Proton Irradiation Damage in Zn and Cd Doped InP

1993 ◽  
Vol 325 ◽  
Author(s):  
George C. Rybicki ◽  
Wendell S. Williams

AbstractDeep Level Transient Spectroscopy (DLTS) was used to study the defects introduced in Zn and Cd doped Schottky barrier diodes by 2 MeV proton irradiation. The defects H3, H4 and H5 were observed in lightly Zn doped InP, while only the defects H3 and H5 were observed in more heavily Zn doped and Cd doped InP. The defect activation energies and capture cross sections did not vary between the Zn and Cd doped InP.The concentration of the radiation induced defects was also measured. The introduction rate of the defect H4 in the lightly Zn doped InP and the introduction rate of the defect H3 in the heavily Zn and Cd doped InP were about equal, but the introduction rate of the defect H5 varied strongly among the three types of material. The introduction rate of H5 was highest in the heavily Zn doped InP but the lowest in the heavily Cd doped InP, even though they were doped comparably. As a result, the total defect introduction rate was lowest in the highly Cd doped InP.The results can be interpreted in terms of the models for the formation and annealing of defects, and by the different diffusion rates of Zn and Cd in InP.

2011 ◽  
Vol 679-680 ◽  
pp. 547-550
Author(s):  
Rupert C. Stevens ◽  
Konstantin Vassilevski ◽  
John E. Lees ◽  
Nicolas G. Wright ◽  
Alton B. Horsfall

Detectors capable of withstanding high radiation environments for prolonged periods of exposure are essential for the monitoring of nuclear power stations and nuclear waste as well as for space exploration. Schottky diode X-ray detectors were exposed to high dose proton irradiation (1013 cm-2, 50 MeV) and changes in the detection resolution (spectroscopic full width half-maximum) have been observed. Using Deep Level Transient Spectroscopy (DLTS) and the degradation of the electrical characteristics of the diode, we have shown that radiation induced traps located in the upper half of the bandgap have reduced the concentration of carriers.


2003 ◽  
Vol 763 ◽  
Author(s):  
Richard S. Crandall

AbstractThis paper presents data showing a Meyer-Neldel rule (MNR) in InGaAsN alloys. It is shown that without this knowledge, significant errors will be made using Deep-Level Transient-Spectroscopy (DLTS) emission data to determine capture cross sections. By correctly accounting for the MNR in analyzing the DLTS data the correct value of the cross section is obtained.


2002 ◽  
Vol 389-393 ◽  
pp. 489-492 ◽  
Author(s):  
Atsuo Kawasuso ◽  
Michael Weidner ◽  
F. Redmann ◽  
Thomas Frank ◽  
Reinhard Krause-Rehberg ◽  
...  

2015 ◽  
Vol 66 (6) ◽  
pp. 323-328 ◽  
Author(s):  
Ladislav Harmatha ◽  
Miroslav Mikolášek ◽  
L’ubica Stuchlíková ◽  
Arpád Kósa ◽  
Milan Žiška ◽  
...  

Abstract The contribution is focused on the diagnostics of structures with a heterojunction between amorphous and crystalline silicon prepared by HIT (Heterojunction with an Intrinsic Thin layer) technology. The samples were irradiated by Xe ions with energy 167 MeV and doses from 5 × 108 cm−2 to 5 × 1010 cm−2. Radiation defects induced in the bulk of Si and at the hydrogenated amorphous silicon and crystalline silicon (a-Si:H/c-Si) interface were identified by Deep Level Transient Spectroscopy (DLTS). Radiation induced A-centre traps, boron vacancy traps and different types of divacancies with a high value of activation energy were observed. With an increased fluence of heavy ions the nature and density of the radiation induced defects was changed.


Author(s):  
Ivana Capan ◽  
Tomislav Brodar ◽  
Takahiro Makino ◽  
Vladimir Radulovic ◽  
Luka Snoj

We report on metastable defects introduced in n-type 4H-SiC material by epithermal and fast neutron irradiation. The epithermal and fast neutron irradiation defects in 4H-SiC are much less explored compared to electron or proton irradiation induced defects. In addition to silicon vacancy (Vsi) and carbon antisite-carbon vacancy (CAV) complex, the neutron irradiation has introduced four deep level defects, all arising from the metastable defect, the M-center. The metastable deep level defects were investigated by deep level transient spectroscopy (DLTS), high-resolution Laplace DLTS (L-DLTS) and isothermal DLTS. The existence of the fourth deep level M4, recently observed in ion implanted 4H-SiC, has been additionally confirmed in neutron irradiated samples. The isothermal DLTS technique has been proven as a useful tool for studying the metastable defects.


Sign in / Sign up

Export Citation Format

Share Document