scholarly journals Bending Fatigue Behavior of 316L Stainless Steel up to Very High Cycle Fatigue Regime

Materials ◽  
2020 ◽  
Vol 13 (21) ◽  
pp. 4820
Author(s):  
Yongtao Hu ◽  
Yao Chen ◽  
Chao He ◽  
Yongjie Liu ◽  
Qingyuan Wang ◽  
...  

Effect of microstructure on the crack initiation and early propagation mechanism in the very high cycle fatigue (VHCF) regime was studied in 316L stainless steel (316L SS) by atomic force microscope (AFM) and electron back scattered diffraction (EBSD). The results show that small fatigue cracks initiate from the slip band near the grain boundaries (GBs) or the twin boundaries (TBs). Early crack propagation along or cross the slip band is strongly influenced by the local microstructure such as grain size, orientation, and boundary. Besides, the gathered slip bands (SBs) are presented side by side with the damage grains of the run-out specimen. Finally, it is found that dislocations can either pass through the TBs, or be arrested at the TBs.

Materials ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3293
Author(s):  
Boris Voloskov ◽  
Stanislav Evlashin ◽  
Sarkis Dagesyan ◽  
Sergey Abaimov ◽  
Iskander Akhatov ◽  
...  

The present paper is focused on an experimental study of the damage-to-failure mechanism of additively manufactured 316L stainless steel specimens subjected to very high cycle fatigue (VHCF) loading. Ultrasonic axial tension-compression tests were carried out on specimens for up to 109 cycles, and fracture surface analysis was performed. A fine granular area (FGA) surrounding internal defects was observed and formed a “fish-eye” fracture type. Nonmetallic inclusions and the lack of fusion within the fracture surfaces that were observed with SEM were assumed to be sources of damage initiation and growth of the FGAs. The characteristic diameter of the FGAs was ≈500 μm on the fracture surface and were induced by nonmetallic inclusions; this characteristic diameter was the same as that for the fracture surface induced by a lack of fusion. Fracture surfaces corresponding to the high cycle fatigue (HCF) regime were discussed as well to emphasize damage features related to the VHCF regime.


2019 ◽  
Vol 9 (9) ◽  
pp. 1120-1126
Author(s):  
Baohua Nie ◽  
Zihua Zhao ◽  
Dongchu Chen ◽  
Fangjun Liu ◽  
Jishi Zhao ◽  
...  

Very high cycle fatigue (VHCF) behavior of the diffusion bonded joints between 3Cr13 and 2Cr13 were investigated. Results showed that the diffusion bonded joints obtained a comparable fatigue property of 2Cr13, and the S–N curves exhibited a decreasing shape characteristic. However, fatigue life was dramatically decreased by occasional non-diffusion defects. Fatigue cracks in diffusion bonded joints occurred at specimen's surface in high cycle regimes, whereas VHCF cracks were originated from inclusions on the side of 2Cr13 based materials, in which the fine granular area (FGA) characteristics were observed around the internal inclusion. Furthermore, fatigue strength of the diffusion joints was interpreted based on the Murakami model. The crack propagation life estimated by Paris-Hertzberg-McClintock model mainly contributed for the fatigue life of the specimens with occasional non-fusion defects, in which non-fusion defects acted as pre-cracks.


Metals ◽  
2018 ◽  
Vol 8 (12) ◽  
pp. 1023 ◽  
Author(s):  
Byung-Hoon Lee ◽  
Sung-Woo Park ◽  
Soong-Keun Hyun ◽  
In-Sik Cho ◽  
Kyung-Taek Kim

The effect of heat treatment condition on non-Cu AA7021 alloy was investigated with respect to mechanical properties and very high cycle fatigue behavior. With a focus on the influence of heat treatment, AA7021 alloy was solution heat-treated at 470 °C for 4 h and aged at 124 °C. Comparing the results of solution-treated and peak-aged AA7021 alloy shows a significant increase in Vickers hardness and tensile strength. The hardness of AA7021 alloy was increased by 65% after aging treatment, and both tensile strength and yield strength were increased by 50~80 MPa in each case. In particular, this paper investigated the very high cycle fatigue behavior of AA7021 alloy with the ultrasonic fatigue testing method using a resonance frequency of 20 kHz. The fatigue results showed that the stress amplitude of peak-aged AA7021 alloy was about 50 MPa higher than the solution-treated alloy at the same fatigue cycles. Furthermore, it was confirmed that the size of the crack initiation site was larger after peak aging than after solution treatment.


2015 ◽  
Vol 825-826 ◽  
pp. 150-157 ◽  
Author(s):  
Alexandra Müller ◽  
Anja Weidner ◽  
Horst Biermann

During technical operation, high performance materials are partially exposed to high frequency cyclic loading conditions. Furthermore, the small strains in the very high cycle fatigue (VHCF)-regime lead to accumulative damage which causes crack initiation related to an appropriate local deformation leading to final fatal fracture. At the same time, quite high requirements with regard to high number of cycles without any damage are demanded for many applications. Fields of application of these light-weight, but expensive materials, are e.g. in the automobile industry (e.g. engine blocks, cylinder heads, brakes).The fatigue behavior of Al-matrix composites (Al-MMCs) reinforced by alumina particles (15 vol.% Al2O3) or short fibers (20 vol.% Saffil), respectively, was already intensively studied in the LCF and HCF range. The present study is focusing on investigations in the very high cycle fatigue regime at stress amplitudes up to 140 MPa to reach fatigue life of about 1010 cycles. All experiments were carried out using an ultrasonic fatigue testing device under symmetric loading conditions (R=-1). Fatigue tests were accompanied by in situ thermography measurements to record the temperature of the whole specimen and to find “hot spots” indicating changes in microstructure and therefore the initiation or growth of cracks. Moreover, the resonant frequency as well as the damage parameter were evaluated to determine the beginning of damage. For a better understanding of the damage mechanism (matrix decohesion, matrix failure or failure of reinforcement) all fractured surfaces were investigated by scanning electron microscopy. The combination of these methods contributes to a better understanding of the underlying mechanism of damage in aluminum-matrix-composites.


2016 ◽  
Vol 258 ◽  
pp. 255-258
Author(s):  
Ulrich Krupp ◽  
Marcus Söker ◽  
Tina Waurischk ◽  
Alexander Giertler ◽  
Benjamin Dönges ◽  
...  

As being used for structural applications, where a high corrosion resistance is required, the fatigue behavior of duplex stainless steels (DSS) is governed by the partition of cyclic plasticity to the two phases, ferrite and austenite, respectively. Under very high cycle fatigue (VHCF) loading conditions, the heterogeneous distribution of crystallographic misorientations between neighboring grains and phases yields to a pronounced scatter in fatigue life, ranging from 1 million to 1 billion cycles for nearly the same stress amplitude. In addition, the relevant damage mechanisms depend strongly on the atmosphere. Stress corrosion cracking in NaCl-containing atmosphere causes a pronounced decrease in the VHCF life. By means of ultrasonic fatigue testing at 20kHz in combination with high resolution scanning electron microscopy, electron back-scattered diffraction (EBSD), focused ion beam milling (FIB) and synchrotron tomography, the microstructure heterogeneities were quantified and correlated with local fatigue damage. It has been shown that the fatigue process is rather complex, involving redistribution of residual stresses and three-dimensional barrier effects of the various interfaces. The application of a 2D/3D finite element model allows a qualitative prediction of the fatigue-damage process in DSS that is controlled by stochastic local microstructure arrangements.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Xu Jia ◽  
Yang Ou Xiang ◽  
Hu Yuan Pei ◽  
Song Wei

PurposeThe investigations could guide the structural design and fatigue life prediction of air-conditioning compressor valve plates.Design/methodology/approachThe High-Cycle Fatigue (HCF) and Very-High-Cycle Fatigue (VHCF) behaviors of stainless steel used for air-conditioning compressor valve plates were investigated. Monotonic and cyclic loading conditions were designed to explore the fatigue responses according to the load characteristics of the structure.FindingsThe crack initiation can be observed as the arc-shaped cracks at both sides of specimens and Y-shaped crack bifurcation in the specimens. Moreover, the middle section and the cracks at both ends are not connected to the surface of the specimen. The stress-life results of the materials under two directions (vertical and horizontal) were provided to examine the difference in fatigue strength.Originality/valueMonotonic and cyclic loading conditions were designed to explore the fatigue responses according to the load characteristics of the structure. Based on the experimental data, the results indicate that specimens under cyclic loading conditions could demonstrate better mechanical performance than static loadings.


Sign in / Sign up

Export Citation Format

Share Document