scholarly journals Production and electrical characterization of the reflectin A2 isoform from Doryteuthis (Loligo) pealeii

RSC Advances ◽  
2016 ◽  
Vol 6 (62) ◽  
pp. 57103-57107 ◽  
Author(s):  
David D. Ordinario ◽  
Long Phan ◽  
Ward G. Walkup IV ◽  
Yegor Van Dyke ◽  
Erica M. Leung ◽  
...  

​We report an improved methodology for the production of cephalopod proteins known as reflectins. Our findings may afford new opportunities for the study of these proteins’ multifaceted materials properties.

Author(s):  
L.E. Murr ◽  
A.B. Draper

The industrial characterization of the machinability of metals and alloys has always been a very arbitrarily defined property, subject to the selection of various reference or test materials; and the adoption of rather naive and misleading interpretations and standards. However, it seems reasonable to assume that with the present state of knowledge of materials properties, and the current theories of solid state physics, more basic guidelines for machinability characterization might be established on the basis of the residual machined microstructures. This approach was originally pursued by Draper; and our presentation here will simply reflect an exposition and extension of this research.The technique consists initially in the production of machined chips of a desired test material on a horizontal milling machine with the workpiece (specimen) mounted on a rotary table vice. A single cut of a specified depth is taken from the workpiece (0.25 in. wide) each at a new tool location.


1981 ◽  
Vol 4 ◽  
Author(s):  
T. J. Stultz ◽  
J. F. Gibbons

ABSTRACTStructural and electrical characterization of laser recrystallized LPCVD silicon films on amorphous substrates using a shaped cw laser beam have been performed. In comparing the results to data obtained using a circular beam, it was found that a significant increase in grain size can be achieved and that the surface morphology of the shaped beam recrystallized material was much smoother. It was also found that whereas circular beam recrystallized material has a random grain structure, shaped beam material is highly oriented with a <100> texture. Finally the electrical characteristics of the recrystallized film were very good when measured in directions parallel to the grain boundaries.


2011 ◽  
Vol E94-C (2) ◽  
pp. 157-163 ◽  
Author(s):  
Masakazu MUROYAMA ◽  
Ayako TAJIRI ◽  
Kyoko ICHIDA ◽  
Seiji YOKOKURA ◽  
Kuniaki TANAKA ◽  
...  

Author(s):  
E. Hendarto ◽  
S.L. Toh ◽  
J. Sudijono ◽  
P.K. Tan ◽  
H. Tan ◽  
...  

Abstract The scanning electron microscope (SEM) based nanoprobing technique has established itself as an indispensable failure analysis (FA) technique as technology nodes continue to shrink according to Moore's Law. Although it has its share of disadvantages, SEM-based nanoprobing is often preferred because of its advantages over other FA techniques such as focused ion beam in fault isolation. This paper presents the effectiveness of the nanoprobing technique in isolating nanoscale defects in three different cases in sub-100 nm devices: soft-fail defect caused by asymmetrical nickel silicide (NiSi) formation, hard-fail defect caused by abnormal NiSi formation leading to contact-poly short, and isolation of resistive contact in a large electrical test structure. Results suggest that the SEM based nanoprobing technique is particularly useful in identifying causes of soft-fails and plays a very important role in investigating the cause of hard-fails and improving device yield.


Author(s):  
Randal Mulder ◽  
Sam Subramanian ◽  
Tony Chrastecky

Abstract The use of atomic force probe (AFP) analysis in the analysis of semiconductor devices is expanding from its initial purpose of solely characterizing CMOS transistors at the contact level with a parametric analyzer. Other uses found for the AFP include the full electrical characterization of failing SRAM bit cells, current contrast imaging of SOI transistors, measuring surface roughness, the probing of metallization layers to measure leakages, and use with other tools, such as light emission, to quickly localize and identify defects in logic circuits. This paper presents several case studies in regards to these activities and their results. These case studies demonstrate the versatility of the AFP. The needs and demands of the failure analysis environment have quickly expanded its use. These expanded capabilities make the AFP more valuable for the failure analysis community.


Author(s):  
Yuk L. Tsang ◽  
Alex VanVianen ◽  
Xiang D. Wang ◽  
N. David Theodore

Abstract In this paper, we report a device model that has successfully described the characteristics of an anomalous CMOS NFET and led to the identification of a non-visual defect. The model was based on detailed electrical characterization of a transistor exhibiting a threshold voltage (Vt) of about 120mv lower than normal and also exhibiting source to drain leakage. Using a simple graphical simulation, we predicted that the anomalous device was a transistor in parallel with a resistor. It was proposed that the resistor was due to a counter doping defect. This was confirmed using Scanning Capacitance Microscopy (SCM). The dopant defect was shown by TEM imaging to be caused by a crystalline silicon dislocation.


Author(s):  
Yuk L. Tsang ◽  
Xiang D. Wang ◽  
Reyhan Ricklefs ◽  
Jason Goertz

Abstract In this paper, we report a transistor model that has successfully led to the identification of a non visual defect. This model was based on detailed electrical characterization of a MOS NFET exhibiting a threshold voltage (Vt) of just about 40mv lower than normal. This small Vt delta was based on standard graphical extrapolation method in the usual linear Id-Vg plots. We observed, using a semilog plot, two slopes in the Id-Vg curves with Vt delta magnified significantly in the subthreshold region. The two slopes were attributed to two transistors in parallel with different Vts. We further found that one of the parallel transistors had short channel effect due to a punch-through mechanism. It was proposed and ultimately confirmed the cause was due to a dopant defect using scanning capacitance microscopy (SCM) technique.


Sign in / Sign up

Export Citation Format

Share Document