scholarly journals Recovery Act: Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground Source Water Loops

2013 ◽  
Author(s):  
Mark Jarrell
2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Silvia Cocchi ◽  
Sonia Castellucci ◽  
Andrea Tucci

The need to address climate change caused by greenhouse gas emissions attaches great importance to research aimed at using renewable energy. Geothermal energy is an interesting alternative concerning the production of energy for air conditioning of buildings (heating and cooling), through the use of geothermal heat pumps. In this work a model has been developed in order to simulate an air conditioning system with geothermal heat pump. A ground source heat pump (GSHP) uses the shallow ground as a source of heat, thus taking advantage of its seasonally moderate temperatures. GSHP must be coupled with geothermal exchangers. The model leads to design optimization of geothermal heat exchangers and to verify the operation of the geothermal plant.


2017 ◽  
Vol 27 (6) ◽  
pp. 805-817 ◽  
Author(s):  
Byung C. Kwag ◽  
Moncef Krarti

Ground medium can be utilized as a direct energy source to heat and cool buildings. In particular, ground source heat pump systems take advantage of the year-round mild deep earth temperature without a significant reliance on any external energy sources. However, the high installation cost of ground source heat pumps associated with high drilling cost of vertical boreholes often make these systems less cost-effective compared to conventional heating and cooling systems. Thermo-active foundations can be a viable solution to reduce ground source heat pump high installation costs by embedding heat exchangers within building foundation structures. Compared to ground source heat pumps, only limited analyses and research studies have been reported for thermo-active foundations especially for the US climates. In particular, no specific design guidelines have been reported for thermo-active foundations especially for US climates. In this paper, a simplified design approach was developed and applied for specifying geothermal heat pump size and heat exchanger loop length to meet all or part of building heat and cooling thermal loads. The developed guidelines would thus provide a proper design guide for installation of thermo-active foundations for heating and cooling of both US residential and commercial buildings.


Author(s):  
Nazar F. Antwan ◽  
Iyd E. Maree

Geothermal heat pumps with ground source heat exchangers have been widely used for heating and cooling homes as well as for domestic water heating. A study on a small house in Erbil-Iraq was conducted to assess energy savings when using GHPs with closed loop ground source heat exchangers as compared with air-to-air heat pumps. Local climate conditions and soil properties of Erbil located in the north of Iraq were used. The simulation was performed using TRNSYS-16 software. The results of this study show that we can reduce the energy used for heating and cooling by 39% during annual when using GHP. The simulation also showed that the average COP for heating is 2.9 and for cooling is 2.6 when using air to air heat pumps and the average COP for heating is 5.6 and 3.6 for cooling when using GHP. This reduction in energy reduces the CO2 emission as it reduces energy consumption.


Author(s):  
Xinli Lu ◽  
David R. Larson ◽  
Thomas R. Holm

Groundwater source heat pumps exploit the difference between the ground surface temperature and the nearly constant temperature of shallow groundwater. This project characterizes two areas for geothermal heating and cooling potential, Mason County in central Illinois and the American Bottoms area in southwestern Illinois. Both areas are underlain by thick sand and gravel aquifers and groundwater is readily available. Weather data, including monthly high and low temperatures and heating and cooling degree days, were compiled for both study areas. The heating and cooling requirements for a single-family house were estimated using two independent models that use weather data as input. The groundwater flow rates needed to meet these heating and cooling requirements were calculated using typical heat pump coefficient of performance values. The groundwater in both study areas has fairly high hardness and iron concentrations and is close to saturation with calcium and iron carbonates. Using the groundwater for cooling may induce the deposition of scale containing one or both of these minerals.


Author(s):  
Mohammad Omar Temori ◽  
František Vranay

In this work, a mini review of heat pumps is presented. The work is intended to introduce a technology that can be used to income energy from the natural environment and thus reduce electricity consumption for heating and cooling. A heat pump is a mechanical device that transfers heat from one environmental compartment to another, typically against a temperature gradient (i.e. from cool to hot). In order to do this, an energy input is required: this may be mechanical, electrical or thermal energy. In most modern heat pumps, electrical energy powers a compressor, which drives a compression - expansion cycle of refrigerant fluid between two heat exchanges: a cold evaporator and a warm condenser. The efficiency or coefficient of performance (COP), of a heat pump is defined as the thermal output divided by the primary energy (electricity) input. The COP decreases as the temperature difference between the cool heat source and the warm heat sink increases. An efficient ground source heat pump (GSHP) may achieve a COP of around 4. Heat pumps are ideal for exploiting low-temperature environmental heat sources: the air, surface waters or the ground. They can deliver significant environmental (CO2) and cost savings.


2020 ◽  
Author(s):  
Eric Wagner ◽  
Benjamin McDaniel ◽  
Dragoljub Kosanovic

Ground-source heat pump (GSHP) systems have been implemented at large scales on several university campuses to provide heating and cooling. In this study, we test the idea that a GSHP system, as a replacement for an existing Combined Heat and Power (CHP) heating system coupled with conventional cooling systems, could reduce CO2 emissions, and provide a cost benefit to a university campus. We use the existing recorded annual heating and cooling loads supplied by the current system and an established technique of modeling the heat pumps and borehole heat exchangers (BHEs) using a TRNSYS model. The GSHP system is modeled to follow the parameters of industry standards and sized to provide an optimal balance of capital and operating costs. Results show that despite a decrease in heating and cooling energy usage and CO2 emissions are achieved, a significant increase in electric demand and purchased electricity result in an overall cost increase. These results highlight the need for thermal energy storage, onsite distributed energy resources and/or demand response in cases where electric heat pumps are used to help mitigate electric demand during peak periods.


Author(s):  
Birol I. Kilkis

Effective utilization of low-enthalpy energy resources in heating, ventilating, and air-conditioning (HVAC) of sustainable buildings require a careful optimization to assure the most economical coupling of HVAC systems with low-enthalpy energy resources. In one of the two separate prior studies an optimization algorithm for the optimal coupling of heat pumps and radiant panel heating and cooling systems was developed. In the second prior study an optimization algorithm for driving ground source heat pumps with wind turbines was developed. In this study these two algorithms were combined for a compound utilization of alternative energy resources. This paper describes the optimization algorithms, emphasizes their importance in achieving a cost effective combined application, and discusses the results obtained from the examples given.


Energies ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2496 ◽  
Author(s):  
Laura Carnieletto ◽  
Borja Badenes ◽  
Marco Belliardi ◽  
Adriana Bernardi ◽  
Samantha Graci ◽  
...  

The design of ground source heat pumps is a fundamental step to ensure the high energy efficiency of heat pump systems throughout their operating years. To enhance the diffusion of ground source heat pump systems, two different tools are developed in the H2020 research project named, “Cheap GSHPs”: A design tool and a decision support system. In both cases, the energy demand of the buildings may not be calculated by the user. The main input data, to evaluate the size of the borehole heat exchangers, is the building energy demand. This paper presents a methodology to correlate energy demand, building typologies, and climatic conditions for different types of residential buildings. Rather than envelope properties, three insulation levels have been considered in different climatic conditions to set up a database of energy profiles. Analyzing European climatic test reference years, 23 locations have been considered. For each location, the overall energy and the mean hourly monthly energy profiles for heating and cooling have been calculated. Pre-calculated profiles are needed to size generation systems and, in particular, ground source heat pumps. For this reason, correlations based on the degree days for heating and cooling demand have been found in order to generalize the results for different buildings. These correlations depend on the Köppen–Geiger climate scale.


Author(s):  
Peter B. Whittaker ◽  
Xiaolin Wang ◽  
Klaus Regenauer-Lieb ◽  
David Blair ◽  
Hui Tong Chua

Geothermal heat is a sustainable form of alternative energy, commonly associated with the production of electricity along tectonic plate boundaries and in volcanically active zones. Outside of these special regions however it is rare to find a geothermal gradient high enough to achieve pay back on projects for generating electricity. On the other hand regions containing sedimentary aquifers are far more common and these aquifers frequently have a sufficiently high temperature gradient to make direct use of the thermal energy attractive. Meanwhile highly permeable aquifers occurring at shallow depths are possible sources for cooling water or can be both heat sources and sinks when used in combination with heat pumps. We provide a case study for the use of thermally driven absorption chillers on the University of Western Australia campus in Perth and discuss two ongoing projects: one for the heating and cooling of the offices of the Australian Resources Research Council using a reversible heat pump and the other the climate control of the planned Australian International Gravitational Observatory.