scholarly journals Experimental Study of Oriented Strand Board Ignition by Radiant Heat Fluxes

Polymers ◽  
2021 ◽  
Vol 13 (5) ◽  
pp. 709
Author(s):  
Ivana Tureková ◽  
Iveta Marková ◽  
Martina Ivanovičová ◽  
Jozef Harangózo

Wood and composite panel materials represent a substantial part of the fuel in many building fires. The ability of materials to ignite when heated at elevated temperatures depends on many factors, such as the thermal properties of materials, the ignition temperature, critical heat flux and the environment. Oriented strand board (OSB) without any surface treatment in thicknesses of 12, 15 and 18 mm were used as experimental samples. The samples were gradually exposed to a heat flux of 43 to 50 kW.m−2, with an increase of 1 kW.m−2. At heat fluxes of 49 kW.m−2 and 50 kW.m−2, the ignition times are similar in all OSB thicknesses, in contrast to the ignition times at lower heat fluxes. The influence of the selected factors (thickness and distance from the heat source) was analysed based on the experimentally obtained data of ignition time and weight loss. The experimentally determined value of the heat flux density was 43 kW.m−2, which represented the critical heat flux. The results show a statistically significant effect of OSB thickness on ignition time.

Author(s):  
A. Lamorlette

This study aims at characterizing ignition of solid targets exposed to spreading fire fronts. In order to model radiant heat fluxes on targets in a realistic way, polynomial heat fluxes are chosen. Analytical solutions for the solid surface temperature evolution regarding different time-varying heat fluxes are discussed for high thermal inertia solids using a mathematical formalism, which allows for the methodology to be extended to the case of low thermal inertia. This formulation also allows calculation of ignition times for more realistic time-dependent fluxes than previous studies on the topic, providing a more general solution to the problem of solid material ignition. Polynomial coefficients are then obtained fitting heat flux coming from absorbing–emitting flames. A characterization of solid material ignition times regarding fire front rate of spread (ROS) is finally performed, showing the need to accurately model heat flux variations in ignition time calculations.


2021 ◽  
pp. 073490412110366
Author(s):  
Junhui Gong ◽  
Hongen Zhou ◽  
Hong Zhu ◽  
Conor G McCoy ◽  
Stanislav I Stoliarov

Oriented strand board is a widely used construction material responsible for a substantial portion of the fire load of many buildings. To accurately model oriented strand board fire response, kinetics and thermodynamics of its thermal decomposition and combustion were carefully characterized using milligram-scale testing in part I of this study. In the current work, Controlled Atmosphere Pyrolysis Apparatus II tests were performed on representative gram-sized oriented strand board samples at a range of radiant heat fluxes. An automated inverse analysis of the sample temperature data obtained in these tests was employed to determine the thermal conductivities of the undecomposed oriented strand board and condensed-phase products of its decomposition. A complete pyrolysis model was formulated for this material and used to predict the mass loss rates measured in the Controlled Atmosphere Pyrolysis Apparatus II experiments. These mass loss rate profiles were predicted well with the exception of the second mass loss rate peak observed at 65 kW m−2 of radiant heat flux, which was underpredicted. To further validate the model, cone calorimeter tests were performed on oriented strand board at 25 and 50 kW m−2 of radiant heat flux. The results of these tests, including both mass loss rate and heat release rate profiles, were predicted reasonably well by the model.


2011 ◽  
Vol 134 (1) ◽  
Author(s):  
Tailian Chen ◽  
Suresh V. Garimella

The cooling capacity of two-phase transport in microchannels is limited by the occurrence of critical heat flux (CHF). Due to the nature of the phenomenon, it is challenging to obtain reliable CHF data without causing damage to the device under test. In this work, the critical heat fluxes for flow boiling of FC-77 in a silicon thermal test die containing 60 parallel microchannels were measured at five total flow rates through the microchannels in the range of 20–80 ml/min. CHF is caused by dryout at the wall near the exit of the microchannels, which in turn is attributed to the flow reversal upstream of the microchannels. The bubbles pushed back into the inlet plenum agglomerate; the resulting flow blockage is a likely cause for the occurrence of CHF which is marked by an abrupt increase in wall temperature near the exit and an abrupt decrease in pressure drop across the microchannels. A database of 49 data points obtained from five experiments in four independent studies with water, R-113, and FC-77 as coolants was compiled and analyzed. It is found that the CHF has a strong dependence on the coolant, the flow rate, and the area upon which the heat flux definition is based. However, at a given flow rate, the critical heat input (total heat transfer rate to the coolant when CHF occurs) depends only on the coolant and has minimal dependence on the details of the microchannel heat sink (channel size, number of channels, substrate material, and base area). The critical heat input for flow boiling in multiple parallel microchannels follows a well-defined trend with the product of mass flow rate and latent heat of vaporization. A power-law correlation is proposed which offers a simple, yet accurate method for predicting the CHF. The thermodynamic exit quality at CHF is also analyzed and discussed to provide insights into the CHF phenomenon in a heat sink containing multiple parallel microchannels.


Author(s):  
A. E. Bergles

During the past 20 years, there has been intense worldwide interest in microchannel heat exchangers, particularly for cooling of microelectronic components. Saturated boiling of the coolant is usually indicated in order to accommodate high heat fluxes and to have uniformity of temperature. However, boiling is accompanied by several instabilities, the most severe of which can sharply limit the maximum, or critical, heat flux. These stability phenomena are reviewed, and recent studies will be discussed. Elevation of the critical heat flux will be discussed within the context of heat transfer enhancement. Means to improve the stability of boiling and the enhancement of boiling heat transfer, in general, are discussed.


1991 ◽  
Vol 113 (1) ◽  
pp. 91-99
Author(s):  
B. Ross ◽  
P. G. Parikh

A massive chain of property damaging explosions involving an ammunition train occurred at the railroad yard, Roseville, California. The train had pulled into the yard after a night trip of some 100 miles across Donner Summit and down the extended Norden-Roseville grade. Physical evidence confirmed that first explosions were centered at a DODX type boxcar loaded with 250 lb. bombs. Further, bomb cook-off detonation tests established that the triggering bomb blast was not a result of shock loads but rather derived from an engulfing fire initiated in the boxcar wood plank floor under influence of extended heavy braking action on the mountain grade. It was also suspected that high friction composition brake shoes were fitted on the car as replacements for cast iron shoes but the brake mechanical linkage lever ratios had not been modified as required. Results of a comprehensive research program are presented within context of the explosion event, and include analytical computer simulation of train descent profiles on mountain grades through full scale dynamometer tests with actual rail wheels and ultimately more scientific scaled wood floor ignition experiments in the laboratory. The thermal response of a simulated DODX boxcar wood floor was studied through experiments, full scale at a rail wheel dynamometer test facility, and in the laboratory. Certain input data for the wood floor ignition test program were measured on an actual boxcar joined with a freight train consist in transit down the Norden-Roseville grade. Two series of scaled wood ignition experiments were conducted on simulated DODX boxcar floors. Objectives of these tests were to determine: Influence of a cooling air stream on the ignition behavior of radiantly heated wood surfaces, and effectiveness of DODX (stand-off) and AAR (flush) type spark shields in preventing ignition of wood surfaces under radiant heating. It was found that for radiant heat flux levels representative of high friction composition shoes under severe train braking conditions, low speed airflow (wind) exerts a dramatic influence on the wood ignition time. For example, average ignition time for a simulated boxcar floor at a heat flux level of 0.4 cal/cm2sec was determined to be 15.6 min. with a 5 mph wind as compared to 3.6 min. with no wind. In the spark shield effectiveness tests, conducted at heat flux levels representative of cast iron shoes under severe braking conditions, the DODX (stand-off) type spark shield failed to prevent spontaneous flaming ignition of a wood surface directly above it. Under identical conditions, no flaming ignition was encountered with the AAR (flush) type spark shield.


1964 ◽  
Vol 86 (1) ◽  
pp. 12-22 ◽  
Author(s):  
F. E. Tippets

High-speed motion pictures (4300 pictures/sec) of boiling water flow patterns in conditions of forced flow at 1000 psia pressure in a vertical heated rectangular channel were taken over the range of mass velocities from 50 to 400 lb/sec-ft2, fluid states from bulk subcooled liquid flow to bulk boiling flow at 0.66 steam quality, and heat fluxes up to and including the critical heat flux level. Eighty critical heat flux determinations were made in the course of the experiment at 1000 psia in conditions of bulk boiling. The motion pictures provide photographic evidence of the general arrangement of the flow in conditions of bulk boiling at high pressure with heat fluxes near and including the critical heat flux level.


2016 ◽  
Vol 11 (3) ◽  
pp. 155892501601100
Author(s):  
Thomas Godfrey ◽  
Margaret Auerbach ◽  
Gary Proulx ◽  
Pearl Yip ◽  
Michael Grady

American soldiers and marines involved in the recent conflicts in Iraq and Afghanistan have suffered increased incidence of burn injury, often as a direct result of exposure to improvised explosive devices. In this work, a one dimensional numerical pyrolysis model for transient heat conduction, incorporating material transformations described by chemical kinetics, is used to investigate the response of the standard 230 g/m2 Army Combat Uniform (ACU) fabric to high radiant heat fluxes in short duration thermal protection tests and long duration cone calorimeter tests. Thermal protection tests are performed using a Thermal Barrier Test Apparatus–an automated device, incorporating a closed-loop controlled IR radiant heat source, automated water cooled shutter, a fabric sample holder, an adjustable stage with a water cooled Schmidt-Boelter heat flux gauge and a PC based data acquisition system. Cone calorimeter tests are performed on fabric specimens at an exposure heat flux of 25 kW/m2. In thermal protection tests involving exposures of 90 kW/m2 for five seconds and 77 kW/m2 for four seconds, modeling indicated that desorption and evaporation of moisture content has an important effect, but melting of the nylon component and material decomposition had insignificant effects on the heat flux transmitted through the fabric back face. Modeling results for cone testing exhibited good agreement for time to ignition and duration of flaming combustion.


1990 ◽  
Vol 112 (3) ◽  
pp. 241-248 ◽  
Author(s):  
Issam Mudawar ◽  
Douglas E. Maddox

Several surface augmentation techniques were examined in an investigation of enhancement of critical heat flux (CHF) from a simulated electronic chip to a fluorocarbon (FC-72) liquid in a vertical channel. A parametric comparison of boiling performances is presented for a smooth surface and for surfaces with low-profile microgrooves, low-profile microstuds, and high-profile pin fins. Critical heat fluxes as high as 361 W/cm2 were achieved using a combination of moderate flow velocity, high subcooling and surface enhancement. A semiempirical model constructed previously for CHF from a smooth discrete heat source to saturated or subcooled liquid flow, was found successful in correlating CHF data for the three enhanced surfaces.


2006 ◽  
Vol 129 (7) ◽  
pp. 844-851 ◽  
Author(s):  
Ali Koşar ◽  
Yoav Peles

Critical heat flux (CHF) of R-123 in a silicon-based microchannel heat sink was investigated at exit pressures ranging from 227kPato520kPa. Critical heat flux data were obtained over effective heat fluxes ranging from 53W∕cm2to196W∕cm2 and mass fluxes from 291kg∕m2sto1118kg∕m2s. Flow images and high exit qualities suggest that dryout is the leading CHF mechanism. The effect of mass velocity, exit quality, and system pressure were also examined, and a new correlation is presented to represent the effect of these parameters.


1981 ◽  
Vol 103 (4) ◽  
pp. 660-666 ◽  
Author(s):  
M. K. Jensen ◽  
A. E. Bergles

A study of boiling R-113 in electrically heated coils of various diameters is reported. Subcooled critical heat flux (CHF) is lower with coils than with straight tubes. The difference increases as mass velocity and ratio of tube diameter to coil diameter (d/D) increases. On the contrary, quality CHF is enhanced and increases with d/D; CHF initially increases with increasing mass velocity, but decreases after a maximum is reached. Operational problems, in particular upstream dryouts, can occur if a coiled tube is operated with low to moderate subcooling near the inlet and with moderately high heat fluxes.


Sign in / Sign up

Export Citation Format

Share Document