scholarly journals Behavior of an Advanced Bolted Shear Connector in Prefabricated Steel-Concrete Composite Beams

Materials ◽  
2019 ◽  
Vol 12 (18) ◽  
pp. 2958 ◽  
Author(s):  
Jun Chen ◽  
Wei Wang ◽  
Fa-Xing Ding ◽  
Ping Xiang ◽  
Yu-Jie Yu ◽  
...  

The high-strength bolt shear connector in prefabricated concrete slab has advantages in applications as it reduces time during the construction of steel-concrete composite building structures and bridges. In this research, an innovative and advanced bolt shear connector in steel-concrete composite structures is proposed. To investigate the fundamental mechanical behavior and the damage form, 22 static push-off tests were conducted with consideration of different bolt dimensions, the reserved hole constraint condition, and the dimension of slab holes. A finite element (FE) model was established and verified by using test results, and then the model was utilized to investigate the influence of concrete strength, bolt dimension, yield strength, bolt pretension, as well as length-to-diameter ratio of high strength bolts on the performances of shear connectors. On the basis of FE simulation and test results, new design formulas for the calculation of shear resistance behavior were proposed, and comparisons were made with current standards, including AISC, EN 1994-1-1, GB 50017-2017, and relevant references, to check the calculation efficiency. It is confirmed that the proposed equation is in better agreement with the experimental results.

2019 ◽  
Vol 9 (4) ◽  
pp. 764 ◽  
Author(s):  
Shuangjie Zheng ◽  
Yuqing Liu ◽  
Yangqing Liu ◽  
Chen Zhao

To ease the installation of perforating rebars through multi-holes, an alternative notched perfobond shear connector was proposed by cutting out the hole edge. This paper presents the test results of six pull-out specimens with conventional and notched perfobond shear connectors. The objective was to compare the failure modes and pull-out behaviors of perfobond shear connectors using circular holes and notched holes. Furthermore, the explicit finite element method was introduced and validated to generate parametric results for pull-out tests of notched perfobond shear connectors. A total of 33 parametric simulations were performed to further study the influences of several variables, including the hole diameter, the cut width, the perfobond thickness, the concrete strength, the diameter and strength of the rebar, and the strength of the structural steel. The experimental and numerical results were used to evaluate the previous equations for perfobond shear connectors. Finally, an alternative equation was proposed to estimate the pull-out resistance of notched perfobond shear connectors.


2018 ◽  
Vol 7 (3.10) ◽  
pp. 54
Author(s):  
T Subramani ◽  
A Periasamy

Composite plays a vital role in replacing the existing mild steel in reinforcement and exterior truss structure. This study proposed to design shear connector for joining concrete slab and steel section. Shear connectors has analyzed and predict the best connector for a particular composite beam with respect to static load and the amount of steel in the connector as a common aspect. The use of composite structures is increasingly present in civil construction works nowadays. Composite beams, especially, are structures which include substances, a metal phase placed in particular inside the tension region and a concrete phase, positioned in the compression go sectional location, both are related with the aid of steel gadgets called shear connectors. The main features of this connector are to permit the weight for the joint the beam-column, to restriction longitudinal slipping and uplifting on the factors interface the shear forces. Our project paper presents 3D numerical models of steel-concrete composite beams to simulate their structural behaviour, with emphasis on the beam column interface using Simulations software ANSYS 18.1 based on the Finite Element Method. Mostly these type of structures are widely used in the dynamic loading structures like bridges and high rise buildings.  


2020 ◽  
Vol 198 ◽  
pp. 01027
Author(s):  
Zhishun Pan

Bolted shear connectors are an important component to ensure that steel-concrete composite structures can work together. High-strength bolt shear connectors can replace traditional stud connectors because of their disassembly, good mechanical performance and fatigue resistance. It applied to steel-concrete composite structure. In order to study the influencing factors of the bearing capacity of high-strength bolted shear connectors, this paper uses ABAQUS finite element simulation software as a research tool to establish a reasonable finite element model to study the influence of bolt strength, bolt diameter and concrete strength on bolted shear connectors. Studies have shown that increasing the diameter, strength, and concrete strength of bolted connections can effectively increase the bolt’s shear capacity.


Materials ◽  
2018 ◽  
Vol 12 (1) ◽  
pp. 29 ◽  
Author(s):  
Shuangjie Zheng ◽  
Chen Zhao ◽  
Yangqing Liu

In composite structures, the perfobond connector is an alternative type of shear connector which consists of a steel plate with a certain number of holes. The load–slip relationship is critical for structural analysis and numerical simulation of composite structures using perfobond connectors. In this study, push-out tests were conducted on 72 specimens to obtain the load–slip behaviors of perfobond connectors. Based on the test results, parametric study was performed to analyze the effects of changing the hole geometry, the concrete strength, the configuration of the rebar in hole, the dimensions of the perfobond rib, and the size of the concrete slab. Furthermore, the characteristics and physical meanings of the load–slip curves were analyzed, and the limits and conditions for theoretical expressions were derived. Finally, an analytical model was proposed to express the load–slip relationship of perfobond connectors covering a wide range of design variables.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 479
Author(s):  
Wei Wang ◽  
Xie-dong Zhang ◽  
Fa-xing Ding ◽  
Xi-long Zhou

High-strength bolted shear connectors (HSBSCs), which can be demounted easily and efficiently during deconstruction, are recommended to replace the conventional steel studs in steel–concrete composite beams (SCCBs) to meet the requirements of sustainable development. The existing investigations on the behavior of HSBSCs mainly focus on the positive moment area of composite beams, in which the concrete slab is in compress condition. In this paper, a three-dimensional finite element model (FEM) was developed to investigate the performance of HSBSCs subjected to inverse push-off loading. Material nonlinearities and the interactions among all components were included in the FEM. The accuracy and reliability of the proposed FEM were initially validated against the available push-off test results. Load-carrying capacity and load–slip response of the HSBSCs under inverse push-off loading were further studied by the verified FEM. A parametric study was carried out to determine the influence of the concrete strength, the diameter and tensile strength of bolt and the clearance between the concrete slab and the bolt as well as the bolt pretension on the shear performance of HSBSCs. Based on the extensive parametric analyses, design recommendations for estimating the shear load at the first slip and load-bearing resistance of HSBSCs were proposed and verified.


2018 ◽  
Vol 21 (3) ◽  
pp. 393-404
Author(s):  
Ali Farhan Hadeed ◽  
Laith Khalid Al-Hadithy ◽  
Riyadh J. Aziz

The composite opened web steel joist supported floor systems have been common for many years. It is economic and has light weight and can embed the electrical conduit, ductwork and piping, eliminating the need for these to pass under the member, consequently eliminate the height between floors. In order to study the joist strength capacity under the various conditions, it had been fabricated seven joists composed of the steel and concrete slab connected to the top chord by shear connectors (headed studs). These joist have 2820 mm length c/c of the supports and 235 mm overall depth. In the present study, six variable parameters are adopted (Studs distribution, Degree of shear connection, Degree of the web inclination, Shape of the web, Density of concrete for slab and length of the shear connector). The test results exhibited that minimum strength capacity was 160kN for light weight joist and maximum capacity was 225kN for joist of long shear connectors at failure. The results were compared by ultimate flexural model by Azmi.


2021 ◽  
Vol 295 (2) ◽  
pp. 16-26
Author(s):  
D.V. Konin ◽  

The shear connector design should be executed according to the SP 266.1325800.2016. For the different typed of welded connectors are there analytic dependences, which could be used for shear connection strength estimation. The design code also allows to use powder-actuated Z-shape shear connectors. Their bearing capacity should be proved by tests according to the GOST R 58336-2018. Inasmuch the GOST doesn't consist the test estimation approach, the authors offer the method. For the test estimation methods the test results of 15 series specimen had been used. The results were compared with estimation according to the European standard for the verification.


1986 ◽  
Vol 13 (6) ◽  
pp. 741-751 ◽  
Author(s):  
R. Basset ◽  
S. M. Uzumeri

This paper summarizes an experimental investigation into the behaviour of high strength sand – lightweight concrete columns confined with rectangular ties. Fifteen reinforced and three unreinforced specimens were tested under monotonically increasing axial compression. Variables considered in this study were the longitudinal steel distribution and tie configuration, the tie steel spacing, the amount of tie steel, and the amount of longitudinal steel.The results indicated that unconfined high-strength lightweight aggregate concrete is a brittle material. The addition of lateral confining steel significantly improved the behaviour of this material, with a large amount of lateral steel resulting in very ductile behaviour. The tie configuration and resulting distribution of longitudinal steel contributed significantly to the confinement of concrete, with well-distributed steel resulting in improved behaviour. The ratio of specimen to cylinder concrete strength was observed to be 0.98, which is much higher than the commonly assumed value of 0.85.The test results were compared with results from selected theoretical confinement models. Based on the results of this investigation, existing models for concrete confinement give unconservative results for high-strength lightweight aggregate concrete and overestimate the ductility that can be achieved with this material. Key words: columns, confinement, ductility, high-strength concretes, lightweight aggregate concretes, reinforcement, stress–strain relationships, tests, ties, toughness.


2010 ◽  
Vol 163-167 ◽  
pp. 11-15
Author(s):  
Wen Qi Hou ◽  
Mei Xin Ye ◽  
Ye Zhi Zhang

Abstract. In the presented paper, reverse push-out test method was put forward and applied in the ultimate bearing capacity experiments of studs with concrete slab in tension. Ultimate bearing capacity experiments were carried out on 22 reverse push-out specimens composed of C50 or C40 concrete, 14MnNbq steel girder and Φ22studs. Results showed that ultimate bearing capacity of studs, pu, in tensile concrete slab is controlled by concrete failur, concrete strength, studs arragement and reinforcement ratio are the main influence factors of pu. Compared with that in compressive concrete, pu of Φ22 studs in tensile concrete is reduced about 30% averagely. According to the test results, a fitted load-slip relationship curve and a regression formula of pu for studs in tensile concrete were put forward, calculated results were in good agreement with the test results.


2010 ◽  
Vol 163-167 ◽  
pp. 1403-1408
Author(s):  
Feng Liu ◽  
Gui Xuan Chen ◽  
Li Juan Li

The effects of recycled rubber powder on working abilities, density and compressive strength of high strength concrete (HSC) at room temperature were studied in this paper. The characteristics of rubberized high strength concrete (RHSC) after fire was investigated by surface observation, weight loss and retained strength testing. The sieve number of rubber powder used in test is No.40 (420μm), No.60 (250µm) and No.80 (178µm), and the content of rubber powder filled in RHSC is 1%, 2%, 3% and 4% with respect to cementation material respectively. Test results show that the increase in rubber powder content reduces the concrete strength, while the decrease in compressive strength of RHSC is less than 10% when the content of rubber powder is within 2%. RHSC with small content of rubber (1%) can restrain the spalling failure of concrete under high temperature.