scholarly journals Experimental and Numerical Study on Shear Resistance of Notched Perfobond Shear Connector

Materials ◽  
2019 ◽  
Vol 12 (3) ◽  
pp. 341 ◽  
Author(s):  
Shuangjie Zheng ◽  
Yuqing Liu ◽  
Yangqing Liu ◽  
Chen Zhao

In steel and concrete composite bridges, it is difficult to perforate the reinforcing bars through the circular holes of conventional perfobond shear connectors with multi-ribs. To ease the installation of perforating rebars, an alternative notched perfobond shear connector was proposed by cutting out the edge of the circular hole. This paper presents the push-out test results of six specimens which were fabricated and loaded to failure. The main purpose was to compare the failure mode, shear capacity and slip behavior of perfobond shear connectors using circular holes and notched holes. Furthermore, 43 nonlinear finite element simulations were performed to further study the effects of several variables, including the hole diameter, the hole distance, the hole number, the cut width, the perfobond thickness, the concrete strength, the rebar diameter, the rebar strength, and the steel strength. The parametric results were generated to evaluate the shear capacity equations for perfobond shear connectors. Finally, an analytical model was developed to estimate the shear capacity of notched perfobond shear connectors.

2019 ◽  
Vol 9 (4) ◽  
pp. 764 ◽  
Author(s):  
Shuangjie Zheng ◽  
Yuqing Liu ◽  
Yangqing Liu ◽  
Chen Zhao

To ease the installation of perforating rebars through multi-holes, an alternative notched perfobond shear connector was proposed by cutting out the hole edge. This paper presents the test results of six pull-out specimens with conventional and notched perfobond shear connectors. The objective was to compare the failure modes and pull-out behaviors of perfobond shear connectors using circular holes and notched holes. Furthermore, the explicit finite element method was introduced and validated to generate parametric results for pull-out tests of notched perfobond shear connectors. A total of 33 parametric simulations were performed to further study the influences of several variables, including the hole diameter, the cut width, the perfobond thickness, the concrete strength, the diameter and strength of the rebar, and the strength of the structural steel. The experimental and numerical results were used to evaluate the previous equations for perfobond shear connectors. Finally, an alternative equation was proposed to estimate the pull-out resistance of notched perfobond shear connectors.


Materials ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 2958 ◽  
Author(s):  
Jun Chen ◽  
Wei Wang ◽  
Fa-Xing Ding ◽  
Ping Xiang ◽  
Yu-Jie Yu ◽  
...  

The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.


2006 ◽  
Vol 326-328 ◽  
pp. 1811-1816 ◽  
Author(s):  
Young Ho Kim ◽  
Jae Ho Jung ◽  
Soon Jong Yoon ◽  
Won Sup Jang

In the construction of composite bridge structures, various types of shear connectors are usually used to provide an efficient load transfer and the composite action of two or more different materials. In the previous work conducted by authors, a new type of the shear connector was introduced, which is the perforated shear connector with flange heads (T-shaped perforated shear connector), and the structural behavior of the shear connector was discussed based on the results of push-out tests. For the practical design of new shear connector, it is necessary to develop the equation for the prediction of the load carrying capacity of the shear connector. In this study, the existing design equations for the Perfobond shear connector were briefly analyzed and the equation for the prediction of the shear capacity of T-shaped perforated shear connector was suggested empirically. By comparing the results obtained by the suggested equation, the existing equations for the Perfobond shear connector, and the experiment, the applicability and effectiveness of the suggested equation was estimated.


2012 ◽  
Vol 512-515 ◽  
pp. 1991-1994
Author(s):  
Yang Wang ◽  
Tian Li

A new stud—double-nut stud was present. The goals of the study were two fold, firstly to compare with traditional stud and secondly to search the affect factors of capacity, get calculation equations .We present an analysis of double-nut stud, include different concrete strength and different stud size. This study showed double-nut stud is better than traditional stud, for it has higher shearing stiffness and bearing capacity, makes steel beam and the concrete slab to work together. These results suggest that all equations of stud are not applicable computation double -nut stud, it should make 1.35-1.5 adjustment coefficient.


1992 ◽  
Vol 19 (1) ◽  
pp. 1-10 ◽  
Author(s):  
M. R. Veldanda ◽  
M. U. Hosain

This paper summarizes the results of tests performed on 48 push-out specimens to investigate the feasibility of using perfobond rib type shear connectors in composite beams with ribbed metal decks placed parallel to the steel beams. The perfobond rib shear connector is a flat steel plate containing a number of holes. The results indicate that perfobond rib connectors can be effectively used in composite beams with ribbed metal decks placed parallel to the steel beams. An appreciable improvement in performance was observed in test specimens when additional reinforcing bars were passed through the perfobond rib holes. Shank shear was the principal mode of failure in specimens with headed studs. In specimens with perfobond rib, failure was triggered by the longitudinal splitting of the concrete slab, followed by the crushing of concrete in front of the perfobond rib. Key words: composite beam, shear connector, perfobond rib, headed stud, push-out test, metal deck.


2020 ◽  
Vol 198 ◽  
pp. 01027
Author(s):  
Zhishun Pan

Bolted shear connectors are an important component to ensure that steel-concrete composite structures can work together. High-strength bolt shear connectors can replace traditional stud connectors because of their disassembly, good mechanical performance and fatigue resistance. It applied to steel-concrete composite structure. In order to study the influencing factors of the bearing capacity of high-strength bolted shear connectors, this paper uses ABAQUS finite element simulation software as a research tool to establish a reasonable finite element model to study the influence of bolt strength, bolt diameter and concrete strength on bolted shear connectors. Studies have shown that increasing the diameter, strength, and concrete strength of bolted connections can effectively increase the bolt’s shear capacity.


2021 ◽  
Vol 8 ◽  
Author(s):  
Wei Wang ◽  
Xie-dong Zhang ◽  
Xi-long Zhou ◽  
Lin Wu ◽  
Hao-jie Zhu

Multi-bolt shear connectors (MBSCs), arranging bolts as a group in several rows, can be applied in prefabricated steel–concrete composite beams or bridges (SCCBs) to reduce the construction time and meet the requirements of sustainable development. The mechanical behavior of bolt shear connectors has been broadly investigated in recent years, but they were mainly focused on the normal arrangement. The shear performance of MBSCs is not consistent with that of the same number of single bolts. In this study, a three-dimensional (3D) finite element model (FEM) was developed to investigate the multiple bolts effect and its mechanical performance. Material non-linearities and the interactions among all components were included in the FEM. The accuracy and reliability of the proposed FEM were initially verified against the available push-out test results. The validated FEM further studied the load–slip relationship, shear capacity, and shear stiffness of the MBSCs. A parametric study was carried out to determine the effect of the bolt spacing, bolt row numbers, the concrete strength, and the bolt diameter on the shear performance of MBSCs. Based on the extensive parametric analyses, design recommendations considering the multiple bolts effect for predicting the shear resistance per bolt in multi-bolt connectors were proposed and verified.


Author(s):  
Jie Yang ◽  
Dennis Lam ◽  
Xianghe Dai ◽  
Therese Sheehan

This paper presents an experimental study on demountable shear connectors in profiled composite slabs. Overall, three groups of push-off tests were conducted to assess the shear capacity, stiffness and ductility of the shear connectors. In all the specimens, a pair of shear studs were used per trough and were bolted to each side of the flange of a loading beam. Different concrete strength, embedment height of the shear studs and reinforcement cage were considered. Particularly, a joint was made between the pair studs in two groups of specimens when casting and formed two completely separate slabs per half specimen, to evaluate the load transfer between the pair studs. The experimental results showed that the shear capacity and behavior of the demountable connectors in separate slabs and continuous slab were both similar to the welded connectors and could fulfill the 6mm minimum ductility requirement stated in Eurocode 4 if proper embedment height of connector was used. The shear capacities of the tested specimens were compared against the calculated results obtained from the equations used for welded shear connectors in Eurocode 4 and bolted connections in Eurocode 3. Generally, the Eurocodes prediction underestimated the shear capacities of the push-off specimens.


2021 ◽  
Vol 11 (19) ◽  
pp. 9088
Author(s):  
Xuewei Wang ◽  
Qiuxia He ◽  
Zhiwen An ◽  
Guojun Liu ◽  
Xingke Wen ◽  
...  

A series of full-scale pushed out tests were performed on the Perfobond rib shear connector. The tests were designed to examine the performance of the Perfobond rib shear connector under different rib hole sizes and shapes, reinforcing bar sizes, rib thicknesses, as well as the presence of lateral forces. It has been revealed from the test results that the rib hole size and reinforcement diameter may not act independently, and the influence of one’s size is actually dependent on the size of the other one. The lateral forces also affect the performance of the shear connector; for example, the capacity of the shear connector would be larger under compression than under tension. The existence of transverse pretension stress accelerated the cracking of concrete, leading to the strength and stiffness of concrete, perforated plate, and reinforcing rebars unable to fully exert their effect. In addition, the constraint effect of transverse stress improved the strength and stiffness of concrete and delayed the concrete cracking, bringing the strength and stiffness of concrete, perforated plate, and reinforcing rebars into full play, and resulting in a significant improvement in the shear capacity of Perfobond rib shear connectors.


Sign in / Sign up

Export Citation Format

Share Document