Critical Heat Fluxes and Flow Patterns in High-Pressure Boiling Water Flows

1964 ◽  
Vol 86 (1) ◽  
pp. 12-22 ◽  
Author(s):  
F. E. Tippets

High-speed motion pictures (4300 pictures/sec) of boiling water flow patterns in conditions of forced flow at 1000 psia pressure in a vertical heated rectangular channel were taken over the range of mass velocities from 50 to 400 lb/sec-ft2, fluid states from bulk subcooled liquid flow to bulk boiling flow at 0.66 steam quality, and heat fluxes up to and including the critical heat flux level. Eighty critical heat flux determinations were made in the course of the experiment at 1000 psia in conditions of bulk boiling. The motion pictures provide photographic evidence of the general arrangement of the flow in conditions of bulk boiling at high pressure with heat fluxes near and including the critical heat flux level.

1964 ◽  
Vol 86 (1) ◽  
pp. 23-33 ◽  
Author(s):  
F. E. Tippets

Based on the two-phase flow patterns shown in high-speed motion pictures of the process, a general working equation is derived which relates the critical heat flux for high-pressure bulk boiling water in forced convection to the significant local flow parameters and fluid properties. The equation is applied to a representative selection of several hundred data points from the major available sources for the purpose of investigating trends in the data and to test the validity of the equation.


1999 ◽  
Author(s):  
Yasuo Koizumi ◽  
Hiroyasu Ohtake ◽  
Manabu Mochizuki

Abstract The effect of solid particle introduction on subcooled-forced flow boiling heat transfer and a critical heat flux was examined experimentally. In the experiment, glass beads of 0.6 mm diameter were mixed in subcooled water. Experiments were conducted in a range of the subcooling of 40 K, a velocity of 0.17–6.7 m/s, a volumetric particle ratio of 0–17%. When particles were introduced, the growth of a superheated liquid layer near a heat trasnsfer surface seemed to be suppressed and the onset of nucleate boiling was delayed. The particles promoted the condensation of bubbles on the heat transfer surface, which shifted the initiation of a net vapor generation to a high heat flux region. Boiling heat trasnfer was augmented by the particle introduction. The suppression of the growth of the superheated liquid layer and the promotion of bubble condensation and dissipation by the particles seemed to contribute that heat transfer augmentation. The wall superheat at the critical heat flux was elevated by the particle introduction and the critical heat flux itself was also enhanced. However, the degree of the critical heat flux improvement was not drastic.


2011 ◽  
Vol 134 (1) ◽  
Author(s):  
Tailian Chen ◽  
Suresh V. Garimella

The cooling capacity of two-phase transport in microchannels is limited by the occurrence of critical heat flux (CHF). Due to the nature of the phenomenon, it is challenging to obtain reliable CHF data without causing damage to the device under test. In this work, the critical heat fluxes for flow boiling of FC-77 in a silicon thermal test die containing 60 parallel microchannels were measured at five total flow rates through the microchannels in the range of 20–80 ml/min. CHF is caused by dryout at the wall near the exit of the microchannels, which in turn is attributed to the flow reversal upstream of the microchannels. The bubbles pushed back into the inlet plenum agglomerate; the resulting flow blockage is a likely cause for the occurrence of CHF which is marked by an abrupt increase in wall temperature near the exit and an abrupt decrease in pressure drop across the microchannels. A database of 49 data points obtained from five experiments in four independent studies with water, R-113, and FC-77 as coolants was compiled and analyzed. It is found that the CHF has a strong dependence on the coolant, the flow rate, and the area upon which the heat flux definition is based. However, at a given flow rate, the critical heat input (total heat transfer rate to the coolant when CHF occurs) depends only on the coolant and has minimal dependence on the details of the microchannel heat sink (channel size, number of channels, substrate material, and base area). The critical heat input for flow boiling in multiple parallel microchannels follows a well-defined trend with the product of mass flow rate and latent heat of vaporization. A power-law correlation is proposed which offers a simple, yet accurate method for predicting the CHF. The thermodynamic exit quality at CHF is also analyzed and discussed to provide insights into the CHF phenomenon in a heat sink containing multiple parallel microchannels.


Sign in / Sign up

Export Citation Format

Share Document