Creating the Evidence: Lessons from Cochlear Implants

2005 ◽  
Vol 16 (07) ◽  
pp. 515-522 ◽  
Author(s):  
David Fabry

This paper compares the evidence-based outcomes between cochlear implants and hearing aids during the past several decades. Despite many similarities, there are also some important differences that define the progress for the two disciplines. Perhaps the most significant distinction exists in terms of the difference between the Food and Drug Administration's treatment of hearing aids as Class I medical devices, while cochlear implants are defined as Class III devices. Another point of divergence has been the number of publications in archival, peer-reviewed journals; implant papers have been steadily increasing during the past decade, while hearing aid papers have declined during the same period. The impact of these differences on the past, present, and future of hearing aid and cochlear implant research, technology, and clinical practice is discussed.

2020 ◽  
Vol 41 (04) ◽  
pp. 254-265
Author(s):  
David W. Maidment ◽  
Amyn M. Amlani

AbstractIn this article, we review the current literature assessing the application and benefits of connected hearing technologies, as well as their potential to improve accessibility to and affordability of hearing healthcare. Over the past decade, there has been a proliferation of hearing devices that connect wirelessly to smartphone technologies via Bluetooth. These devices include (1) smartphone-connected hearing aids that must be obtained from a licensed audiologist or hearing aid dispenser; (2) direct-to-consumer devices, such as personal sound amplification products; and (3) smartphone-based hearing aid applications (or apps). Common to all these connected devices is that they permit the user to self-adjust and customize their device programs via an accompanying smartphone app. There has been a growing body of literature assessing connected hearing devices in adults living with hearing loss. Overall, the evidence to date supports the notion that all connected hearing devices can improve accessibility to and affordability of amplification. It is unclear, however, whether connected technologies are a clinically effective alternative to traditional hearing aids. Even so, the impact of connectivity is especially pertinent given the sudden disruption caused by the recent global COVID-19 pandemic, whereby connected technologies enable patients to receive treatment through mobile-based, tele-audiology platforms.


1989 ◽  
Vol 8 (1) ◽  
pp. 81-92
Author(s):  
Thomas J. Maronick ◽  
Sandra E. Gleason ◽  
M. Ronald Stiff

A consumer mail panel was used to locate persons who had purchased a hearing aid within the past two years in order to determine the relationship between price paid, and overall satisfaction as a function of use by a physician, an audiologist, or a dealer as the provider to services related to the purchase. A total of 874 consumers, 78 percent of whom were over age 60, completed the written questionnaire. Overall, 83 percent of the survey respondents were satisfied with their most recent hearing aid purchase. Those who consulted a physician for a medical exam prior to being fitted for and purchasing a hearing aid were slightly more satisfied than those who did not consult a physician (85 percent versus 80 percent). Consumers were most satisfied when they were fitted for and bought their hearing aid from an audiologist. The least satisfied respondents were those consumers who used hearing aid dealers or salespersons rather than physicians or audiologists. The most expensive hearing aids were sold by the least well trained providers, hearing aid dealers and salespersons. Herein, implications for public policy in terms of access to hearing aids by the elderly and level of training are discussed.


2019 ◽  
Vol 28 (4) ◽  
pp. 877-894
Author(s):  
Nur Azyani Amri ◽  
Tian Kar Quar ◽  
Foong Yen Chong

Purpose This study examined the current pediatric amplification practice with an emphasis on hearing aid verification using probe microphone measurement (PMM), among audiologists in Klang Valley, Malaysia. Frequency of practice, access to PMM system, practiced protocols, barriers, and perception toward the benefits of PMM were identified through a survey. Method A questionnaire was distributed to and filled in by the audiologists who provided pediatric amplification service in Klang Valley, Malaysia. One hundred eight ( N = 108) audiologists, composed of 90.3% women and 9.7% men (age range: 23–48 years), participated in the survey. Results PMM was not a clinical routine practiced by a majority of the audiologists, despite its recognition as the best clinical practice that should be incorporated into protocols for fitting hearing aids in children. Variations in practice existed warranting further steps to improve the current practice for children with hearing impairment. The lack of access to PMM equipment was 1 major barrier for the audiologists to practice real-ear verification. Practitioners' characteristics such as time constraints, low confidence, and knowledge levels were also identified as barriers that impede the uptake of the evidence-based practice. Conclusions The implementation of PMM in clinical practice remains a challenge to the audiology profession. A knowledge-transfer approach that takes into consideration the barriers and involves effective collaboration or engagement between the knowledge providers and potential stakeholders is required to promote the clinical application of evidence-based best practice.


2008 ◽  
Vol 18 (1) ◽  
pp. 4-9 ◽  
Author(s):  
Leisha Eiten ◽  
Dawna Lewis

Background: For children with hearing loss, the benefits of FM systems in overcoming deleterious effects of noise, distance, and reverberation have led to recommendations for use beyond classroom settings. It is important that audiologists who recommend and fit these devices understand the rationale and procedures underlying fitting and verification. Objectives: This article reviews previousguidelines for FM verification, addresses technological advances, and introduces verification procedures appropriate for current FM and hearing-aid technology. Methods: Previous guidelines for verification of FM systems are reviewed. Those recommendations that are appropriate for current technology are addressed, as are procedures that are no longer adequate for hearing aids and FM systems utilizing more complex processing than in the past. Technological advances are discussed, and an updated approach to FM verification is proposed. Conclusions: Approaches to verification andfitting of FM systems must keep pace with advances in hearing-aid and FM technology. The transparency approach addressed in this paper is recommended for verification of FM systems coupled to hearing aids.


1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


2021 ◽  
Vol 11 (2) ◽  
pp. 200-206
Author(s):  
Gennaro Auletta ◽  
Annamaria Franzè ◽  
Carla Laria ◽  
Carmine Piccolo ◽  
Carmine Papa ◽  
...  

Background: The aim of this study was to compare, in users of bimodal cochlear implants, the performance obtained using their own hearing aids (adjusted with the standard NAL-NL1 fitting formula) with the performance using the Phonak Naìda Link Ultra Power hearing aid adjusted with both NAL-NL1 and a new bimodal system (Adaptive Phonak Digital Bimodal (APDB)) developed by Advanced Bionics and Phonak Corporations. Methods: Eleven bimodal users (Naìda CI Q70 + contralateral hearing aid) were enrolled in our study. The users’ own hearing aids were replaced with the Phonak Naìda Link Ultra Power and fitted following the new formula. Speech intelligibility was assessed in quiet and noisy conditions, and comparisons were made with the results obtained with the users’ previous hearing aids and with the Naída Link hearing aids fitted with the NAL-NL1 generic prescription formula. Results: Using Phonak Naìda Link Ultra Power hearing aids with the Adaptive Phonak Digital Bimodal fitting formula, performance was significantly better than that with the users’ own rehabilitation systems, especially in challenging hearing situations for all analyzed subjects. Conclusions: Speech intelligibility tests in quiet settings did not reveal a significant difference in performance between the new fitting formula and NAL-NL1 fittings (using the Naída Link hearing aids), whereas the performance difference between the two fittings was very significant in noisy test conditions.


Author(s):  
Yu-Hsiang Wu ◽  
Elizabeth Stangl ◽  
Octav Chipara ◽  
Anna Gudjonsdottir ◽  
Jacob Oleson ◽  
...  

Abstract Background Ecological momentary assessment (EMA) is a methodology involving repeated surveys to collect in-situ self-reports that describe respondents' current or recent experiences. Audiology literature comparing in-situ and retrospective self-reports is scarce. Purpose To compare the sensitivity of in-situ and retrospective self-reports in detecting the outcome difference between hearing aid technologies, and to determine the association between in-situ and retrospective self-reports. Research Design An observational study. Study Sample Thirty-nine older adults with hearing loss. Data Collection and Analysis The study was part of a larger clinical trial that compared the outcomes of a prototype hearing aid (denoted as HA1) and a commercially available device (HA2). In each trial condition, participants wore hearing aids for 4 weeks. Outcomes were measured using EMA and retrospective questionnaires. To ensure that the outcome data could be directly compared, the Glasgow Hearing Aid Benefit Profile was administered as an in-situ self-report (denoted as EMA-GHABP) and as a retrospective questionnaire (retro-GHABP). Linear mixed models were used to determine if the EMA- and retro-GHABP could detect the outcome difference between HA1 and HA2. Correlation analyses were used to examine the association between EMA- and retro-GHABP. Results For the EMA-GHABP, HA2 had significantly higher (better) scores than HA1 in the GHABP subscales of benefit, residual disability, and satisfaction (p = 0.029–0.0015). In contrast, the difference in the retro-GHABP score between HA1 and HA2 was significant only in the satisfaction subscale (p = 0.0004). The correlations between the EMA- and retro-GHABP were significant in all subscales (p = 0.0004 to <0.0001). The strength of the association ranged from weak to moderate (r = 0.28–0.58). Finally, the exit interview indicated that 29 participants (74.4%) preferred HA2 over HA1. Conclusion The study suggests that in-situ self-reports collected using EMA could have a higher sensitivity than retrospective questionnaires. Therefore, EMA is worth considering in clinical trials that aim to compare the outcomes of different hearing aid technologies. The weak to moderate association between in-situ and retrospective self-reports suggests that these two types of measures assess different aspects of hearing aid outcomes.


2009 ◽  
Vol 20 (05) ◽  
pp. 320-334 ◽  
Author(s):  
Gabrielle H. Saunders ◽  
M Samantha Lewis ◽  
Anna Forsline

Background: Data suggest that having high expectations about hearing aids results in better overall outcome. However, some have postulated that excessively high expectations will result in disappointment and thus poor outcome. It has been suggested that counseling patients with unrealistic expectations about hearing aids prior to fitting may be beneficial. Data, however, are mixed as to the effectiveness of such counseling, in terms of both changes in expectations and final outcome. Purpose: The primary purpose of this study was to determine whether supplementing prefitting counseling with demonstration of real-world listening can (1) alter expectations of new hearing aid users and (2) increase satisfaction over verbal-only counseling. Secondary goals of the study were to examine (1) the relationship between prefitting expectations and postfitting outcome, and (2) the effect of hearing aid fine-tuning on hearing aid outcome. Research Design: Sixty new hearing aid users were fitted binaurally with Beltone Oria behind-the-ear digital hearing aids. Forty participants received prefitting counseling and demonstration of listening situations with the Beltone AVE™ (Audio Verification Environment) system; 20 received prefitting counseling without a demonstration of listening situations. Hearing aid expectations were measured at initial contact and following prefitting counseling. Reported hearing aid outcome was measured after eight to ten weeks of hearing aid use. Study Sample: Sixty new hearing aid users aged between 55 and 81 years with symmetrical sensorineural hearing loss. Intervention: Participants were randomly assigned to one of three experimental groups, between which the prefitting counseling and follow-up differed: Group 1 received prefitting counseling in combination with demonstration of listening situations. Additionally, if the participant had complaints about sound quality at the follow-up visit, the hearing aids were fine-tuned using the Beltone AVE system. Group 2 received prefitting counseling in combination with demonstration of listening situations with the Beltone AVE system, but no fine-tuning was provided at follow-up. Group 3 received prefitting hearing aid counseling that did not include demonstration of listening, and the hearing aids were not fine-tuned at the follow-up appointment. Results: The results showed that prefitting hearing aid counseling had small but significant effects on expectations. The two forms of counseling did not differ in their effectiveness at changing expectations; however, anecdotally, we learned from many participants that that they enjoyed listening to the auditory demonstrations and that they found them to be an interesting listening exercise. The data also show that positive expectations result in more positive outcome and that hearing aid fine-tuning is beneficial to the user. Conclusions: We conclude that prefitting counseling can be advantageous to hearing aid outcome and recommend the addition of prefitting counseling to address expectations associated with quality of life and self-image. The data emphasize the need to address unrealistic expectations prior to fitting hearing aids cautiously, so as not to decrease expectations to the extent of discouraging and demotivating the patient. Data also show that positive expectations regarding the impact hearing aids will have on psychosocial well-being are important for successful hearing aid outcome.


1993 ◽  
Vol 102 (6) ◽  
pp. 433-437 ◽  
Author(s):  
Mark A. Frattali ◽  
Robert T. Sataloff

Profound deafness has received increasing attention in recent years, largely because of the availability of cochlear implants. Consequently, it is especially important for otolaryngologists to remember that a “blank” audiogram does not necessarily mean total or even profound deafness. Patients with far-advanced otosclerosis may have no measurable hearing with routine audiometric testing even in the presence of serviceable sensorineural hearing. Review of nine patients (10 ears) who underwent stapedectomy from 1980 to 1987 reveals that seven of the nine (78%), who had been unable to use a hearing aid preoperatively, obtained serviceable hearing with hearing aids following surgery. Otolaryngologists should depend on a good history and tuning fork examination to avoid being misled by the audiogram, and should not hesitate to offer stapes surgery to patients with far-advanced otosclerosis.


2015 ◽  
Vol 22 (03) ◽  
pp. 26-45
Author(s):  
Bon Nguyen Van

Foreign direct investment (FDI) has been strongly affecting the world economy during the past years and is a critical topic for both developing and developed countries. Most countries, particularly developing ones, always attempt to adjust and modify appropriate policies and institutions to attract FDI inflows. In the context of Vietnam, does the institutional quality have any effect on attracting FDI inflows in provinces? To answer clearly and exactly this question, the impact of institutional quality on attracting FDI inflows is empirically investigated in a sample of 43 provinces of Vietnam over the period of 2005–2012 via the estimation technique of difference panel GMM. Estimated results indicate that in the total sample of all provinces the institutional quality has significantly positive effects on the FDI flows. However, in the sub-sample of provinces the impact of the institutional quality on attracting FDI inflows in Northern and Southern regions are statistically significant while that in Central region is not.


Sign in / Sign up

Export Citation Format

Share Document