heat clearance
Recently Published Documents


TOTAL DOCUMENTS

19
(FIVE YEARS 0)

H-INDEX

8
(FIVE YEARS 0)

1991 ◽  
Vol 113 (4) ◽  
pp. 438-445 ◽  
Author(s):  
Sarit Abramovich-Sivan ◽  
Vili Benary ◽  
Thalia Kaspi ◽  
Solange Akselrod

Tissue Blood Flow is measured by applying a combined procedure of two independent approaches based on heat clearance: the Pulse Decay Method and the Continuous Method. The Pulse Method allows absolute assessment of tissue BF with no need for calibration, and can be applied only if the tissue BF is steady during the period of measurement. On the other hand, the Continuous Method enables the observation of rapid changes in tissue BF, and can be applied under non steady-state conditions. Using the combined method, a continuous quantitative measurement of transient changes in tissue BF can be obtained. For this purpose, we have developed two experimental systems consisting of independent electronic units: a Pulse Unit and a Continuous Unit. A micro-computer with dedicated software controls the operation of the electronic units and calculates tissue BF on-line. In vitro measurements are performed and demonstrate the reliability of the methods. In vivo measurements in rat brain tissue are also performed and include physiological and pharmacological changes of local tissue BF. The results of the two heat clearance methods correlate well with tissue BF values measured by a third independent method, the Hydrogen Clearance Method.


1985 ◽  
Vol 59 (6) ◽  
pp. 1902-1910 ◽  
Author(s):  
V. Hessemer ◽  
K. Bruck

In 10 women, external cold and heat exposures were performed both in the middle of luteal phase (L) and in the early follicular phase (F) of the menstrual cycle. Serum progesterone concentrations in L and F averaged 46.0 and 0.9 nmol X l-1, respectively. The experiments took place between 3:00 and 4:30 A.M., when the L-F core temperature difference is maximal. At neutral ambient temperature, esophageal (Tes), tympanic (Tty), rectal (Tre), and mean skin (Tsk) temperatures averaged 0.59 degrees C higher in L than in F. The thresholds for shivering, chest sweating, and cutaneous vasodilation (heat clearance technique) at the thumb and forearm were increased in L by an average of 0.47 degrees C, related to mean body temperature [Tb(es) = 0.87Tes + 0.13 Tsk] and to Tes, Tty, Tre, or Tsk. The above-threshold chest sweat rate and cutaneous heat clearances at the thumb and forearm were also enhanced in L, when related to Tb(es) or time. The metabolic rate, arm blood flow, and heart rate at thermoneutral conditions were increased in L by 5.0%, 1.1 ml X 100 ml-1 X min-1, and 4.6 beats X min-1, respectively. The concomitant increase in threshold temperatures for all autonomic thermoregulatory responses in L supports the concept of a resetting of the set point underlying the basal body temperature elevation in L. The effects of the increased threshold temperatures are counteracted by enhanced heat loss responses.


1975 ◽  
Vol 70 (5) ◽  
pp. 547-567 ◽  
Author(s):  
W. Müller-Schauenburg ◽  
H. Apfel ◽  
H. Benzing ◽  
E. Betz

Sign in / Sign up

Export Citation Format

Share Document