scholarly journals Spatial Distortion Assessments of a Low-Cost Laboratory and Field Hyperspectral Imaging System

Sensors ◽  
2019 ◽  
Vol 19 (19) ◽  
pp. 4267
Author(s):  
Andrija Krtalić ◽  
Vanja Miljković ◽  
Dubravko Gajski ◽  
Ivan Racetin

This article describes the adaptation of an existing aerial hyperspectral imaging system in a low-cost setup for collecting hyperspectral data in laboratory and field environment and spatial distortion assessments. The imaging spectrometer system consists of an ImSpector V9 hyperspectral pushbroom scanner, PixelFly high performance digital CCD camera, and a subsystem for navigation, position determination and orientation of the system in space, a sensor bracket and control system. The main objective of the paper is to present the system, with all its limitations, and a spatial calibration method. The results of spatial calibration and calculation of modulation transfer function (MTF) are reported along with examples of images collected and potential uses in agronomy. The distortion value rises drastically at the edges of the image in the near-infrared segment, while the results of MTF calculation showed that the image sharpness was equal for the bands from the visible part of the spectrum, and approached Nyquist’s theory of digitalization. In the near-infrared part of the spectrum, the MTF values showed a less sharp decrease in comparison with the visible part. Preliminary image acquisition indicates that this hyperspectral system has potential in agronomic applications.

Author(s):  
Sami D. Alaruri

A low-cost CCD camera system for imaging Coulter orifices ranging in diameter between 20 µm and 2 mm has been developed and tested. The imaging system incorporates a 6X magnifying lens for viewing the required range of Coulter orifices and LEDs (Light emitting diodes) lamp for back illuminating the orifices. Geometric optic calculations using Zemax® for the micro-lens interfaced with the camera suggest that the spot diameter and the MTF spatial frequency at field of view equal to 0 ° and at the image plane are 5.13 µm and 271.6 lines/mm (at contrast= 37.6%), respectively. Images captured with the camera system for 20 µm, 100 µm and 2 mm diameter orifices are provided. Furthermore, a discussion for the camera micro-lens modulation transfer function, spot diagram, root-mean-square wavefront error versus field and optical path difference plots is given.


2003 ◽  
Vol 11 (4) ◽  
pp. 269-281 ◽  
Author(s):  
Kurt C. Lawrence ◽  
William R. Windham ◽  
Bosoon Park ◽  
R. Jeff Buhr

A method and system for detecting faecal and ingesta contaminants on poultry carcasses were demonstrated. A visible/near infrared monochromator, which measured reflectance and principal component analysis were first used to identify key wavelengths from faecal and uncontaminated skin samples. Measurements at 434, 517, 565 and 628 nm were identified and used for evaluation with a hyperspectral imaging system. The hyperspectral imaging system, which was a line-scan (pushbroom) imaging system, consisted of a hyperspectral camera, fibre-optic line lights, a computer and frame grabber. The hyperspectral imaging camera consisted of a high-resolution charge coupled device (CCD) camera, a prism-grating-prism spectrograph, focusing lens, associated optical hardware and a motorised controller. The imaging system operated from about 400 to 900 nm. The hyperspectral imaging system was calibrated for wavelength, distance and percent reflectance and analysis of calibrated images at the key wavelengths indicated that single-wavelength images were inadequate for detecting contaminants. However, a ratio of images at two of the key wavelengths was able to identify faecal and ingesta contaminants. Specifically, the ratio of the 565-nm image divided by the 517-nm image produced good results. The ratio image was then further processed by masking the background and either enhancing the image contrast with a non-linear histogram stretch, or applying a faecal threshold. The results indicated that, for the limited sample population, more than 96% of the contaminants were detected. Thus, the hyperspectral imaging system was able to detect contaminants and showed feasibility, but was too slow for real-time on-line processing. Therefore, a multivariate system operating at 565 and 517 nm, which should be capable of operating at real-time on-line processing speed, should be used. Further research with such a system needs to be conducted.


2021 ◽  
Vol 7 (8) ◽  
pp. 136
Author(s):  
Mary B. Stuart ◽  
Andrew J. S. McGonigle ◽  
Matthew Davies ◽  
Matthew J. Hobbs ◽  
Nicholas A. Boone ◽  
...  

Recent advances in smartphone technologies have opened the door to the development of accessible, highly portable sensing tools capable of accurate and reliable data collection in a range of environmental settings. In this article, we introduce a low-cost smartphone-based hyperspectral imaging system that can convert a standard smartphone camera into a visible wavelength hyperspectral sensor for ca. £100. To the best of our knowledge, this represents the first smartphone capable of hyperspectral data collection without the need for extensive post processing. The Hyperspectral Smartphone’s abilities are tested in a variety of environmental applications and its capabilities directly compared to the laboratory-based analogue from our previous research, as well as the wider existing literature. The Hyperspectral Smartphone is capable of accurate, laboratory- and field-based hyperspectral data collection, demonstrating the significant promise of both this device and smartphone-based hyperspectral imaging as a whole.


Sensors ◽  
2021 ◽  
Vol 21 (13) ◽  
pp. 4436
Author(s):  
Mohammad Al Ktash ◽  
Mona Stefanakis ◽  
Barbara Boldrini ◽  
Edwin Ostertag ◽  
Marc Brecht

A laboratory prototype for hyperspectral imaging in ultra-violet (UV) region from 225 to 400 nm was developed and used to rapidly characterize active pharmaceutical ingredients (API) in tablets. The APIs are ibuprofen (IBU), acetylsalicylic acid (ASA) and paracetamol (PAR). Two sample sets were used for a comparison purpose. Sample set one comprises tablets of 100% API and sample set two consists of commercially available painkiller tablets. Reference measurements were performed on the pure APIs in liquid solutions (transmission) and in solid phase (reflection) using a commercial UV spectrometer. The spectroscopic part of the prototype is based on a pushbroom imager that contains a spectrograph and charge-coupled device (CCD) camera. The tablets were scanned on a conveyor belt that is positioned inside a tunnel made of polytetrafluoroethylene (PTFE) in order to increase the homogeneity of illumination at the sample position. Principal component analysis (PCA) was used to differentiate the hyperspectral data of the drug samples. The first two PCs are sufficient to completely separate all samples. The rugged design of the prototype opens new possibilities for further development of this technique towards real large-scale application.


2022 ◽  
Vol 15 (2) ◽  
pp. 027001
Author(s):  
Yang Cui ◽  
Taiki Takamatsu ◽  
Koichi Shimizu ◽  
Takeo Miyake

Abstract As for the diagnosis and treatment of eye diseases, an ideal fundus imaging system is expected to be portability, low cost, and high resolution. Here, we demonstrate a non-mydriatic near-infrared fundus imaging system with light illumination from an electronic contact lens (E-lens). The E-lens can illuminate the retinal and choroidal structures for capturing the fundus images when voltage is applied wirelessly to the lens. And we also reconstruct the images with a depth-dependent point-spread function to suppress the scattering effect that eventually visualizes the clear fundus images.


2018 ◽  
Vol 8 (12) ◽  
pp. 2602 ◽  
Author(s):  
Laurence Schimleck ◽  
Joseph Dahlen ◽  
Seung-Chul Yoon ◽  
Kurt Lawrence ◽  
Paul Jones

Near-infrared (NIR) spectroscopy and NIR hyperspectral imaging (NIR-HSI) were compared for the rapid estimation of physical and mechanical properties of No. 2 visual grade 2 × 4 (38.1 mm by 88.9 mm) Douglas-fir structural lumber. In total, 390 lumber samples were acquired from four mills in North America and destructively tested through bending. From each piece of lumber, a 25-mm length block was cut to collect diffuse reflectance NIR spectra and hyperspectral images. Calibrations for the specific gravity (SG) of both the lumber (SGlumber) and 25-mm block (SGblock) and the lumber modulus of elasticity (MOE) and modulus of rupture (MOR) were created using partial least squares (PLS) regression and their performance checked with a prediction set. The strongest calibrations were based on NIR spectra; however, the NIR-HSI data provided stronger predictions for all properties. In terms of fit statistics, SGblock gave the best results, followed by SGlumber, MOE, and MOR. The NIR-HSI SGlumber, MOE, and MOR calibrations were used to predict these properties for each pixel across the transverse surface of the scanned samples, allowing SG, MOE, and MOR variation within and among rings to be observed.


Author(s):  
Laura M. DALE ◽  
André THEWIS ◽  
Ioan ROTAR ◽  
Juan A. FERNANDEZ PIERNA ◽  
Christelle BOUDRY ◽  
...  

Nowadays in agriculture, new analytical tools based on spectroscopic technologies are developed. Near Infrared Spectroscopy (NIRS) is a well known technology in the agricultural sector allowing the acquisition of chemical information from the samples with a large number of advantages, such as: easy to use tool, fast and simultaneous analysis of several components, non-polluting, noninvasive and non destructive technology, and possibility of online or field implementation. Recently, NIRS system was combined with imaging technologies creating the Near Infrared Hyperspectral Imaging system (NIR-HSI). This technology provides simultaneously spectral and spatial information from an object. The main differences between NIR-HSI and NIRS is that many spectra can be recorded simultaneously from a large area of an object with the former while with NIRS only one spectrum was recorded for analysis on a small area. In this work, both technologies are presented with special focus on the main spectrum and images analysis methods. Several qualitative and quantitative applications of NIRS and NIR-HSI in agricultural products are listed. Developments of NIRS and NIR-HSI will enhance progress in the field of agriculture by providing high quality and safe agricultural products, better plant and grain selection techniques or compound feed industry’s productivity among others.


Sign in / Sign up

Export Citation Format

Share Document