆T) was maximum (27°C) when the mass flow rate was least. The results demonstrate that for lower mass flow rates and larger gaps, the performance of SGSAH with a bed height of 3 cm was better compared to that of others. However, for higher mass flow rates, the SGSAH with 7 cm bed height performed better.