scholarly journals TESTING PILOT-SCALE BORON-DOPED DIAMOND ELECTRODES (BDDE)-BASED ELECTROCHEMICAL MODULE FOR DRINKING WATER TREATMENT

2018 ◽  
Author(s):  
Adina Pacala ◽  
◽  
Katalin Bodor ◽  
Ilie Vlaicu ◽  
Florica Manea ◽  
...  
2010 ◽  
Vol 5 (2) ◽  
Author(s):  
M.E.H. Bergmann ◽  
J. Rollin ◽  
A.S. Koparal

Studying electrolysis processes in drinking water disinfection it was found that chlorate and perchlorate can be formed at high extent on several electrode materials. Formation potential differs by orders of magnitude comparing mixed oxide (MIO), Pt and boron doped diamond (BDD) anodes. Highest concentrations were found using the doped diamond electrodes. Extended studies showed that chlorate and perchlorate may be formed also in other processes of so-called Advanced Oxidation. Therefore, the authors propose both components as new inorganic assessment criterions in environmentally-oriented water treatment.


2019 ◽  
Vol 24 (1) ◽  
pp. 135-163
Author(s):  
Jader Martínez Girón ◽  
Jenny Vanessa Marín-Rivera ◽  
Mauricio Quintero-Angel

Population growth and urbanization pose a greater pressure for the treatment of drinking water. Additionally, different treatment units, such as decanters and filters, accumulate high concentrations of iron (Fe) and manganese (Mn), which in many cases can be discharged into the environment without any treatment when maintenance is performed. Therefore, this paper evaluates the effectiveness of vertical subsurface wetlands for Fe and Mn removal from wastewater in drinking water treatment plants, taking a pilot scale wetland with an ascending gravel bed with two types of plants: C. esculenta and P. australis in El Hormiguero (Cali, Colombia), as an example. The pilot system had three upstream vertical wetlands, two of them planted and the third one without a plant used as a control. The wetlands were arranged in parallel and each formed by three gravel beds of different diameter. The results showed no significant difference for the percentage of removal in the three wetlands for turbidity (98 %), Fe (90 %), dissolved Fe (97 %) and Mn (98 %). The dissolved oxygen presented a significant difference between the planted wetlands and the control. C. esculenta had the highest concentration of Fe in the root with (103.5 ± 20.8) µg/g ; while P. australis had the highest average of Fe concentrations in leaves and stem with (45.7 ± 24) µg/g and (41.4 ± 9.1) µg/g, respectively. It is concluded that subsurface wetlands can be an interesting alternative for wastewater treatment in the maintenance of drinking water treatment plants. However, more research is needed for the use of vegetation or some technologies for the removal or reduction of the pollutant load in wetlands, since each drinking water treatment plant will require a treatment system for wastewater, which in turn requires a wastewater treatment system as well.


2020 ◽  
Vol 382 ◽  
pp. 123044 ◽  
Author(s):  
Zhenqi Du ◽  
Ruibao Jia ◽  
Congcong Li ◽  
Pengwei Cui ◽  
Wuchang Song ◽  
...  

2021 ◽  
Author(s):  
Nick Dimas

Drinking Water Treatment Plants employ biofiltration systems to increase water quality through nutrient reduction. Microbial biofilms housed in biofilter media, are responsible for nutrient uptake and biodegradation. The purpose of this study was to re-evaluate the function and efficiency of biofilter media and investigate seasonal changes in the microbial populations. TOC and DO were more reduced in Granular Activated Carbon (GAC) media than in anthracite. Heterotrophic plate counts (HPC) were conducted to establish seasonal trends on microbial population. PCR-amplified 16S rRNA fragments were sequenced to compare microbial communities. Summer samples have higher HPC than winter samples. Summer samples yielded a reduction in microbial diversity and no detectable overlap with winter samples. Confocal microscopy conducted to qualitatively visualize the structure of biofilms was complemented by quantitative COMSTAT analysis showing GAC with double the biomass due to a greater level of attachment sites. GAC outcompetes anthracite in chemical adsorption and biological activity.


Water ◽  
2020 ◽  
Vol 12 (11) ◽  
pp. 3275
Author(s):  
Philipp Otter ◽  
Katharina Mette ◽  
Robert Wesch ◽  
Tobias Gerhardt ◽  
Frank-Marc Krüger ◽  
...  

A large variety of Advanced Oxidation Processes (AOPs) to degrade trace organic compounds during water treatment have been studied on a lab scale in the past. This paper presents the combination of inline electrolytic chlorine generation (ECl2) with low pressure UV reactors (UV/ECl2) in order to allow the operation of a chlorine-based AOP without the need for any chlorine dosing. Lab studies showed that from a Free Available Chlorine (FAC) concentration range between 1 and 18 mg/L produced by ECl2 up to 84% can be photolyzed to form, among others, hydroxyl radicals (OH) with an UV energy input of 0.48 kWh/m3. This ratio could be increased to 97% by doubling the UV energy input to 0.96 kWh/m3 and was constant throughout the tested FAC range. Also the achieved radical yield of 64% did not change along the given FAC concentration range and no dependence between pH 6 and pH 8 could be found, largely simplifying the operation of a pilot scale system in drinking water treatment. Whereas with ECl2 alone only 5% of benzotriazoles could be degraded, the combination with UV improved the degradation to 89%. Similar results were achieved for 4-methylbenzotriazole, 5-methylbenzotriazole and iomeprol. Oxipurinol and gabapentin were readily degraded by ECl2 alone. The trihalomethanes values were maintained below the Germany drinking water standard of 50 µg/L, provided residual chlorine concentrations are kept within the permissible limits. The here presented treatment approach is promising for decentralized treatment application but requires further optimization in order to reduce its energy requirements.


Sign in / Sign up

Export Citation Format

Share Document