scholarly journals Simulation, Design, and Test of a Dual-Differential D-Dot Overvoltage Sensor Based on the Field-Circuit Coupling Method

Sensors ◽  
2019 ◽  
Vol 19 (15) ◽  
pp. 3413 ◽  
Author(s):  
Pengcheng Zhao ◽  
Jingang Wang ◽  
Qian Wang ◽  
Qianbo Xiao ◽  
Ruiqiang Zhang ◽  
...  

Accurate measurement of overvoltage in power grids is of great significance to study the characteristics of overvoltage and design of insulation coordination. Based on the research of D-dot voltage sensor, we designed a Dual-Differential D-dot overvoltage sensor. In order to quantify the structural parameters of the sensor, improve the performance and measurement accuracy of the sensor. The Field-Circuit Coupling method was proposed to be used in the parameter design of D-dot overvoltage sensor. The joint simulation of space electromagnetic field model and equivalent circuit model of the Dual-Differential D-dot overvoltage sensor was established with the finite element simulation software Ansoft Maxwell and circuit simulation software Simplorer. Finally, the actual sensor was manufactured. A test platform was built to verify the steady-state and transient performance of the sensor. The results show that the Dual-Differential D-dot sensor has excellent steady-state and transient performance, the error of phase and amplitude are small, and the sensor can achieve the non-contact measurement of power transmission line. Simultaneously, the rationality of the Field-Circuit Coupling method was further verified.

2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Franz Kaiser ◽  
Vito Latora ◽  
Dirk Witthaut

AbstractIn our daily lives, we rely on the proper functioning of supply networks, from power grids to water transmission systems. A single failure in these critical infrastructures can lead to a complete collapse through a cascading failure mechanism. Counteracting strategies are thus heavily sought after. In this article, we introduce a general framework to analyse the spreading of failures in complex networks and demostrate that not only decreasing but also increasing the connectivity of the network can be an effective method to contain damages. We rigorously prove the existence of certain subgraphs, called network isolators, that can completely inhibit any failure spreading, and we show how to create such isolators in synthetic and real-world networks. The addition of selected links can thus prevent large scale outages as demonstrated for power transmission grids.


2004 ◽  
Vol 27 (2) ◽  
pp. 119-123 ◽  
Author(s):  
Haiwen Liu ◽  
Xiaowei Sun ◽  
Zhengfan Li

A new and simple parameter-extraction method for the equivalent circuit of defected ground structure (DGS) is presented. Using this method, circuit simulation, based on the DGS equivalent-circuit model, show excellent agreements with the electromagnetic (EM) simulation. Further, our method is applied effectively to design a low-pass filter (LPF) with DGS. Comparison between simulation and measurement confirm the validity of the LPF configuration and design procedure. Simple structure and high power handling capability are obtained from the proposed LPF.


Author(s):  
Wei Yao ◽  
Zhaoming Qian

In this paper, an improved load sharing control scheme is presented, which is able to improve the transient response and power sharing accuracy of parallel-connected inverters used in microgrid. It also shows how the improved droop method can be easily adapted to account for the operation of parallel-connected inverters, providing good performance under the variation and disturbance of loads, as well as achieving good steady-state objectives and transient performance. Two DSP-based single-phase Microgrid inverters are designed and implemented. Simulation and experimental results are all reported, confirming the validity of the proposed control technique.


2006 ◽  
Vol 4 (4) ◽  
pp. 516-519 ◽  
Author(s):  
D. Asprino ◽  
L. Conte ◽  
M. Pagano ◽  
G. Velotto

The paper focuses on the experimental results of a series of tests performed on a hybrid electrical source. The hybrid generator is made up of a fuel cell primary source equipped with an ultracapacitor storage device. The paper presents an examination of the steady-state and transient performance of the hybrid fuel cell-ultracapacitor source in terms of power quality. The aim is to investigate on fuel cell-ultracapacitor source’s behavior to feed pulsing loads.


2018 ◽  
Vol 8 (5) ◽  
pp. 3332-3337
Author(s):  
N. M. Khoa ◽  
D. D. Tung

The impact of thyristor controlled series capacitor (TCSC) on distance protection relays in transmission lines is analyzed in this paper. Voltage and current data are measured and collected at the relay locations to calculate the apparent impedance seen by distance protection relays in the different operating modes of the TCSC connected to the line. Short-circuit faults which occur at different locations on the power transmission line are considered in order to locate the fault for the purpose of evaluating the impact of TCSC on the distance protection relay. Matlab/Simulink simulation software is used to model the power transmission line with two sources at the two ends. Voltage source, transmission line, TCSC, voltage and current measurement, and discrete Fourier transform (DFT) blocks are integrated into the model. Simulation results show the impact of TCSC on the distance protection relay and determine the apparent impedance and fault location in the line.