scholarly journals High resolution 3D imaging of integrated circuits by x-ray ptychography

Author(s):  
Michal Odstrcil ◽  
Mirko Holler ◽  
Jörg Raabe ◽  
Manuel Guizar-Sicairos
Author(s):  
Halit Dogan ◽  
Md Mahbub Alam ◽  
Navid Asadizanjani ◽  
Sina Shahbazmohamadi ◽  
Domenic Forte ◽  
...  

Abstract X-ray tomography is a promising technique that can provide micron level, internal structure, and three dimensional (3D) information of an integrated circuit (IC) component without the need for serial sectioning or decapsulation. This is especially useful for counterfeit IC detection as demonstrated by recent work. Although the components remain physically intact during tomography, the effect of radiation on the electrical functionality is not yet fully investigated. In this paper we analyze the impact of X-ray tomography on the reliability of ICs with different fabrication technologies. We perform a 3D imaging using an advanced X-ray machine on Intel flash memories, Macronix flash memories, Xilinx Spartan 3 and Spartan 6 FPGAs. Electrical functionalities are then tested in a systematic procedure after each round of tomography to estimate the impact of X-ray on Flash erase time, read margin, and program operation, and the frequencies of ring oscillators in the FPGAs. A major finding is that erase times for flash memories of older technology are significantly degraded when exposed to tomography, eventually resulting in failure. However, the flash and Xilinx FPGAs of newer technologies seem less sensitive to tomography, as only minor degradations are observed. Further, we did not identify permanent failures for any chips in the time needed to perform tomography for counterfeit detection (approximately 2 hours).


Author(s):  
E.L. Principe ◽  
Navid Asadizanjani ◽  
Domenic Forte ◽  
Mark Tehranipoor ◽  
Robert Chivas ◽  
...  

Abstract This paper discusses the development of an extensible programmatic workflow that leverages evolving technologies in 2D/3D imaging, distributed instrument control, image processing, and automated mechanical/chemical deprocessing technology. Initial studies involve automated backside mechanical ultra-thinning of 65nm node IC processor chips in combination with SEM imaging and X-ray tomography. Areas as large as 800μm x 800μm were deprocessed using gas-assisted plasma FIB delayering. Ongoing work involves enhancing the workflow with “intelligent automation” by bridging FIB-SEM instrument control and near real-time data analysis to establish a computationally guided microscopy suite.


2010 ◽  
Author(s):  
Leilei Yin ◽  
Ying-Chieh Chen ◽  
Jeff Gelb ◽  
Darren M. Stevenson ◽  
Paul A. Braun

2019 ◽  
Vol 508 ◽  
pp. 3-14 ◽  
Author(s):  
Antonin Richard ◽  
Christophe Morlot ◽  
Laura Créon ◽  
Nicolas Beaudoin ◽  
Vladimir S. Balistky ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document