scholarly journals THE EFFICIENCY OF REMOVING ORGANIC MATTERS AND COLOUR FROM GROUDWATER USING COAGULIANTS / ORGANINIŲ JUNGINIŲ IR SPALVOS ŠALINIMO IŠ POŽEMINIO VANDENS EFEKTYVUMAS NAUDOJANT KOAGULIANTUS

2011 ◽  
Vol 3 (5) ◽  
pp. 118-122
Author(s):  
Ramunė Albrektienė ◽  
Mindaugas Rimeika

Organic matter in drinking water must be removed as it causes many problems such as changes in colour, taste, odour and lower quality of water. During the chlorination process, humic acid reacts with chlorine and produce toxic disinfection-by-products. The study has used three coagulants: polialuminium oxychloride (PAC), aluminum sulphate and iron (III) chloride. The paper presents the outcomes of removing organic compounds from groundwater, investigates the decolourisation process and discusses pH impact on removing organic compounds and water colour. Aluminum based coagulants have been found to be the most effective regents. pH values have also a very significant impact on the effectiveness of the water coagulation process. Santrauka Organinius junginius iš geriamojo vandens šalinti būtina, nes jie suteikia vandeniui spalvą, vanduo įgyja nemalonų skonį ir kvapą. Organinės medžiagos mažina vandens ruošimo procesų efektyvumą ir reaguodamos su dezinfekcinėmis medžiagomis sudaro antrinius dezinfekcijos produktus, kurie yra toksiški. Šiame straipsnyje nagrinėjamas organinių junginių šalinimo iš požeminio vandens ir vandens spalvos mažinimo efektyvumas naudojant koaguliacijos procesą. Aptariama, kokią įtaką organiniams junginiams šalinti ir spalvos intensyvumui mažinti turi vandens pH vertės. Tiriant buvo naudojami trys koaguliantai: polialiuminio oksichloridas, aliuminio sulfatas ir geležies chloridas. Atlikus tyrimus nustatyta, kad efektyviausiai organinius junginius šalina aliuminio sulfatas ir polialiuminio oksichloridas. Naudojant aliuminio sulfatą, vandens spalvos intensyvumas sumažinamas 83 %, o organinės medžiagos – 85 %. Nustatyta, kad didinant koaguliantų dozes mažėja vandens pH vertės, o tai didina likutinio aliuminio koncentraciją ir blogina koaguliacijos procesą.

Author(s):  
Francesca Serio ◽  
Lucia Martella ◽  
Giovanni Imbriani ◽  
Adele Idolo ◽  
Francesco Bagordo ◽  
...  

Background: The quality of water for human consumption is an objective of fundamental importance for the defense of public health. Since the management of networks involves many problems of control and efficiency of distribution, the Water Safety Plan (WSP) was introduced to address these growing problems. Methods: WSP was applied to three companies in which the water resource assumes central importance: five water kiosks, a third-range vegetable processing company, and a residence and care institution. In drafting the plan, the terms and procedures designed and tested for the management of urban distribution systems were applied to safeguard the resource over time. Results: The case studies demonstrated the reliability of the application of the model even to small drinking-water systems, even though it involved a greater effort in analyzing the incoming water, the local intended use, and the possibilities for managing the containment of the dangers to which it is exposed. This approach demonstrates concrete effectiveness in identifying and mitigating the dangers of altering the quality of water. Conclusions: Thanks to the WSP applied to small drinking-water systems, we can move from management that is focused mainly on verifying the conformity of the finished product to the creation of a global risk assessment and management system that covers the entire water supply chain.


Author(s):  
В.А. Гвоздев ◽  
Л.В. Леонов ◽  
О.Н. Рублевская

Качество услуг водоснабжения и водоотведения за первые двадцать лет XXI века вывело на новый уровень развития ГУП «Водоканал Санкт-Петербурга» благодаря внедрению инновационных технологий в системах водоснабжения и водоотведения. Использование технологий, таких как двухступенчатое обеззараживание питьевой воды, дезодорирование полигонов, геотубирование, применение центрифуг «Флоттвег», порошкообразного однокомпонентного флокулянта, порошкообразного активированного угля, внедрение системы измерения осадков, осуществлялись при активном участии Федора Ивановича Лобанова – помощника генерального директора ГУП «Водоканал Санкт-Петербурга» по работе с промышленностью, которому в ноябре 2021 г. исполнилось 80 лет. The quality of water supply and wastewater disposal services over the first twenty years of the 21st century has brought SUE «Vodokanal of St. Petersburg» to a new level of development owing to the introduction of innovative technologies in water supply and wastewater disposal systems. The use of technologies, such as two-stage disinfection of drinking water, odor control of landfills, geotubing, the use of Flottweg centrifuges, powdered one-component flocculant, powdered activated carbon, the introduction of a precipitation measurement system, were carried out with the active participation of Fedor Ivanovich Lobanov, Assistant to the General Director of SUE «Vodokanal of St. Petersburg» on dealing with industries, who turned 80 in November 2021.


2015 ◽  
Vol 9 (08) ◽  
pp. 844-848 ◽  
Author(s):  
Sita Malhotra ◽  
Shailpreet K Sidhu ◽  
Pushpa Devi

Introduction: Safe water is a precondition for health and development and is a basic human right, yet it is still denied to hundreds of millions of people throughout the developing world. Water-related diseases caused by insufficient safe water supplies, coupled with poor sanitation and hygiene, cause 3.4 million deaths a year, mostly in children. Methodology: The present study was conducted on 1,317 drinking water samples from various water sources in Amritsar district in northern India. All the samples were analyzed to assess bacteriological quality of water for presumptive coliform count by the multiple tube test. Results: A total of 42.9% (565/1,317) samples from various sources were found to be unfit for human consumption. Of the total 565 unsatisfactory samples, 253 were from submersible pumps, 197 were from taps of piped supply (domestic/public), 79 were from hand pumps, and 36 were from various other sources A significantly high level of contamination was observed in samples collected from submersible pumps (47.6%) and water tanks (47.3%), as these sources of water are more exposed and liable to contamination. Conclusions: Despite continuous efforts by the government, civil society, and the international community, over a billion people still do not have access to improved water resources. Bacteriological assessment of all sources of drinking should be planned and conducted on regular basis to prevent waterborne dissemination of diseases.


2009 ◽  
Vol 168 (2-3) ◽  
pp. 753-759 ◽  
Author(s):  
Lingling Zhang ◽  
Ping Gu ◽  
Zijie Zhong ◽  
Dong Yang ◽  
Wenjie He ◽  
...  

Water ◽  
2019 ◽  
Vol 11 (10) ◽  
pp. 2166
Author(s):  
Wang ◽  
Zhao ◽  
Chen ◽  
Zhao

The chemical composition of river water collected from the main stream of the Naqu and its tributaries was analyzed to reveal its hydrochemical characteristics and to evaluate the water quality for irrigation purposes. Based on 39 samples, the results revealed mildly alkaline pH values and total dissolved solids (TDS) values ranging from 115 to 676 mg/L, averaging 271 mg/L. Major ion concentrations based on mean values (mg/L) were in the order of Ca2+>Na+>Mg2+>K+ for cations and HCO3->SO42->Cl->CO32- for anions. Most hydrochemical types were of the Ca–HCO3 (~74.36%) type. Cluster analysis (CA) suggested that the hydrochemical characteristics upstream of the main stream of the Naqu were obviously different from those from the middle and downstream of the main stream and its tributaries. The analysis shows that the Sangqu, Basuoqu, Mumuqu, Zongqingqu, Mugequ basin tributary, and the Gongqu basin tributary were mainly affected by carbonate weathering. Carbonate and silicate weathering commonly controlled the hydrochemistry upstream and downstream of the main Naqu, Chengqu, and Mugequ streams. The middle of the main stream of the Naqu was mainly affected by silicate weathering, and anhydrite/gypsum dissolution mainly affected the hydrochemistry of the main Gongqu stream. The quality of water samples was suitable for irrigation purposes, except for one sample from the main stream of the Mugequ.


Water ◽  
2018 ◽  
Vol 10 (9) ◽  
pp. 1164 ◽  
Author(s):  
Assia Mokssit ◽  
Bernard de Gouvello ◽  
Aurélie Chazerain ◽  
François Figuères ◽  
Bruno Tassin

This document proposes a methodology for assessing the quality of water distribution service in the context of intermittent supply, based on a comparison of joint results from literature reviews and feedback from drinking water operators who had managed these networks, with standards for defining the quality of drinking water service. The paper begins by reviewing and proposing an analysis of the definition and characterization of intermittent water supply (IWS), highlighting some important findings. The diversity of approaches used to address the issue and the difficulty of defining a precise and detailed history of water supply in the affected systems broadens the spectrum of intermittency characterization and the problems it raises. The underlined results are then used to structure an evaluation framework for the water service and to develop improvement paths defined in the intermittent networks. The resulting framework highlights the means available to water stakeholders to assess their operational and management performance in achieving the improvement objectives defined by the environmental and socio-economic contexts in which the network operates. Practical examples of intermittent system management are collected from water system operators and presented for illustration purposes (Jeddah, Algiers, Port-au-Prince, Amman, Cartagena, Barranquilla, Mexico, Cancun, Saltillo, Mumbai, Delhi, Coimbatore …).


2011 ◽  
Vol 42 (2) ◽  
pp. 560-566 ◽  
Author(s):  
Maria Tereza Pepe Razzolini ◽  
Wanda Maria Risso Günther ◽  
Francisca Alzira dos Santos Peternella ◽  
Solange Martone-Rocha ◽  
Veridiana Karmann Bastos ◽  
...  

2020 ◽  
Vol 841 ◽  
pp. 36-40
Author(s):  
Mardan Jalilov ◽  
Ayten Jalilova ◽  
Gulnar Feyziyeva ◽  
Makhanim Azimova

Given that the quality of water supplied to hot water supply systems must meet drinking water requirements, it is also important that the water preparation process is of great importance. The quality of that water is also important in terms of preventing the formation of heat in hot water systems. It is known that the main cause of the formation of water is the presence of calcium and magnesium cations and bicarbonate and sulfate anions in water. The traditional methods for preventing the limescale include the combination of calcium and magnesium cations from the water and replacing them with cations that are not easy to resolve at high temperatures. The quality of water treated by these methods does not meet drinking water requirements. Taking these into account, the Cl-anionizationprocess of drinking water has been developed in high-tech anionite technology. According to this technology, the first water from the city water gridis processed through anionite and activated carbon filters, which are mechanically charged with high anionite. The treated water is then cleaned out of microbes and bacteria through the ultraviolet disinfection equipment and delivered to the operator according to the quality requirements for drinking water. In the chlorine-anionization process, most of the sulfate and bicarbonate anions in water change to chlorine anions and their solidity remains constant. Thus, the density of the limescale-forming anions in the water decreases sharply and it meets the quality indicators of drinking water. High-grade anionite in the filter (8÷12) is regenerated by NaCl solution. The filtration rate of the solution from the anionite is determined depending on the concentration of calcium cations contained in the salt given for regeneration. Regeneration mode is such that the CaCO3 combination does not crumble when the anionite layer is formed. It is known that the temperature of the heated water in the hot water supply system does not exceed (60÷70)°C. In this case, the decomposition of limescale at Hc<2 mg-eq/l (carbonate hardness) is not observed. As carbonate hardness increases to 4 mg/l, the thin layer in the system shows a collapse. The basic element of the proposed technological schemeCl-anionite filter was applied at ADA University in Baku and positive results were obtained. Early observed collapse of pipes has been prevented and the working regime of hot water heaters has improved. A high-performance anionite such as A200EMBCl, which is a major ingredient of the UK's Purelite, and then the Russian-made AB-17-8 high-anionite anions have been used on the device.


Sign in / Sign up

Export Citation Format

Share Document