scholarly journals Prediction of Douglas-Fir Lumber Properties: Comparison between a Benchtop Near-Infrared Spectrometer and Hyperspectral Imaging System

2018 ◽  
Vol 8 (12) ◽  
pp. 2602 ◽  
Author(s):  
Laurence Schimleck ◽  
Joseph Dahlen ◽  
Seung-Chul Yoon ◽  
Kurt Lawrence ◽  
Paul Jones

Near-infrared (NIR) spectroscopy and NIR hyperspectral imaging (NIR-HSI) were compared for the rapid estimation of physical and mechanical properties of No. 2 visual grade 2 × 4 (38.1 mm by 88.9 mm) Douglas-fir structural lumber. In total, 390 lumber samples were acquired from four mills in North America and destructively tested through bending. From each piece of lumber, a 25-mm length block was cut to collect diffuse reflectance NIR spectra and hyperspectral images. Calibrations for the specific gravity (SG) of both the lumber (SGlumber) and 25-mm block (SGblock) and the lumber modulus of elasticity (MOE) and modulus of rupture (MOR) were created using partial least squares (PLS) regression and their performance checked with a prediction set. The strongest calibrations were based on NIR spectra; however, the NIR-HSI data provided stronger predictions for all properties. In terms of fit statistics, SGblock gave the best results, followed by SGlumber, MOE, and MOR. The NIR-HSI SGlumber, MOE, and MOR calibrations were used to predict these properties for each pixel across the transverse surface of the scanned samples, allowing SG, MOE, and MOR variation within and among rings to be observed.

2011 ◽  
Vol 04 (02) ◽  
pp. 199-208
Author(s):  
ZHIQIU LI ◽  
SHUDONG JIANG ◽  
VENKATARAMANAN KRISHNASWAMY ◽  
SCOTT C. DAVIS ◽  
SUBHADRA SRINIVASAN ◽  
...  

A near-infrared (NIR) tomography system with spectrally-encoded sources in two wavelength bands was built to quantify the temporal oxyhemoglobin and deoxyhemoglobin contrast in breast tissue at a 20 Hz bandwidth. The system was integrated into a 3 T magnetic resonance (MR) imaging system through a customized breast coil interface for simultaneous optical and MRI acquisition. In this configuration, the MR images provide breast tissue structural information for NIR spectroscopy of adipose and fibro-glandular tissue in breast. Spectral characterization performance of the NIR system was verified through dynamic phantom experiments. Normal human subjects were imaged with finger pulse oximeter (PO) plethysmogram synchronized to the NIR system to provide a frequency-locked reference. Both the raw data from the NIR system and the recovered absorption coefficients of the breast at two wavelengths showed the same frequency of about 1.3 Hz as the PO output. The frequency lock-in approach provided a practical platform for MR-localized recovery of small pulsatile variations of oxyhemoglobin and deoxyhemoglobin in the breast, which are related to the heartbeat and vascular resistance of the tissue.


Author(s):  
Laura M. DALE ◽  
André THEWIS ◽  
Ioan ROTAR ◽  
Juan A. FERNANDEZ PIERNA ◽  
Christelle BOUDRY ◽  
...  

Nowadays in agriculture, new analytical tools based on spectroscopic technologies are developed. Near Infrared Spectroscopy (NIRS) is a well known technology in the agricultural sector allowing the acquisition of chemical information from the samples with a large number of advantages, such as: easy to use tool, fast and simultaneous analysis of several components, non-polluting, noninvasive and non destructive technology, and possibility of online or field implementation. Recently, NIRS system was combined with imaging technologies creating the Near Infrared Hyperspectral Imaging system (NIR-HSI). This technology provides simultaneously spectral and spatial information from an object. The main differences between NIR-HSI and NIRS is that many spectra can be recorded simultaneously from a large area of an object with the former while with NIRS only one spectrum was recorded for analysis on a small area. In this work, both technologies are presented with special focus on the main spectrum and images analysis methods. Several qualitative and quantitative applications of NIRS and NIR-HSI in agricultural products are listed. Developments of NIRS and NIR-HSI will enhance progress in the field of agriculture by providing high quality and safe agricultural products, better plant and grain selection techniques or compound feed industry’s productivity among others.


2001 ◽  
Vol 31 (10) ◽  
pp. 1671-1675 ◽  
Author(s):  
L R Schimleck ◽  
R Evans ◽  
J Ilic

The use of calibrated near infrared (NIR) spectroscopy for the prediction of a range solid wood properties is described. The methods developed are applicable to large-scale nondestructive forest resource assessment and to tree breeding and silvicultural programs. A series of Eucalyptus delegatensis R.T. Baker (alpine ash) samples were characterized in terms of density, longitudinal modulus of elasticity (EL), microfibril angle (MFA), and modulus of rupture (MOR). NIR spectra were obtained from the radial–longitudinal face of each sample and used to generate calibrations for the measured physical properties. The relationships were good in all cases, with coefficients of determination ranging from 0.77 for MOR through 0.90 for EL to 0.93 for stick density. In view of the rapidly expanding range of applications for this technique, it is concluded that appropriately calibrated NIR spectroscopy could form the basis of a "universal" testing instrument capable of predicting a wide range of product properties from a single type of spectrum obtained from the product or from the raw material.


2001 ◽  
Vol 7 (S2) ◽  
pp. 162-163
Author(s):  
EN Lewis ◽  
LH Kidder ◽  
KS Haber

Single point near-infrared (NIR) spectroscopy is used extensively for characterizing raw materials and finished products in a wide variety of industries: polymers, paper, film, pharmaceuticals, paintings and coatings, food and beverages, agricultural products. As advanced industrial materials become more complex, their functionality is often determined by the spatial distribution of their discrete sample constituents. However, conventional single point NIR spectroscopy cannot adequately probe the interrelationship between the spatial distribution of sample components with the physical properties of the sample. to fully characterize these samples, it is necessary to probe simultaneously spatial and chemical heterogeneity and correlate these properties with sample characteristics.Recently, we have developed a novel NIR imaging spectrometer that can deliver spatially resolved chemical information very rapidly. in contrast to conventional, single point NIR spectrometers, the imaging system uses an infrared focal-plane array (FPA) to collect up to 76,800 complete spectra, one for each pixel on the array, in approximately one minute.


2019 ◽  
Vol 8 (4) ◽  
pp. 21
Author(s):  
Aoife Power ◽  
Vi Khanh Truong ◽  
James Chapman ◽  
Daniel Cozzolino

Compared to traditional laboratory methods, spectroscopic techniques (e.g., near infrared, hyperspectral imaging) provide analysts with an innovative and improved understanding of complex issues by determining several chemical compounds and metabolites at once, allowing for the collection of the sample “fingerprint”. These techniques have the potential to deliver high-throughput options for the analysis of the chemical composition of grapes in the laboratory, the vineyard and before or during harvest, to provide better insights of the chemistry, nutrition and physiology of grapes. Faster computers, the development of software and portable easy to use spectrophotometers and data analytical methods allow for the development of innovative applications of these techniques for the analyses of grape composition.


2015 ◽  
Vol 73 (1) ◽  
Author(s):  
Feri Candra ◽  
Syed Abd. Rahman Abu Bakar

Hyperspectral imaging technology is a powerful tool for non-destructive quality assessment of fruits. The objective of this research was to develop novel calibration model based on hyperspectral imaging to estimate soluble solid content (SSC) of starfruits. A hyperspectral imaging system, which consists of a near infrared  camera, a spectrograph V10, a halogen lighting and a conveyor belt system, was used in this study to acquire hyperspectral  images of the samples in visible and near infrared (500-1000 nm) regions. Partial least square (PLS) was used to build the model and to find the optimal wavelength. Two different masks were applied for obtaining the spectral data. The optimal wavelengths were evaluated using multi linear regression (MLR). The coefficient of determination (R2) for validation using the model with first mask (M1) and second mask (M2) were 0.82 and 0.80, respectively.


2007 ◽  
Vol 79 (12) ◽  
pp. 4709-4715 ◽  
Author(s):  
Karel J. Zuzak ◽  
Sabira C. Naik ◽  
George Alexandrakis ◽  
Doyle Hawkins ◽  
Khosrow Behbehani ◽  
...  