Performance of Individual Hearing Aids Utilizing Microphone and Induction Coil Input

1971 ◽  
Vol 14 (2) ◽  
pp. 365-371 ◽  
Author(s):  
Richard J. Sung ◽  
William R. Hodgson

Physical measurements of gain, maximum power output, frequency response, and harmonic distortion were made on each of two body-type hearing aids on both the microphone and induction coil settings. In addition, we investigated speech intelligibility through each aid, for both acoustic and magnetic input, using 32 normal-hearing subjects. Our findings indicated that different hearing aids provide different sensitivity for loop induction. For a given hearing aid, physical characteristics varied between the microphone and the telephone coil settings. The intelligibility of speech produced by a given mode of signal input, either microphone or telephone coil, was dependent on physical characteristics of the hearing aid. The usable high-frequency response and the configuration of the response curve in the region of 1500 to 3000 Hz appeared to be associated with the intelligibility of monosyllabic words.

1990 ◽  
Vol 33 (4) ◽  
pp. 676-689 ◽  
Author(s):  
David A. Fabry ◽  
Dianne J. Van Tasell

The Articulation Index (AI) was used to evaluate an “adaptive frequency response” (AFR) hearing aid with amplification characteristics that automatically change to become more high-pass with increasing levels of background noise. Speech intelligibility ratings of connected discourse by normal-hearing subjects were predicted well by an empirically derived AI transfer function. That transfer function was used to predict aided speech intelligibility ratings by 12 hearing-impaired subjects wearing a master hearing aid with the Argosy Manhattan Circuit enabled (AFR-on) or disabled (AFR-off). For all subjects, the AI predicted no improvements in speech intelligibility for the AFR-on versus AFR-off condition, and no significant improvements in rated intelligibility were observed. The ability of the AI to predict aided speech intelligibility varied across subjects. However, ratings from every hearing-impaired subject were related monotonically to AI. Therefore, AI calculations may be used to predict relative—but not absolute—levels of speech intelligibility produced under different amplification conditions.


1971 ◽  
Vol 14 (2) ◽  
pp. 323-331 ◽  
Author(s):  
Daniel L. Bode ◽  
Roger N. Kasten

An experiment was conducted with 34 normal-hearing listeners to determine the effects of distortion (generated by a single hearing aid) on consonant identification in noise. Five experimental conditions were employed in which measured harmonic distortion ranged from approximately 1% (high fidelity) to 35%. Each listening condition involved playback of recorded test material at a constant sensation level. Results showed that average consonant identification scores, relative to the high-fidelity condition, decreased 15–29% as a function of increased distortion. Initial consonants were discriminated best across all distortion conditions, and progressive increases in distortion tended to most affect final consonants. The data also suggested possible talker/hearing aid interactions. Reduced high-frequency response and altered speech-to-noise ratio, together with harmonic distortion, were postulated as mutually inclusive causes of the observed decrements in consonant differentiation.


1985 ◽  
Vol 50 (2) ◽  
pp. 132-141 ◽  
Author(s):  
David B. Hawkins ◽  
Donald J. Schum

A variety of electroacoustic characteristics was measured on four hearing aids and then repeated with the hearing aids connected to two different FM systems via three coupling methods: direct input, neck loop, and silhouette inductor. The measurements included frequency response, harmonic distortion, noise levels, input-output functions, and FM receiver volume control wheel taper curves. Omnidirectional and directional FM microphones were compared in a classroom environment, and minor changes in hearing aid-silhouette coupling were investigated. Large differences were found in some frequency response comparisons, with no single coupling method providing consistently better agreement with the hearing aid alone response. With the exception of the silhouette inductor, distortion and noise levels were similar for the hearing aids and FM-hearing aid combinations. Differences in the input-output functions between the hearing aids and the FM systems were observed. Some FM-hearing aid combinations produced very nonlinear FM receiver volume control wheel taper curves. The output level of a broadband noise in a classroom was reduced when a directional FM microphone was compared to the omnidirectional version. The results indicate that it cannot be assumed that the electroacoustic characteristics of a personal hearing aid are preserved when it is connected to an FM system.


1966 ◽  
Vol 9 (2) ◽  
pp. 253-258 ◽  
Author(s):  
James Jerger ◽  
Carolyn Malmquist ◽  
Charles Speaks

A sentence intelligibility test and three monosyllabic word intelligibility tests, recorded through three hearing aids, were presented to 36 subjects with diverse types of hearing loss. Although hearing aids were rank ordered meaningfully on the sentence intelligibility test-in inverse proportion to the harmonic distortion-performance differences were not systematically reflected in the monosyllabic word test results.


1977 ◽  
Vol 20 (4) ◽  
pp. 718-730
Author(s):  
Thomas H. Townsend ◽  
Daniel M. Schwartz

Measurements of hearing aid performance were made using four different electroacoustic systems. Nine hearing aids were evaluated three times in each of the four systems: a standard Bruel and Kjaer apparatus, a Fonix 5000, and both a Phonic Ear HC 1000 and HC 2000. Tests included frequency response and, when possible, total harmonic distortion, second harmonic distortion, and third harmonic distortion. Results were equivalent for frequency response and second harmonic distortion, whereas significant differences occurred for total harmonic distortion and third harmonic distortion at both the low and high frequencies. The degree to which the sum of second harmonic distortion and third harmonic distortion fails to equal the total harmonic distortion was also examined. In the low frequency region, second harmonic distortion plus third harmonic distortion yielded values considerably less than the total harmonic distortion, although good agreement was found in the midfrequencies.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


Author(s):  
Isiaka Ajewale Alimi

Digital hearing aids addresses the issues of noise and speech intelligibility that is associated with the analogue types. One of the main functions of the digital signal processor (DSP) of digital hearing aid systems is noise reduction which can be achieved by speech enhancement algorithms which in turn improve system performance and flexibility. However, studies have shown that the quality of experience (QoE) with some of the current hearing aids is not up to expectation in a noisy environment due to interfering sound, background noise and reverberation. It is also suggested that noise reduction features of the DSP can be further improved accordingly. Recently, we proposed an adaptive spectral subtraction algorithm to enhance the performance of communication systems and address the issue of associated musical noise generated by the conventional spectral subtraction algorithm. The effectiveness of the algorithm has been confirmed by different objective and subjective evaluations. In this study, an adaptive spectral subtraction algorithm is implemented using the noise-estimation algorithm for highly non-stationary noisy environments instead of the voice activity detection (VAD) employed in our previous work due to its effectiveness. Also, signal to residual spectrum ratio (SR) is implemented in order to control the amplification distortion for speech intelligibility improvement. The results show that the proposed scheme gives comparatively better performance and can be easily employed in digital hearing aid system for improving speech quality and intelligibility.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


2016 ◽  
Vol 27 (03) ◽  
pp. 219-236 ◽  
Author(s):  
Susan Scollie ◽  
Danielle Glista ◽  
Julie Seto ◽  
Andrea Dunn ◽  
Brittany Schuett ◽  
...  

Background: Although guidelines for fitting hearing aids for children are well developed and have strong basis in evidence, specific protocols for fitting and verifying technologies can supplement such guidelines. One such technology is frequency-lowering signal processing. Children require access to a broad bandwidth of speech to detect and use all phonemes including female /s/. When access through conventional amplification is not possible, the use of frequency-lowering signal processing may be considered as a means to overcome limitations. Fitting and verification protocols are needed to better define candidacy determination and options for assessing and fine tuning frequency-lowering signal processing for individuals. Purpose: This work aims to (1) describe a set of calibrated phonemes that can be used to characterize the variation in different brands of frequency-lowering processors in hearing aids and the verification with these signals and (2) determine whether verification with these signal are predictive of perceptual changes associated with changes in the strength of frequency-lowering signal processing. Finally, we aimed to develop a fitting protocol for use in pediatric clinical practice. Study Sample: Study 1 used a sample of six hearing aids spanning four types of frequency lowering algorithms for an electroacoustic evaluation. Study 2 included 21 adults who had hearing loss (mean age 66 yr). Data Collection and Analysis: Simulated fricatives were designed to mimic the level and frequency shape of female fricatives extracted from two sources of speech. These signals were used to verify the frequency-lowering effects of four distinct types of frequency-lowering signal processors available in commercial hearing aids, and verification measures were compared to extracted fricatives made in a reference system. In a second study, the simulated fricatives were used within a probe microphone measurement system to verify a wide range of frequency compression settings in a commercial hearing aid, and 27 adult listeners were tested at each setting. The relation between the hearing aid verification measures and the listener’s ability to detect and discriminate between fricatives was examined. Results: Verification measures made with the simulated fricatives agreed to within 4 dB, on average, and tended to mimic the frequency response shape of fricatives presented in a running speech context. Some processors showed a greater aided response level for fricatives in running speech than fricatives presented in isolation. Results with listeners indicated that verified settings that provided a positive sensation level of /s/ and that maximized the frequency difference between /s/ and /∫/ tended to have the best performance. Conclusions: Frequency-lowering signal processors have measureable effects on the high-frequency fricative content of speech, particularly female /s/. It is possible to measure these effects either with a simple strategy that presents an isolated simulated fricative and measures the aided frequency response or with a more complex system that extracts fricatives from running speech. For some processors, a more accurate result may be achieved with a running speech system. In listeners, the aided frequency location and sensation level of fricatives may be helpful in predicting whether a specific hearing aid fitting, with or without frequency-lowering, will support access to the fricatives of speech.


1980 ◽  
Vol 45 (2) ◽  
pp. 247-258 ◽  
Author(s):  
Dianne J. Van Tasell ◽  
Deborah P. Landin

Personally sized inductance loops (mini-loops) now are available for use with an FM classroom amplification system and the student's personal ear-level hearing aid. Frequency response characteristics of five commercially-available hearing aids were assessed 1) using hearing aid test equipment available in most audiology clinics, with the hearing aid on microphone setting and 2) in a public school classroom, with the hearing aid on telecoil setting and operating with an FM mini-loop system. Clinic and classroom characteristics of the conventional FM receiver-insert earphone auditory trainers also were assessed. Results showed that the personal hearing aids' classroom performance could not be predicted from their clinic performance. Results also showed that gain provided by the environmental microphone circuit of the FM receiver-insert earphone units was uniformly higher than that provided by the teacher-microphone signal route.