The limits and ultimate possibilities of technology of the activated sludge process

2008 ◽  
Vol 58 (8) ◽  
pp. 1671-1677 ◽  
Author(s):  
A. F. van Nieuwenhuijzen ◽  
A. G. N. van Bentem ◽  
A. Buunnen ◽  
B. A. Reitsma ◽  
C. A. Uijterlinde

The (low loaded) biological nutrient removing activated sludge process is the generally accepted and applied municipal wastewater treatment method in the Netherlands. The hydraulical and biological flexibility, robustness and cost efficiency of the process for advanced removal of nutrients like nitrogen and phosphorus without (too much) chemicals results in a wide application of the activated sludge process within Dutch waterboards. Presumably, wastewater treatment plants will have to contribute to the improvement of the quality of the receiving surface waters by producing cleaner effluent. In this perspective, the Dutch research organisation STOWA initiated a research project entitled “The Boundaries of the Activated Sludge Process” to investigate the possibilities and limitations of activated sludge processes to improve the effluent quality. It is concluded that the activated sludge process as applied and operated at WWTP's in the Netherlands has the potential to perform even better than the current effluent discharge standards (10 mg Ntotal/l and 1 mg Ptotal/l). Reaching the B-quality effluent (<5mg Ntotal/l and <0.3 mg Ptotal/l) will be possible at almost all WWTPs without major adjustments under the conditions that:   the sludge load is below 0.06 kg BOD/kg TSS.d   the internal recirculation is above 20   the BOD/N ratio of the influent is above 3. Complying with the A-quality effluent (<2.2 Ntotal/l and <0.15 mg Ptotal/l) seems to be difficult (but not impossible) and requires more attention and insight into the activated sludge process. Optimisation measures to reach the A-quality effluent are more thorough and are mostly only achievable by additional construction works (addition of activated sludge volume, increasing recirculation capacity, etc.). It is furthermore concluded that the static HSA-results are comparable to the dynamic ASM-results. So, for fast determinations of the limits of technology of different activated sludge processes static modelling seems to by sufficient.

Author(s):  
A. Kuokkanen ◽  
K. Blomberg ◽  
A. Mikola ◽  
M. Heinonen

Abstract Nitrous oxide emissions can contribute significantly to the carbon footprint of municipal wastewater treatment plants even though emissions from conventional nitrogen removal processes are assumed to be moderate. An increased risk for high emissions can occur in connection with process disturbances and nitrite (NO2−) accumulation. This work describes the findings at a large municipal wastewater treatment plant where the levels of NO2− in the activated sludge process effluent were spontaneously and strongly increased on several activated sludge lines which was suspected to be due to shortcut nitrogen removal that stabilized for several months. The high NO2− levels were linked to a dramatic increase in nitrous oxide (N2O) emissions. As much as over 20% of the daily influent nitrogen load was emitted as N2O. These observations indicate that highly increased NO2− levels can occur in conventional activated sludge processes and result in high nitrous oxide emissions. They also raise questions concerning the risk of increased greenhouse gas (GHG) emissions of the nitritation-denitritation processes – although the uncontrolled nature of the event described here must be taken into consideration – and underline the importance of continuous monitoring and control of N2O emissions.


2006 ◽  
Vol 53 (4-5) ◽  
pp. 357-366 ◽  
Author(s):  
Y. Okayasu ◽  
H. Tanaka ◽  
T. Inui ◽  
Y. Tanaka

The effect of potassium cyanide (KCN) on nitrification processes in municipal wastewater treatment plants was studied by batch nitrification tests, which indicated that nitrification processes tend to be inhibited at a lower KCN concentration than the present discharge standard to sewerage. The experiment of the biosensor using nitrifying bacteria was also conducted for continuous monitoring of nitrification inhibitor in influent wastewater, and demonstrated that the biosensor can detect KCN at as low as EC10 of the abovementioned batch nitrification test. Moreover, to determine the effectiveness of application of the biosensor to avoid the impact of KCN due to an accidental spillage in a sewerage system, KCN was intentionally injected into the experimental models of activated sludge process equipped both with and without the biosensor. The model with the biosensor that could detect KCN could divert the wastewater including KCN to a refuge tank, which resulted in the avoidance of upset of the activated sludge process. On the other hand, the model without the biosensor was upset in the nitrification process due to KCN. Such differences demonstrate the effectiveness of the biosensor applied to countermeasures of an accidental spillage of toxic chemicals to avoid upset of nitrification in municipal wastewater treatment plants.


1994 ◽  
Vol 30 (4) ◽  
pp. 211-214 ◽  
Author(s):  
E. Brands ◽  
M. Liebeskind ◽  
M. Dohmann

This study shows a comparison of important parameters for dynamic simulation concerning the highrate and low-rate activated sludge tanks of several municipal wastewater treatment plants. The parameters for the dynamic simulation of the single-stage process are quite well known, but parameters for the high-ratellow-rate activated sludge process are still missi ng, although a considerable number of wastewater treatment plants are designed and operated that way. At present any attempt to simulate their operation is restricted to the second stage due to missing data concerning growth rate, decay rate, yield coefficient and others.


1998 ◽  
Vol 38 (1) ◽  
pp. 303-310 ◽  
Author(s):  
V. Naidoo ◽  
V. Urbain ◽  
C. A. Buckley

Denitrification kinetics and wastewater characterization of eight different plants in Europe are discussed. Denitrification batch tests revealed three distinct rates except in the cases of Plaisir, Rostock and Orense where 4 rates were observed. The latter three plants revealed atypical rapid initial rates which were between 7 and 21 mgN/gVSS.h. All denitrification kinetics under non-limiting carbon conditions revealed fast first rates which ranged between 3.0 and 7.3 mgN/gVSS.h. Acetate was used to simulate denitrification kinetics with readily biodegradable COD present. Two subsequent rates were observed. Rates 2 and 3 ranged between 2 and 3 mgN/gVSS.h, and 1 and 2 mgN/gVSS.h, respectively. The RBCOD fraction varied between 10 and 19%, except for one of the plants where the value determined was 7%.


2020 ◽  
Vol 15 (2) ◽  
pp. 515-527
Author(s):  
L. Desa ◽  
P. Kängsepp ◽  
L. Quadri ◽  
G. Bellotti ◽  
K. Sørensen ◽  
...  

Abstract Many wastewater treatment plants (WWTP) in touristic areas struggle to achieve the effluent requirements due to seasonal variations in population. In alpine areas, the climate also determines a low wastewater temperature, which implies long sludge retention time (SRT) needed for the growth of nitrifying biomass in conventional activated sludge (CAS). Moreover, combined sewers generate high flow and dilution. The present study shows how the treatment efficiency of an existing CAS plant with tertiary treatment can be upgraded by adding a compact line in parallel, consisting of a Moving Bed Biofilm Reactor (MBBR)-coagulation-flocculation-disc filtration. This allows the treatment of influent variations in the MBBR and a constant flow supply to the activated sludge. The performance of the new 2-step process was comparable to that of the improved existing one. Regardless significant variations in flow (10,000–25,000 m3/d) and total suspended solids (TSS) (50–300 mg/L after primary treatment) the effluent quality fulfilled the discharge requirements. Based on yearly average effluent data, TSS were 11 mg/L, chemical oxygen demand (COD) 27 mg/L and total phosphorus (TP) 0.8 mg/L. After the upgrade, ammonium nitrogen (NH4-N) dropped from 4.9 mg/L to 1.3 mg/L and the chemical consumption for phosphorus removal was reduced.


Membranes ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 421
Author(s):  
Dimitra C. Banti ◽  
Michail Tsangas ◽  
Petros Samaras ◽  
Antonis Zorpas

Membrane bioreactor (MBR) systems are connected to several advantages compared to the conventional activated sludge (CAS) units. This work aims to the examination of the life cycle environmental impact of an MBR against a CAS unit when treating municipal wastewater with similar influent loading (BOD = 400 mg/L) and giving similar high-quality effluent (BOD < 5 mg/L). The MBR unit contained a denitrification, an aeration and a membrane tank, whereas the CAS unit included an equalization, a denitrification, a nitrification, a sedimentation, a mixing, a flocculation tank and a drum filter. Several impact categories factors were calculated by implementing the Life Cycle Assessment (LCA) methodology, including acidification potential, eutrophication potential, global warming potential (GWP), ozone depletion potential and photochemical ozone creation potential of the plants throughout their life cycle. Real data from two wastewater treatment plants were used. The research focused on two parameters which constitute the main differences between the two treatment plants: The excess sludge removal life cycle contribution—where GWPMBR = 0.50 kg CO2-eq*FU−1 and GWPCAS = 2.67 kg CO2-eq*FU−1 without sludge removal—and the wastewater treatment plant life cycle contribution—where GWPMBR = 0.002 kg CO2-eq*FU−1 and GWPCAS = 0.14 kg CO2-eq*FU−1 without land area contribution. Finally, in all the examined cases the environmental superiority of the MBR process was found.


2013 ◽  
Vol 20 (1) ◽  
pp. 199-208 ◽  
Author(s):  
Marketa Julinova ◽  
Jan Kupec ◽  
Roman Slavik ◽  
Maria Vaskova

Abstract A synthetic polymer, polyvinylpyrrolidone (PVP - E 1201) primarily finds applications in the pharmaceutical and food industries due to its resistance and zero toxicity to organisms. After ingestion, the substance passes through the organism unchanged. Consequently, it enters the systems of municipal wastewater treatment plants (WWTP) without decomposing biologically during the waste treatment process, nor does it attach (through sorption) to particles of activated sludge to any significant extent, therefore, it passes through the system of a WWTP, which may cause the substance to accumulate in the natural environment. For this reason the paper investigates the potential to initiate aerobic biodegradation of PVP in the presence of activated sludge from a municipal wastewater treatment plant. The following agents were selected as the initiators of the biodegradation process - co-substrates: acrylamide, N-acethylphenylalanine and 1-methyl-2-pyrrolidone, a substance with a similar structure to PVP monomer. The biodegradability of PVP in the presence of co-substrates was evaluated on the basis of biological oxygen demand (BOD) as determined via a MicroOxymax O2/CO2/CH4 respirometer. The total substrate concentration in the suspension equaled 400 mg·dm-3, with the ratio between PVP and the cosubstrate being 1:1, while the concentration of the dry activated sludge was 500 mg·dm-3. Even though there was no occurrence of a significant increase in the biodegradation of PVP alone in the presence of a co-substrate, acrylamide appeared to be the most effective type of co-substrate. Nevertheless, a recorded decrease in the slope of biodegradation curves over time may indicate that a process of primary decomposition was underway, which involves the production of metabolites that inhibit activated sludge microorganisms. The resulting products are not identified at this stage of experimentation.