A Comparison of Four Hearing Aid Measurement Systems

1977 ◽  
Vol 20 (4) ◽  
pp. 718-730
Author(s):  
Thomas H. Townsend ◽  
Daniel M. Schwartz

Measurements of hearing aid performance were made using four different electroacoustic systems. Nine hearing aids were evaluated three times in each of the four systems: a standard Bruel and Kjaer apparatus, a Fonix 5000, and both a Phonic Ear HC 1000 and HC 2000. Tests included frequency response and, when possible, total harmonic distortion, second harmonic distortion, and third harmonic distortion. Results were equivalent for frequency response and second harmonic distortion, whereas significant differences occurred for total harmonic distortion and third harmonic distortion at both the low and high frequencies. The degree to which the sum of second harmonic distortion and third harmonic distortion fails to equal the total harmonic distortion was also examined. In the low frequency region, second harmonic distortion plus third harmonic distortion yielded values considerably less than the total harmonic distortion, although good agreement was found in the midfrequencies.

1980 ◽  
Vol 45 (3) ◽  
pp. 325-335 ◽  
Author(s):  
Jerry L. Punch ◽  
Edwin L. Beck

Connected discourse was processed by a master hearing aid via two channels that were independently adjusted to seven discrete settings of low-cutoff frequency. Signals were tape-recorded and played back in a paired-comparison format to 12 listeners with gradually sloping sensorineural hearing loss, who selected the speech channel preferred for its sound quality. Four experimental trials were administered, each of which consisted of 21 randomized paired conditions. Results across the four trials revealed high intersubject and intrasubject response agreement. Listeners indicated strong and systematic preferences for speech reproduced by circuitry having progressively extended low-frequency emphasis. Findings confirm earlier experimental observations that hearing-impaired listeners are capable of making repeatable paired-comparison preference judgments of the quality of hearing-aid processed speech. Additionally, results demonstrate definitively that low-cutoff frequency is sufficiently robust to be regarded as the probable source of a potent perceptual basis for such judgments. The clinical implication is that hearing-impaired listeners can be expected to exhibit strong preferences for the quality of speech reproduced by hearing aids having relatively extended low-frequency response.


1971 ◽  
Vol 14 (2) ◽  
pp. 365-371 ◽  
Author(s):  
Richard J. Sung ◽  
William R. Hodgson

Physical measurements of gain, maximum power output, frequency response, and harmonic distortion were made on each of two body-type hearing aids on both the microphone and induction coil settings. In addition, we investigated speech intelligibility through each aid, for both acoustic and magnetic input, using 32 normal-hearing subjects. Our findings indicated that different hearing aids provide different sensitivity for loop induction. For a given hearing aid, physical characteristics varied between the microphone and the telephone coil settings. The intelligibility of speech produced by a given mode of signal input, either microphone or telephone coil, was dependent on physical characteristics of the hearing aid. The usable high-frequency response and the configuration of the response curve in the region of 1500 to 3000 Hz appeared to be associated with the intelligibility of monosyllabic words.


1985 ◽  
Vol 50 (2) ◽  
pp. 132-141 ◽  
Author(s):  
David B. Hawkins ◽  
Donald J. Schum

A variety of electroacoustic characteristics was measured on four hearing aids and then repeated with the hearing aids connected to two different FM systems via three coupling methods: direct input, neck loop, and silhouette inductor. The measurements included frequency response, harmonic distortion, noise levels, input-output functions, and FM receiver volume control wheel taper curves. Omnidirectional and directional FM microphones were compared in a classroom environment, and minor changes in hearing aid-silhouette coupling were investigated. Large differences were found in some frequency response comparisons, with no single coupling method providing consistently better agreement with the hearing aid alone response. With the exception of the silhouette inductor, distortion and noise levels were similar for the hearing aids and FM-hearing aid combinations. Differences in the input-output functions between the hearing aids and the FM systems were observed. Some FM-hearing aid combinations produced very nonlinear FM receiver volume control wheel taper curves. The output level of a broadband noise in a classroom was reduced when a directional FM microphone was compared to the omnidirectional version. The results indicate that it cannot be assumed that the electroacoustic characteristics of a personal hearing aid are preserved when it is connected to an FM system.


1992 ◽  
Vol 35 (2) ◽  
pp. 418-429 ◽  
Author(s):  
Francis K. Kuk ◽  
Nonalee M. C. Pape

The reliability of a modified simplex procedure to select the preferred frequency response on a programmable hearing aid was studied. The effect of stimulus materials on the selected frequency response, along with the consistency in which the selected frequency response was chosen in repeated test runs, was examined. Two groups of hearing-impaired elderly adults (from 59 to 88 years of age, with a mean age of 70 years) who had worn hearing aids for at least 1 year, participated in the study. Subjects were seen for six sessions lasting 2 to 3 hours each. During each session, subjects listened through a programmable hearing aid and selected a preferred frequency response for optimal hearing using a modified simplex procedure. Discourse passages and consonant nonsense syllables, presented in quiet and in noise, were used as the test conditions. Subjective judgment of discourse clarity and syllable recognition were used as criteria. Three estimates of preferred frequency response were obtained within a session when subjective judgment was used as a criterion and two estimates were obtained within a session when syllable recognition was used as a criterion. Subjects returned for a retest approximately 1 week after completion of all test conditions. The results of the study revealed that, depending on test conditions, approximately 30% of subjects selected the same frequency response and 80% of subjects showed test-retest deviation of less than one step size (one cell) in the selected frequency response. The consistency was highest for discourse material presented in noise and lowest for discourse material presented in quiet. Subjects preferred more high-frequency response when consonant syllables were used for recognition than when discourse was used for subjective judgment. On the other hand, more subjects preferred more low-frequency response for discourse judgment than for consonant-syllable recognition. These results suggest that the choice of stimulus materials affect the outcome and consistency in which these outcomes are generated with the simplex procedure.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.


2016 ◽  
Vol 27 (03) ◽  
pp. 219-236 ◽  
Author(s):  
Susan Scollie ◽  
Danielle Glista ◽  
Julie Seto ◽  
Andrea Dunn ◽  
Brittany Schuett ◽  
...  

Background: Although guidelines for fitting hearing aids for children are well developed and have strong basis in evidence, specific protocols for fitting and verifying technologies can supplement such guidelines. One such technology is frequency-lowering signal processing. Children require access to a broad bandwidth of speech to detect and use all phonemes including female /s/. When access through conventional amplification is not possible, the use of frequency-lowering signal processing may be considered as a means to overcome limitations. Fitting and verification protocols are needed to better define candidacy determination and options for assessing and fine tuning frequency-lowering signal processing for individuals. Purpose: This work aims to (1) describe a set of calibrated phonemes that can be used to characterize the variation in different brands of frequency-lowering processors in hearing aids and the verification with these signals and (2) determine whether verification with these signal are predictive of perceptual changes associated with changes in the strength of frequency-lowering signal processing. Finally, we aimed to develop a fitting protocol for use in pediatric clinical practice. Study Sample: Study 1 used a sample of six hearing aids spanning four types of frequency lowering algorithms for an electroacoustic evaluation. Study 2 included 21 adults who had hearing loss (mean age 66 yr). Data Collection and Analysis: Simulated fricatives were designed to mimic the level and frequency shape of female fricatives extracted from two sources of speech. These signals were used to verify the frequency-lowering effects of four distinct types of frequency-lowering signal processors available in commercial hearing aids, and verification measures were compared to extracted fricatives made in a reference system. In a second study, the simulated fricatives were used within a probe microphone measurement system to verify a wide range of frequency compression settings in a commercial hearing aid, and 27 adult listeners were tested at each setting. The relation between the hearing aid verification measures and the listener’s ability to detect and discriminate between fricatives was examined. Results: Verification measures made with the simulated fricatives agreed to within 4 dB, on average, and tended to mimic the frequency response shape of fricatives presented in a running speech context. Some processors showed a greater aided response level for fricatives in running speech than fricatives presented in isolation. Results with listeners indicated that verified settings that provided a positive sensation level of /s/ and that maximized the frequency difference between /s/ and /∫/ tended to have the best performance. Conclusions: Frequency-lowering signal processors have measureable effects on the high-frequency fricative content of speech, particularly female /s/. It is possible to measure these effects either with a simple strategy that presents an isolated simulated fricative and measures the aided frequency response or with a more complex system that extracts fricatives from running speech. For some processors, a more accurate result may be achieved with a running speech system. In listeners, the aided frequency location and sensation level of fricatives may be helpful in predicting whether a specific hearing aid fitting, with or without frequency-lowering, will support access to the fricatives of speech.


1980 ◽  
Vol 45 (2) ◽  
pp. 247-258 ◽  
Author(s):  
Dianne J. Van Tasell ◽  
Deborah P. Landin

Personally sized inductance loops (mini-loops) now are available for use with an FM classroom amplification system and the student's personal ear-level hearing aid. Frequency response characteristics of five commercially-available hearing aids were assessed 1) using hearing aid test equipment available in most audiology clinics, with the hearing aid on microphone setting and 2) in a public school classroom, with the hearing aid on telecoil setting and operating with an FM mini-loop system. Clinic and classroom characteristics of the conventional FM receiver-insert earphone auditory trainers also were assessed. Results showed that the personal hearing aids' classroom performance could not be predicted from their clinic performance. Results also showed that gain provided by the environmental microphone circuit of the FM receiver-insert earphone units was uniformly higher than that provided by the teacher-microphone signal route.


1990 ◽  
Vol 33 (4) ◽  
pp. 676-689 ◽  
Author(s):  
David A. Fabry ◽  
Dianne J. Van Tasell

The Articulation Index (AI) was used to evaluate an “adaptive frequency response” (AFR) hearing aid with amplification characteristics that automatically change to become more high-pass with increasing levels of background noise. Speech intelligibility ratings of connected discourse by normal-hearing subjects were predicted well by an empirically derived AI transfer function. That transfer function was used to predict aided speech intelligibility ratings by 12 hearing-impaired subjects wearing a master hearing aid with the Argosy Manhattan Circuit enabled (AFR-on) or disabled (AFR-off). For all subjects, the AI predicted no improvements in speech intelligibility for the AFR-on versus AFR-off condition, and no significant improvements in rated intelligibility were observed. The ability of the AI to predict aided speech intelligibility varied across subjects. However, ratings from every hearing-impaired subject were related monotonically to AI. Therefore, AI calculations may be used to predict relative—but not absolute—levels of speech intelligibility produced under different amplification conditions.


1994 ◽  
Vol 3 (2) ◽  
pp. 71-77 ◽  
Author(s):  
James J. Dempsey ◽  
Mark Ross

A large number of personal amplifiers have recently become available commercially. These devices have not been classified as hearing aids by the FDA and are therefore not subject to the FDA rules and regulations governing the sales of hearing aid devices. In this investigation, several of these personal amplifiers were evaluated to determine potential benefits and problems for each device. The devices were evaluated electroacoustically and, also, subjectively by a group of adults with sensorineural hearing loss. The results of the electroacoustic evaluation revealed very sharply peaked frequency responses. The subjective evaluations revealed tremendous variability, with some preferences for power and low-frequency amplification. Clinical implications of these results and suggestions for further research are provided.


1986 ◽  
Vol 29 (1) ◽  
pp. 120-128 ◽  
Author(s):  
Kathryn A. Beauchaine ◽  
Michael P. Gorga ◽  
Jan K. Reiland ◽  
Lori L. Larson

This paper describes preliminary data on the use of click-evoked ABRs in the hearing aid selection process. Four normal-hearing and 4 hearing-impaired subjects were tested with a hearing aid set at three different frequency response settings. Estimates of gain were calculated using shifts in Wave V thresholds, shifts in Wave V latency-level functions, acoustic-reflex measurements, coupler gain measurements, and measurements of functional gain. Results suggest that the click-evoked ABR does not distinguish between differing amounts of low-frequency gain, although reasonable estimates of high-frequency gain appear possible. Also discussed are technical factors that must be considered when using the ABR in the hearing aid evaluation process.