General equations of the line represented by discrete parameters. I. Steady state (power transmission lines)

1991 ◽  
Vol 6 (1) ◽  
pp. 295-301 ◽  
Author(s):  
L.M. Popovic
Vestnik IGEU ◽  
2020 ◽  
pp. 14-24
Author(s):  
V.P. Golov ◽  
A.V. Kalutskov ◽  
D.N. Kormilitsyn ◽  
O.S. Sukhanova

Currently there is a need to synchronize operation of the electric power system in the remote areas and increase of existing lines transmission capacity. The construction of new power transmission lines involves high economic expenditures. Well-known papers consider the issues of application of controlled series compensation devices only for long-distance power transmission lines with voltage of 500 kV and higher to increase the transmission capacity and the level of stability. The aim of the study is to increase the stability and the limit of the transmitted power when controlled series compensation devices are installed on 220 kV lines. It is necessary to develop a criterion of aperiodic steady-state stability of an electric power system with a 220 kV-controlled power transmission line. Methods of mathematical modeling of electric power system, the theory of long-distance power transmission lines and electromechanical transients, and methods of analyzing electric power system stability were used. A.M. Lyapunov’s first approximation method was used to develop a simplified mathematical model. We applied the developed software as a simulation tool. An analysis was carried out to study the influence of series compensation devices regulation coefficients on the aperiodic steady-state stability of the electric power system and the transmission capacity of 220 kV power transmission lines. A change in the modulus of voltage drop at the power transmission and the angle characteristics under the influence of the regulation coefficients of the series compensation device was revealed. A criterion of aperiodic steady-state stability has been developed for systems of this kind with controlled series compensation. It differs from traditional ones by considering the changes in the voltage drop in the power transmission and it allows more accurate estimation of the proximity to the stability threshold. An assessment of aperiodic steady-state stability according to the formulated criterion for an electric power system with a controlled series compensation device on a 220 kV line was obtained. The values of the control coefficients of the series compensation device have been determined. No violation of the steady-state stability occurs under the given values. The results can be used to solve the issues of increasing the transmission capacity of transmission lines to improve the stability of the system.


2016 ◽  
Vol 2016 (4) ◽  
pp. 8-10 ◽  
Author(s):  
B.I. Kuznetsov ◽  
◽  
A.N. Turenko ◽  
T.B. Nikitina ◽  
A.V. Voloshko ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (6) ◽  
pp. 1561
Author(s):  
Hao Chen ◽  
Zhongnan Qian ◽  
Chengyin Liu ◽  
Jiande Wu ◽  
Wuhua Li ◽  
...  

Current measurement is a key part of the monitoring system for power transmission lines. Compared with the conventional current sensor, the distributed, self-powered and contactless current sensor has great advantages of safety and reliability. By integrating the current sensing function and the energy harvesting function of current transformer (CT), a time-multiplexed self-powered wireless sensor that can measure the power transmission line current is presented in this paper. Two operating modes of CT, including current sensing mode and energy harvesting mode, are analyzed in detail. Through the design of mode-switching circuit, harvesting circuit and measurement circuit are isolated using only one CT secondary coil, which eliminates the interference between energy harvesting and current measurement. Thus, the accurate measurement in the current sensing mode and the maximum energy collection in the energy harvesting mode are both realized, all of which simplify the online power transmission line monitoring. The designed time-multiplexed working mode allows the sensor to work at a lower transmission line current, at the expense of a lower working frequency. Finally, the proposed sensor is verified by experiments.


IEEE Access ◽  
2021 ◽  
pp. 1-1
Author(s):  
Vedanta Pradhan ◽  
O. D. Naidu ◽  
Sinisa Zubic ◽  
Patrick Cost

Sign in / Sign up

Export Citation Format

Share Document