The reliability of the electrical system is a fundamental study that is carried out to determine the possible deficiencies that an electrical system can have in case of failures, since a failure can cause disturbances, power cuts, and load disconnections. For this reason, Optimal Transmission Switching (OTS) with Optimal AC Power Flows (OPF-AC) is used to reduce disturbances when faults occur and minimize equipment load and disconnections, but OTS offers possible switches in order to make it possible to reduce the damage that can be done for a fault with operating limitations in voltage, power, and angular deviation. However, to have a complete study, it is proposed to use a reliability analysis through contingency ranking to know the risks that a switched system may have at the time of simultaneous or consecutive failures. In addition, a load capacity investigation is conducted to determine if the transmission lines are within their operating limits. The study presents an analysis of the behavior of the switched system and an adequate operation for the mitigation of failures in the system through the switching of transmission lines with analysis of load capacity and reliability. The results presented by the proposed methodology will be compared with Matlab’s Matpower simulation package.

2019 ◽  
Vol 2019 ◽  
pp. 1-7 ◽  
Author(s):  
Lutfi Akin

A normal mode analysis of a vibrating mechanical or electrical system gives rise to an eigenvalue problem. Faber made a fairly complete study of the existence and asymptotic behavior of eigenvalues and eigenfunctions, Green’s function, and expansion properties. We will investigate a new characterization of some class nonlinear eigenvalue problem.


2020 ◽  
Vol 1 (1) ◽  
Author(s):  
Yibo Ding ◽  
Kaiyan Zhang ◽  
Shishan Wang ◽  
Jian Guo

Electromagnetic noise has serious influence on the performance of electrical system. In addition, while multiconductor cable harnesses play an important role in transmitting electromagnetic energy or signal between devices of electrical system, they are also the major path to transmit electromagnetic noise. Crosstalk, as typical electromagnetic noise within multi-conductor cable harnesses, is an important factor which affects the efficiency of transmission. In this paper, the n+1 transmission lines (n=2, n>2) are taken as the object of research. Based on the theory of Multi-conductor Transmission Line (MTL), the transmission of electromagnetic noise in transmission line is studied, including noise of generating line (called G-line) and line receiving interference (called R-line), the latter called crosstalk. Transfer functions of electromagnetic noise of G-line and R-line are simulated using FEKO (FEldberechnung bei Korpern mit beliebiger Oberflache). Two transfer functions are obtained to investigate the severity of noise of G-line and R-line. The characteristics of the parameters are also studied. Simulation results indicate that transfer functions have tight relationship with the electrical length. When the electrical length is small, voltage loss of interference line along the transmission line is relatively small, so is the far-end crosstalk; however, when the electrical length is large, voltage loss and the far-end crosstalk is larger, and resonances at high frequency. Keywords: Electromagnetic noise; FEKO; electrical length;


Energies ◽  
2019 ◽  
Vol 12 (7) ◽  
pp. 1206 ◽  
Author(s):  
Zhengwei Shen ◽  
Yong Tang ◽  
Jun Yi ◽  
Changsheng Chen ◽  
Bing Zhao ◽  
...  

An online line switching methodology to relieve voltage violations is proposed. This novel online methodology is based on a three-stage strategy, including screening, ranking, and detailed analysis and assessment stages for high speed (online application) and accuracy. The proposed online methodology performs the tasks of rapidly identifying effective candidate lines, ranking the effective candidates, performing detailed analysis of the top ranked candidates, and supplying a set of solutions for the power system. The post-switching power systems, after executing the proposed line switching action, meet the operational and engineering constraints. The results provided by the exact Alternating Current (AC) power flow are used as a benchmark to compare the speed and accuracy of the proposed three-stage methodology. One feature of the methodology is that it can provide a set of high-quality switching solutions from which operators may choose a preferred solution. The effectiveness of the proposed online line switching methodology in providing single-line switching and multiple-line switching solutions to relieve voltage violations is evaluated on the IEEE 39-bus and 2746-bus power system. The CPU time of the proposed methodology compared with that under AC power flow constitutes a speed-up of 9905.32% on a 2746-bus power system, showing good potential for online application in a large-scale power system.


2020 ◽  
Vol 14 (1) ◽  
pp. 21-26
Author(s):  
S. SKRYPNYK ◽  
◽  
A. SHEINA ◽  

Most failures in electrical installations are caused by short circuits (short circuits), which occur as a result of a failure in the electrical strength of the insulation of the conductive parts. A short circuit is an electrical connection of two points of an electric circuit with different values of potential, which is not provided by the design of the device, which interferes with its normal operation. Short circuits may result from a failure of the insulation of the current-carrying elements or the mechanical contact of the non- insulated elements. Also called a short circuit is a condition where the load resistance is less than the internal resistance of the power source. The reasons for such violations are various: aging of insulation, breakages of wires of overhead transmission lines, mechanical damages of isolation of cable lines at ground works, lightning strikes in the transmission line and others. Most often, short-circuits occur through transient resistance, such as through the resistance of an electric arc that occurs at the point of damage to the insulation. Sometimes there are metallic short circuits in which the resistance of the electric arc is very small. The study of short circuits in the power grid is a major step in the design of modern electrical networks. The research is conducted using computer software, first by modeling the system and then simulating errors. A malfunction usually leads to an increase in the current flowing in the lines, and failure to provide reliable protection can result in damage to the power unit. Thus, short-circuit calculations are the primary consideration when designing, upgrading, or expanding a power system. The three-phase short circuit is the least likely. However, in many cases, the three-phase short circuit is associated with the most severe consequences, as it causes the highest power imbalances on the shafts of the generators. The study of transients begins with the mode of three-phase closure due to its relative simplicity in comparison with other types of asymmetry. In most cases, the analysis and calculation of the transient regime of the electrical system involves the preparation of a calculated scheme of substitution, in which the parameters of its elements are determined in named or relative units. The electrical substitution circuitry is used to further study the transients in the power system. The definition of electrical and electromagnetic quantities in relative units is widely used in the theory of electric machines. This is because it significantly simplifies the theoretical calculations and gives the results a generalized view in the practical calculations of currents and residual voltages at the short circuit. By the relative value of any value is understood as its relation to another value of the same name, taken as the base. So, before presenting any quantities in relative units, we need to choose the basic units. In the electrical system with increased voltages, the overall load capacity of the network increases, which in turn makes it possible to supply high-quality electrical energy over a greater distance. In the process of comparing the type of transmission lines, it should be noted that the advantages of the cable transmission line. According to the results of the calculation of short-circuit currents, it can be concluded that in networks with a larger line cross-section and a higher voltage, the short-circuit currents are larger. Thus, during the transition of the electric networks to the higher voltage class of 20 kV, the currents of the KZ increased by 43% compared to the 6 kV electric network. This analysis shows that the importance of reliable power supply in the power supply system for high voltage classes must be high and have equipment to prevent emergencies. In the future, it is planned to develop a systematic calculation of short-circuit currents for a number of transmission lines and to conduct mathematical modeling in the system of applications for the study of transient processes at short circuits.