Clonal variation in reproductive response to temperature by a potential bulking control agent, Lecane inermis (Rotifera)

2011 ◽  
Vol 64 (2) ◽  
pp. 403-408 ◽  
Author(s):  
Edyta Fiałkowska ◽  
Wioleta Kocerba ◽  
Agnieszka Pajdak-Stós ◽  
Beata Klimek ◽  
Janusz Fyda

The novel idea of using rotifers Lecane inermis (Rotifera, Monogononta) as a tool to overcome activated sludge bulking generates an on-going need to study rotifer biology. The results of biological research on rotifers can serve to improve the method so that it can be most effective when applied in treatment plants. The aim of this study was to test the effect of temperature on four selected rotifer clones originating from different treatment plants. The rate of population development from a single individual (parthenogenetic female) during a 10-day experiment was measured at three temperatures: 8, 15 and 20 °C. The temperatures used reflect the annual temperature distribution in the majority of municipal wastewater treatment plants in the temperate zone. The growth rate coefficient (r) and doubling time (tD) were calculated for each clone. Under the most favourable conditions (20 °C), r values varied between 0.41 and 0.47 d and doubling time between 1.5 and 1.7 d. At a temperature of 15 °C, the doubling time was approximately two times longer (2.5–3.4 d). The strongest intraspecific variations were observed at the lowest temperature of 8 °C. At this temperature, one of the clones almost failed to proliferate, and another exhibited a doubling time of 7.9 d. The doubling times were a few times greater for the remaining two clones (60 d for Lk1, 33.3 d for Lk4). These results could be very useful in predicting the chances that the rotifers would survive in a biological reactor in a wastewater treatment plant at the temperatures used in these reactors.

2021 ◽  
Vol 13 (13) ◽  
pp. 7198
Author(s):  
Eleni P. Tsiakiri ◽  
Aikaterini Mpougali ◽  
Ioannis Lemonidis ◽  
Christos A. Tzenos ◽  
Sotirios D. Kalamaras ◽  
...  

Wastewater treatment plants have been traditionally developed for the aerobic degradation of effluent organic matter, and are associated with high energy consumption. The adoption of sustainable development targets favors the utilization of every available energy source, and the current work aims at the identification of biomethane potential from non-conventional sources derived from municipal wastewater treatment processes. Byproducts derived from the primary treatment process stage were collected from four sewage treatment plants in Greece with great variation in design capacity and servicing areas with wide human activities, affecting the quality of the influents and the corresponding primary wastes. The samples were characterized for the determination of their solids and fats content, as well as the concentration of leached organic matter and nutrients, and were subjected to anaerobic digestion treatment for the measurement of their biomethane production potential according to standardized procedures. All samples exhibited potential for biogas utilization, with screenings collected from a treatment plant receiving wastewater from an area with combined rural and agro-industrial activities presenting the highest potential. Nevertheless, these samples had a methanogens doubling time of around 1.3 days, while screenings from a high-capacity unit proved to have a methanogens doubling time of less than 1 day. On the other hand, floatings from grit chambers presented the smallest potential for energy utilization. Nevertheless, these wastes can be utilized for energy production, potentially in secondary sludge co-digestion units, converting a treatment plant from an energy demanding to a zero energy or even a power production process.


1994 ◽  
Vol 30 (4) ◽  
pp. 125-132 ◽  
Author(s):  
D. Carnimeo ◽  
E. Contini ◽  
R. Di Marino ◽  
F. Donadio ◽  
L. Liberti ◽  
...  

The pilot investigation on the use of UV as an alternative disinfectant to NaOCI was started in 1992 at Trani (South Italy) municipal wastewater treatment plant (335 m3/h). The results collected after six months continuous operation enabled us to compare UV and NaOCl disinfection effectiveness on the basis of secondary effluent characteristics, quantify photoreactivation effects, evidence possible DBP formation and assess costs.


1997 ◽  
Vol 35 (6) ◽  
pp. 63-70 ◽  
Author(s):  
Yoshimasa Watanabe ◽  
Yoshihiko Iwasaki

This paper describes a pilot plant study on the performance of a hybrid small municipal wastewater treatment system consisting of a jet mixed separator(JMS) and upgraded RBC. The JMS was used as a pre-treatment of the RBC instead of the primary clarifier. The treatment capacity of the system was fixed at 100 m3/d, corresponding to the hydraulic loading to the RBC of 117 L/m2/d. The effluent from the grid chamber at a municipal wastewater treatment plant was fed into the hybrid system. The RBC was operated using the electric power produced by a solar electric generation panel with a surface area of 8 m2 under enough sunlight. In order to reduce the organic loading to the RBC, polyaluminium chloride(PAC) was added to the JMS influent to remove the colloidal and suspended organic particles. At the operational condition where the A1 dosage and hydraulic retention time of the JMS were fixed at 5 g/m3 and 45 min., respectively, the average effluent water quality of hybrid system was as follows: TOC=8 g/m3, Total BOD=8 g/m3, SS=8 g/m3, Turbidity=6 TU, NH4-N=7 g/m3, T-P=0.5 g/m3. In this operating condition, electric power consumption of the RBC for treating unit volume of wastewater is only 0.07 KWH/m3.


Water ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 1339
Author(s):  
Javier Bayo ◽  
Sonia Olmos ◽  
Joaquín López-Castellanos

This study investigates the removal of microplastics from wastewater in an urban wastewater treatment plant located in Southeast Spain, including an oxidation ditch, rapid sand filtration, and ultraviolet disinfection. A total of 146.73 L of wastewater samples from influent and effluent were processed, following a density separation methodology, visual classification under a stereomicroscope, and FTIR analysis for polymer identification. Microplastics proved to be 72.41% of total microparticles collected, with a global removal rate of 64.26% after the tertiary treatment and within the average retention for European WWTPs. Three different shapes were identified: i.e., microfiber (79.65%), film (11.26%), and fragment (9.09%), without the identification of microbeads despite the proximity to a plastic compounding factory. Fibers were less efficiently removed (56.16%) than particulate microplastics (90.03%), suggesting that tertiary treatments clearly discriminate between forms, and reporting a daily emission of 1.6 × 107 microplastics to the environment. Year variability in microplastic burden was cushioned at the effluent, reporting a stable performance of the sewage plant. Eight different polymer families were identified, LDPE film being the most abundant form, with 10 different colors and sizes mainly between 1–2 mm. Future efforts should be dedicated to source control, plastic waste management, improvement of legislation, and specific microplastic-targeted treatment units, especially for microfiber removal.


Proceedings ◽  
2021 ◽  
Vol 52 (1) ◽  
pp. 3
Author(s):  
Luis F. Carmo-Calado ◽  
Roberta Mota-Panizio ◽  
Gonçalo Lourinho ◽  
Octávio Alves ◽  
I. Gato ◽  
...  

The technical-economic analysis was carried out for the production of sludge-derived fuel from a municipal wastewater treatment plant (WWTP). The baseline for the analysis consists of a sludge drying plant, processing 6 m3 of sludge per day and producing a total of about 1 m3 of combustible material with 8% of moisture and a higher calorific power of 18.702 MJ/kg. The transformation of biofuel into energy translates into an electricity production of about 108 kW per 100 kg of sludge. The project in the baseline scenario demonstrated feasibility with a payback time of about six years.


2000 ◽  
Vol 41 (7) ◽  
pp. 31-37 ◽  
Author(s):  
E. Carraro ◽  
E. Fea ◽  
S. Salva ◽  
G. Gilli

The aim of this study was to assess the impact of a municipal wastewater treatment plant (MWTP) on the occurrence of Cryptosporidium oocysts and Giardia cysts in the receiving water. All MWTP effluent samples were Giardia and Cryptosporidium contaminated, although low mean values were found for both parasites (0.21±0.06 oocysts/L; 1.39±0.51 cysts/L). Otherwise, in the raw sewage a greater concentration was detected (4.5±0.3 oocysts/L; 53.6±6.8 cysts/L). The major occurrence of Giardia over Cryptosporidium, both in the influent and in the effluent of the MWTP, is probably related to the human sewage contribution to the wastewater. Data on protozoa contamination of the receiving water body demonstrated similar concentrations in the samples collected before (0.21±0.07 oocysts/L; 1.31±0.38 cysts/L) and after (0.17±0.09 oocysts/L and 1.01±1.05 cysts/L) the plant effluent discharge. The results of this study suggest that the MWTP has no impact related to Giardia and Cryptosporidium river water contamination, and underline the need for investigation into the effectiveness of these protozoa removal by less technologically advanced MWTPs which are the most widespread and could probably show a lower ability to reduce protozoa.


Sign in / Sign up

Export Citation Format

Share Document