thyristor converters
Recently Published Documents


TOTAL DOCUMENTS

72
(FIVE YEARS 2)

H-INDEX

10
(FIVE YEARS 0)

2021 ◽  
Vol 25 (3) ◽  
pp. 356-368
Author(s):  
V. I. Panteleev ◽  
I. S. Kuzmin ◽  
A. A. Zavalov ◽  
A. V. Tikhonov ◽  
E. V. Umetskaia

This paper investigates the effect of the load factor of frequency converters and thyristor converters on electrical power quality. Recommendations for reducing the influence of higher harmonics and switching overvoltages on the characteristics of electrical power are provided. Higher harmonics were measured by a PKK57 complex device for controlling electrical parameters and a digital oscilloscope of the Tektronix TDS 2024V type. Impulse switching overvoltages were recorded by an active resistance divider of the DNEK-10 type and the above-mentioned oscilloscope. The obtained data were processed by the Loginom 6.4 software and the methods of mathematical statistics. The lower threshold level of the load factor of frequency converters and thyristor converters was set equal to 0.8, at which the sinusoidal distortion of voltage curves correspond to the RF standard of electrical power quality. The suppression degree of higher harmonics from the 5th to 17th frequency by power transformers with a capacity of 250–6,300 kV. A ranged from 95 to 45%. The use of the ‘transformer–converter–electric receiver’ system as applied to the power supply systems of mining and processing enterprises was substantiated. It was shown that electric motors with a capacity of up to 2,500 kW inclusively require protection against switching overvoltages. Conventional RC-absorbers based on RC-circuits connected to the terminals of electric motors are shown to be highly efficient for protecting electric motors against switching overvoltages. Thus, the quality of electrical power in power supply systems of mining and processing enterprises in Russia can be ensured by frequency converters and thyristor converters with a load factor of 0.8 or greater. Provided that the transformer capacity does not exceed 1,000 kV. A, a more efficient and less expensive ‘transformer–converter–electrical receiver’ system is recommended. Effective protection of electric motors of up to 2,500 kW inclusive can be provided using the proposed conventional RC absorber, which maintains the overvoltage rate at a level not exceeding 1.7.


2021 ◽  
Vol 289 ◽  
pp. 07015
Author(s):  
E G Usmonov ◽  
D S Akhmetbaev ◽  
M Mamutov ◽  
Sh Abdurakhmonov ◽  
M. Turgunov

This article discusses the issues of excitation of second-order subharmonic oscillations, in circuits representing a two-core electro-ferromagnetic circuit with a capacitive load, in order to use it to control the states of thyristors, frequency converters. The stability of the solutions of the equations of the two-core chain is investigated. Recommendations are given for obtaining stable subharmonic oscillations of the order 1/2 f when using these circuits as a control element of thyristor frequency dividers by two.


2020 ◽  
Vol 459 ◽  
pp. 228075 ◽  
Author(s):  
Vesa Ruuskanen ◽  
Joonas Koponen ◽  
Antti Kosonen ◽  
Markku Niemelä ◽  
Jero Ahola ◽  
...  

2015 ◽  
Vol 9 (2) ◽  
pp. 93-98
Author(s):  
Marek Gała ◽  
Kazimierz Jagieła ◽  
Andrzej Jąderko ◽  
Janusz Rak

Abstract A drive system of a section of a metallurgical rolling table consisting of six dc motors, 2220 amperes of total current, fed from a single ABB reversible thyristor converter has been described in this paper. Autonomous excitation circuits of the motors are fed from independent thyristor converters working in the so called MULTIFEX system linked with a supervisory high power converter. There are presented schemes of the DSL communication realized by FEX excitation cards of the motors using the SDSC card of the DCS-800-S02 converter and logic control system based on a PLC controller. The parameterization of the DCS-800 converter and the DCF 803 excitation systems was conducted using the DriveWindow software tool. Significant waveforms of voltages, currents and the estimated motor velocity are described and presented for the idle run as well as during transporting sheets discharged from a pusher furnace.


Sign in / Sign up

Export Citation Format

Share Document