scholarly journals Environmental Technology Assessment of Natural Gas Compared to Biogas

Natural Gas ◽  
10.5772/9837 ◽  
2010 ◽  
Author(s):  
Ola Eriksson
2012 ◽  
Author(s):  
Timothy J. Skone ◽  
James Littlefield ◽  
Robert Eckard ◽  
Greg Cooney ◽  
Joe Marriott

1999 ◽  
Author(s):  
Kendricks A. Behring II ◽  
Eric Kelner ◽  
Ali Minachi ◽  
Cecil R. Sparks ◽  
Thomas B. Morrow ◽  
...  

Author(s):  
Edgar B. Bowles ◽  
Thomas B. Morrow ◽  
Cecil R. Sparks ◽  
John G. Gregor

Automatic and remotely controlled main line valves are used in natural gas transmission pipelines to provide early shutoff of gas flow in the event of a pipeline rupture. Operating experience, however, shows that these valves and their associated rupture detection and valve operator systems are not always reliable in sensing a line break and in achieving valve closure. There are documented instances of pipeline ruptures going undetected, and of main line valves not closing completely after even a full line break. False valve closures have also occurred, causing pipelines to be shut down unnecessarily. Under sponsorship of the Gas Research Institute (GRI), a technology assessment program was conducted by Southwest Research Institute (SwRI) to define the present state of the art of automatic and remotely controlled main line valves, to evaluate their effectiveness in achieving isolation of a ruptured line, and to identify technology improvements that are needed to improve valve reliability. This study was based on a survey of the U.S. natural gas industry’s experience with line break control equipment, and upon computational modeling of typical pipeline systems to simulate the generation and propagation of pressure and flow transients created by a line break. Line break transients were also compared to the transient levels generated by normal pipeline operations (start-up and shutdown of compressors, branch load changes, etc.). Also during this study, a semi-empirical computer model was developed to calculate pipeline blowdown time as a function of break size, pipeline configuration, and operating conditions, even in cases where valve closure is delayed for some period after the line break occurs. This information can be of value to pipeline engineers and emergency response planners. Results of the technology assessment show that the primary source of unreliability in present day line break control systems lies in their inability to discriminate between a line break transient, and those generated by other pipeline operations. In most cases, automatic control valves (ACV’s) sense the rate of pipeline pressure drop (ROPD) to detect a line break. In many field applications, however, transient pressure signals caused by compressor operations and load changes are stronger than those produced by a line break. In order to avoid false valve closures which could otherwise result, sensitivity of the rupture detection systems is “backed off,” often to the point of inoperability of the ACV. Other fluid transient signals besides pressure drop are also generated in the pipeline during a line break, and these can sometimes be used advantageously to replace or confirm the traditional ROPD signal. In looped parallel pipelines, for example, crossover flow rate is usually a more reliable line break signal when crossovers are open. The resultant line-to-line differential pressure also provides a viable option when crossovers are either open or closed. In general, however, no one detection parameter is optimum for all applications. Of even more importance is the rupture sensor location. The concept of locating additional sensors between the main line valves (rather than just at the valves) provides the most promising approach for enhancing the reliability of present ACV’s and for providing needed line break information to remote controlled valves (RCV’s). In either case (ACV’s or RCV’s), rupture sensor location is much more important than valve location or valve spacing in ensuring reliable rupture isolation. However, valve spacing does affect the volume of gas blown down after shut-in of a ruptured section. This time can often be from 10 to 60 minutes for typical pipeline valve spacings.


2007 ◽  
Vol 04 (02) ◽  
pp. 171-190 ◽  
Author(s):  
JOANNE G. PHILLIPS ◽  
TED R. HEIDRICK ◽  
IAN J. POTTER

Futures Analysis Methodologies are reviewed and assessed to determine the most appropriate methodology for assessing the future value of a current investment in a sustainable energy technology. Assessment criteria are defined and each method is evaluated against these criteria. The paper provides preliminary conclusions regarding which methodologies to pursue for the purpose of developing a model to predict the future value of a current energy/environmental technology.


2008 ◽  
Vol 19 (4) ◽  
pp. 253-269 ◽  
Author(s):  
Sabine Heel ◽  
Sonja Fischer ◽  
Stefan Fischer ◽  
Tobias Grässer ◽  
Ellen Hämmerling ◽  
...  

Zunächst führt dieser Artikel in die wesentlichen Begrifflichkeiten und Zielstellungen der Versorgungsforschung ein. Er befasst sich dann mit der Frage, wie die einzelnen Teildisziplinen der Versorgungsforschung, (1) die Bedarfsforschung, (2) die Inanspruchnahmeforschung, (3) die Organisationsforschung, (4) das Health Technology Assessment, (5) die Versorgungsökonomie, (6) die Qualitätsforschung und zuletzt (7) die Versorgungsepidemiologie konzeptionell zu fassen sind, und wie sie für neuropsychologische Anliegen ausformuliert werden müssen. In diesem Zusammenhang werden die in den einzelnen Bereichen jeweils vorliegenden versorgungsrelevanten Studienergebnisse referiert. Soweit es zulässig ist, werden Bedarfe für die Versorgungsforschung und Versorgungspraxis in der Neurorehabilitation daraus abgeleitet und Anregungen für die weitere empirische Forschung formuliert. Der Artikel bezieht sich – entsprechend seines Anliegens – ausschließlich auf Studien, die sich mit der Situation der deutschen Neurorehabilitation befassen.


Sign in / Sign up

Export Citation Format

Share Document