confocal technique
Recently Published Documents


TOTAL DOCUMENTS

20
(FIVE YEARS 1)

H-INDEX

4
(FIVE YEARS 0)

2021 ◽  
Vol 29 (8) ◽  
pp. 1795-1803
Author(s):  
Qian BAI ◽  
◽  
Hao MA ◽  
Jing-fei YIN ◽  

2019 ◽  
Vol 48 (2) ◽  
pp. 214-219
Author(s):  
Atakan Abusoglu ◽  
Tevhit Karacali ◽  
Hasan Efeoglu

2013 ◽  
Vol 446-447 ◽  
pp. 909-914
Author(s):  
Chun Hui Niu ◽  
Yong Lv

Chromatic confocal technique application in displacement measurement is studied theoretically and experimentally. a set of refractive lenses are designed and a measurement system is established. Correlation fitting method is proposed to fit spectrum curve and find peak wavelength. Results with use of correlation fitting method are compared with Gaussian and smoothing spline fitting methods. It indicate that correlation fitting method have higher extracting accuracy of peak wavelength and smaller RMSE of linear fitting due to narrower and smoother correlation curve.


2013 ◽  
Author(s):  
Hualing Wu ◽  
Jiamiao Yang ◽  
Liurong Qiu ◽  
Weiqian Zhao

2013 ◽  
Vol 397-400 ◽  
pp. 1738-1743
Author(s):  
Fei Li ◽  
Lin Li ◽  
Bao Yu Hong ◽  
Wen Li Liu

A collimator is one of the most popular optical instruments used in optical workshop and parallelism of the beams is the key technical indicator of collimator. A great deal of efforts has been expended to ensure reticle locate at the focal plane. In this paper, a new laser differential confocal collimator alignment method is proposed for precision alignment of collimators. Based on this principle an experimental setup is built up and used to align two collimators whose focal lengths are 600mm and 1000mm and f-numbers are both 10.The wave-front parallelism error of the laser differential confocal system and the tested collimator is measured by the verified experiment based on scanning penta prism method. At last some influence factors alignment precision is analyzed. Theoretical analysis and experimental results show that the alighment precision based on laser differential confocal method can reach to 0.004mm.and can be a high-efficiency approach to align collimators, especially in industry production.


Optik ◽  
2013 ◽  
Vol 124 (17) ◽  
pp. 2825-2828 ◽  
Author(s):  
Yun Wang ◽  
Lirong Qiu ◽  
Jiamiao Yang ◽  
Weiqian Zhao

2013 ◽  
Vol 292 ◽  
pp. 62-67 ◽  
Author(s):  
Weiqian Zhao ◽  
Junjie Guo ◽  
Lirong Qiu ◽  
Yun Wang ◽  
Jie Meng ◽  
...  

10.14311/1524 ◽  
2012 ◽  
Vol 52 (2) ◽  
Author(s):  
T. Ficker

This paper presents an attempt to find an optimal procedure for determining the height parameters of fracture surfaces. This is a useful task that may significantly increase the reliability of topographic analyses of solids. The paper focuses on seeking an optimum number of measuring sites to ensure sufficient reliability of the resulting height parameters determined by the confocal technique. The statistical tests show that the number may be close to 25 measuring sites.


Sign in / Sign up

Export Citation Format

Share Document