Cohort Study of the Pathogenesis and Molecular Epidemiology of Catheter-Related Bloodstream Infection in Neonates With Peripherally Inserted Central Venous Catheters

2008 ◽  
Vol 29 (3) ◽  
pp. 243-249 ◽  
Author(s):  
Jeffery S. Garland ◽  
Colleen P. Alex ◽  
Jackie M. Sevallius ◽  
Dawn M. Murphy ◽  
Mary J. Good ◽  
...  

Objective.To better define the pathogenesis of catheter-related bloodstream infection (BSI) in neonates with peripherally inserted central venous catheters (PICCs) to guide the development of more effective strategies for prevention.Design.Prospective nested cohort study.Setting.Level III neonatal intensive care unit in a community hospital.Methods.During a randomized trial to assess the safety and efficacy of a prophylactic vancomycin-heparin catheter-lock solution for the prevention of catheter-related BSI in neonates with PICCs, we performed cultures of peripheral and catheter-drawn blood samples, and quantitative cultures of catheter hub samples if BSI was suspected clinically. We performed semiquantitative cultures of the catheter tip and the catheter hub and the skin at the insertion site when the catheter was removed. Molecular subtyping by pulsed-field electrophoresis was used to determine the probable pathogenesis of all BSIs due to coagulase-negative staphylococci (CoNS); for BSIs caused by other microorganisms, epidemiologic concordance was based on speciation and antibiograms. Catheter-related BSI was considered extraluminally acquired if concordance was demonstrable solely between isolates recovered from the catheter tip and the blood, independent of concordance with isolates recovered from the insertion site. Catheter-related BSI was considered intraluminally acquired if concordance was demonstrated only between isolates recovered from the catheter hub and the blood. The source of the infection was considered indeterminate if both concordance patterns were present.Results.Nosocomial BSI was identified in 23 of the 82 neonates in the cohort. Fifteen of these infections, 14 of which were caused by CoNS, were considered definite or probable catheter-related BSIs. Catheter-related BSI was intraluminally acquired in 10 (67%) of 15 patients, extraluminally acquired in 3 (20%), and indeterminate in 2 (13%).Conclusions.Most catheter-related BSIs in neonates with PICCs are caused by CoNS and derive from intraluminal contamination. Strategies for prevention of catheter-related BSI directed at this predominant mechanism of infection are most likely to be effective.

2020 ◽  
Vol 41 (7) ◽  
pp. 854-856
Author(s):  
Janita Ferreira ◽  
Paulo Augusto Moreira Camargos ◽  
Viviane Rosado ◽  
Leni Márcia Anchieta ◽  
Roberta Maia de Castro Romanelli

AbstractCatheter-drawn blood sampling is an efficient method of diagnosing catheter-related bloodstream infection (CRBSI) in neonates; it has greater sensitivity and accuracy than methods using catheter-tip cultures. No association was detected between catheter-drawn blood sampling and the occurrence of adverse events with central venous catheters.


2004 ◽  
Vol 23 (3) ◽  
pp. 82-83 ◽  
Author(s):  
Carol Trotter

PERIPHERALLY INSERTED CENTRAL venous catheters (PICCs) are used as the standard of care for longterm intravenous access in neonates treated in neonatal intensive care units. Little evidence supports many of the practices associated with PICC lines, however. Some practices needing more evidence include catheter tip placement in very low birth weight neonates, the catheter insertion site, the catheter material, insertion site dressings, and mechanisms to prevent catheter-related sepsis. Of particular concern is the practice of trimming the excess length off the distal end of the catheter prior to insertion.


2017 ◽  
Vol 5 ◽  
Author(s):  
Gerdina H. Dubbink-Verheij ◽  
Vincent Bekker ◽  
Iris C. M. Pelsma ◽  
Erik W. van Zwet ◽  
Vivianne E. H. J. Smits-Wintjens ◽  
...  

2009 ◽  
Vol 30 (7) ◽  
pp. 698-701 ◽  
Author(s):  
Stefania Bezzio ◽  
C. Scolfaro ◽  
R. Broglia ◽  
R. Calabrese ◽  
F. Mignone ◽  
...  

This prospective observational study was designed to assess the incidence of, risk factors for, and outcome of catheter-related bloodstream infection in children undergoing cardiac surgery. A staff specifically trained to handle the central venous catheters with proper aseptic techniques and an appropriate patient to medical staff ratio remain the most effective measures to prevent this infection.


2003 ◽  
Vol 31 (1) ◽  
pp. 52-59 ◽  
Author(s):  
Marco Ranucci ◽  
Giuseppe Isgrò ◽  
Pier Paolo Giomarelli ◽  
Marco Pavesi ◽  
Aldo Luzzani ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document