About Homogeneity of CVD Diamond Nuclear Particles Detectors

1995 ◽  
Vol 416 ◽  
Author(s):  
C. Manfredotti ◽  
F. Fizzotti ◽  
P. Polesello ◽  
E. Vittone ◽  
M. Jaksic ◽  
...  

ABSTRACTCVD diamond films show both at optical microscope and at SEM a quasi-columnar structure, not homogeneously distributed in the bulk which is agreed to be responsible for the relatively large charge collection lengths measured in the material. In this work, we present the first data on charge collection efficiency distributions as measured directly in the bulk by a 3 Meν proton microbeam. The results indicate that the material is really non-homogeneous, that only few columns are really connecting both electrodes and that, finally, a real connection exists between the morphological structure and the maps of collection efficiency distribution.

1999 ◽  
Vol 588 ◽  
Author(s):  
E. Borchi ◽  
M. Bruzzi ◽  
L. Lombardi ◽  
D. Menichelli ◽  
S. Miglio ◽  
...  

AbstractCombined TSC and PICTS measurements have been used to determine the activation energies (Et) and capture cross-sections (σ) of the trap levels inside the bandgap of CVD diamond in the energy range 0.4−0.7 eV. High temperature TSC analysis has been performed to determine the trap parameters in the energy range from 0.9 to 1.3 eV. A fieldmap in the Et−σ plane has been obtained from the combination of the TSC and PICTS data depicting the regions corresponding to two isolated trap levels and to a continuous distribution of states. The concentrations of defects have been calculated from the TSC signals and the measurement of the charge collection efficiency of the diamond samples.


2002 ◽  
Vol 16 (06n07) ◽  
pp. 1018-1023 ◽  
Author(s):  
J. AHN ◽  
B. GAN ◽  
Q. ZHANG ◽  
S. F. YOON ◽  
V. LIGATCHEV ◽  
...  

The CVD diamond UV photodetector shows more than four orders of photoresponsivity discrimination between UV and visible light. Post-treatment on as-fabricated photodetector is essential for a good response to UV light and blindness to visible light. The CVD diamond X-ray detector shows linear dependence of photocurrent on X-ray intensity and high response speed. The mapping of charge collection efficiency on the whole sensing area of a CVD diamond alpha particle detector has been obtained using ion-beam-induced charge microscopy technique. Three peaks have been observed in the charge collection spectrum.


2002 ◽  
Vol 49 (1) ◽  
pp. 277-280 ◽  
Author(s):  
A. Brambilla ◽  
D. Tromson ◽  
P. Bergonzo ◽  
C. Mer ◽  
F. Foulon

2013 ◽  
Vol 8 (03) ◽  
pp. C03023-C03023 ◽  
Author(s):  
M Jakubek ◽  
J Jakubek ◽  
J Zemlicka ◽  
M Platkevic ◽  
V Havranek ◽  
...  

Sign in / Sign up