Noninvasive monitoring of cerebral blood oxygenation with optoacoustic technique: An in vivo study in sheep

Author(s):  
Y. Y. Petrov ◽  
D. S. Prough ◽  
M. Klasing ◽  
D. J. Deyo ◽  
R. O. Esenaliev
2009 ◽  
Vol 17 (9) ◽  
pp. 7285 ◽  
Author(s):  
I. Y. Petrova ◽  
Y. Y. Petrov ◽  
R. O. Esenaliev ◽  
D. J. Deyo ◽  
I. Cicenaite ◽  
...  

2005 ◽  
Vol 102 (1) ◽  
pp. 69-75 ◽  
Author(s):  
Yuriy Y. Petrov ◽  
Donald S. Prough ◽  
Donald J. Deyo ◽  
Manfred Klasing ◽  
Massoud Motamedi ◽  
...  

Background Current, invasive cerebral oxygenation monitors require either retrograde jugular venous bulb cannulation or intraparenchymal probe insertion. There is no accurate, noninvasive, continuous monitor of cerebral blood oxygenation. Methods The authors designed, built, and tested novel optoacoustic instrumentation that continuously measures blood oxygenation in the superior sagittal sinus (SSS) in vivo in 12 anesthetized sheep. In this technique, laser pulses generate acoustic signals, the amplitudes and slopes of which are proportional to oxyhemoglobin saturation in the SSS. Optoacoustic signals from the SSS measured through the scalp and cranium were compared with directly measured oxyhemoglobin saturation in blood withdrawn from the cannulated SSS. Results In the first experiments (feasibility), FIO2 changes produced rapid corresponding changes in optoacoustic signals and arterial oxygen saturation. In the second experiments (validation), the authors correlated oxyhemoglobin saturation in the SSS with optoacoustic signals and developed quantifying algorithms. In eight of nine validation experiments, the authors quantified optoacoustic signals by subtracting the temporal profile at low FIO2 (0.08-0.1) from profiles at higher FIO2 and integrating those signals in the range from 3 to 5 micros. In each validation experiment, optoacoustic signals showed tight temporal association and good linear correlation with measured oxyhemoglobin saturation (r2 0.75 to 0.99 for eight individual experiments). Conclusions The optoacoustic system detects signals induced in the SSS and optoacoustic signals from the SSS linearly correlate with oxyhemoglobin saturation. The data suggest that the optoacoustic technique merits clinical evaluation.


2005 ◽  
Vol 25 (1_suppl) ◽  
pp. S57-S57
Author(s):  
Ken-ichiro Kasura ◽  
Megumi Watanabe ◽  
Kumiko Takahashi ◽  
Genki Mizukoshi ◽  
Seiji Ohkubo ◽  
...  

Diabetes ◽  
2019 ◽  
Vol 68 (Supplement 1) ◽  
pp. 321-LB
Author(s):  
ANETA ALAMA ◽  
DOROTA PAWE?KA ◽  
ANETA MYSZCZYSZYN ◽  
MALGORZATA MALODOBRA-MAZUR

Diabetes ◽  
1986 ◽  
Vol 35 (9) ◽  
pp. 973-978 ◽  
Author(s):  
L. Capron ◽  
J. Jarnet ◽  
S. Kazandjian ◽  
E. Housset

Sign in / Sign up

Export Citation Format

Share Document