finger probe
Recently Published Documents


TOTAL DOCUMENTS

19
(FIVE YEARS 3)

H-INDEX

4
(FIVE YEARS 0)

2021 ◽  
Vol 30 (11) ◽  
pp. 666-670
Author(s):  
Joanna Shakespeare ◽  
Edward Parkes ◽  
Catherine Gilsenan ◽  
Asad Ali

Pulse oximetry is widely used to assess oxygen saturation (SpO2) in order to guide patient care and monitor the response to treatment. However, inappropriate oximeter probe placement has been shown to affect the measured oximetry values in healthy and normoxic outpatients. This study evaluated how treatment decisions might be impacted by SpO2 values obtained using a finger probe placed on the pinna of the ear in a cohort of 46 patients receiving non-invasive ventilation compared with values obtained from a probe on the finger and the results of arterial blood gas (ABG) (SaO2) analysis. Bland-Altman analysis was performed to evaluate agreement between the methods. Finger probe saturation was not statistically different from SaO2, with a mean difference of -0.66% (P>0.05). Saturation from the ear was significantly different (-4.29%; P<0.001). Subgroup analysis in hypoxic patients (SaO2<90%) showed a significant difference between ABG SaO2, and finger and ear SpO2. The study provides evidence that placement of a finger probe on the ear is unsafe clinical practice, potentially leading to patient mismanagement.


2020 ◽  
Vol 15 (3) ◽  
pp. 371-377
Author(s):  
Byung-Moon Choi ◽  
Bong Jin Kang ◽  
Ho-Yong Yun ◽  
Bokyoung Jeon ◽  
Ji-Yeon Bang ◽  
...  

Background: The performance of the pulse oximeter was evaluated based on the ISO 80601-2-61:2011 (E) guidelines. This study aimed to determine whether the various finger probes of the MP570T pulse oximeter (MEK-ICS Co., Ltd., Korea) would provide clinically reliable peripheral oxygen saturation (SpO2) readings over a range of 70100% arterial oxygen saturation (SaO2) during non-motion conditions.Methods: Each volunteer (n = 12) was connected to a breathing circuit for the administration of a hypoxic gas mixture. For frequent blood sampling, an arterial cannula was placed in a radial artery. The following seven pulse oximeter probes were simultaneously attached to each volunteer’s fingers: (1) WA-100 reusable finger probe (MEDNIS Co., Ltd., Korea), (2) MDNA disposable finger probe (MEDNIS Co., Ltd.), (3) IS-1011 disposable finger probe (Insung Medical Co., Ltd., Korea), (4) CJ340NA disposable finger probe (CHUN JI IN Medical Co., Ltd., Korea), (5) NellcorTM OxiMax DS-100A reusable finger probe (Medtronic, USA), (6) NellcorTM OxiMax MAX-N disposable finger probe (Medtronic), and (7) OXI-PRO DA disposable finger probe (Bio-Protech Inc., Korea). Results: A total of 275 SpO2-SaO2 pairs were included in the analysis. The accuracy of the root mean square (Arms) of each probe was 2.83%, 3.98%, 3.75%, 6.84%, 3.43%, 5.17%, and 3.84%, respectively.Conclusions: The MP570T pulse oximeter with WA-100 reusable, MDNA disposable, IS-1011 disposable, NellcorTM OxiMax DS-100A reusable, and OXI-PRO DA disposable finger probes meets an acceptable standard of SpO2 accuracy under non-motion conditions.


2016 ◽  
Vol 15 ◽  
pp. S86
Author(s):  
C. Brown ◽  
N. Rodgers ◽  
R. MacDonald ◽  
S. Cameron ◽  
J. Choyce ◽  
...  
Keyword(s):  

2013 ◽  
Vol 86 (1) ◽  
pp. 713-720 ◽  
Author(s):  
Andreas Lesch ◽  
Po-Chung Chen ◽  
Folkert Roelfs ◽  
Carsten Dosche ◽  
Dmitry Momotenko ◽  
...  