Two Algorithms for Variable Power Control of Heat-Balance Sap Flow Gauges under High Flow Rates

2006 ◽  
Vol 98 (3) ◽  
pp. 830-838 ◽  
Author(s):  
Julie M. Tarara ◽  
John C. Ferguson
1995 ◽  
Vol 75 (1) ◽  
pp. 99-103 ◽  
Author(s):  
C. S. Tan ◽  
B. R. Buttery

Using heat-balance stem flow gauges, we were able to measure directly and continuously the sap flow rates in two pairs of soybean [Glycine max (L.) Merr.] isolines differing in stomatal frequency. Plants with high stomatal frequency transpired significantly more water than the low stomatal frequency plants at high soil moisture levels. Under low soil moisture levels, the water use rate decreased greatly for the high stomatal frequency plants. Plants with low stomatal frequency were able to maintain greater sap flow rates than those with high stomatal frequency. Higher leaf temperatures associated with the low stomatal frequency plants were likely due to lower transpiration rates which reduced evaporative cooling especially under well-watered conditions. Key words:Glycine max (L.) Merr., transpiration, water deficits


HortScience ◽  
1990 ◽  
Vol 25 (9) ◽  
pp. 1073a-1073
Author(s):  
Mark A. Rose ◽  
John W. White ◽  
Joel L. Cuello

Recently developed stem flow gauges that allow for direct, accurate, non-invasive, and continuous measurement of plant sap flow rates have not been used to monitor transpiration of floricultural plants grown in greenhouses.A Dynamax SGA10 heat-balance sap-flow sensor was mounted on a potted rose plant's main stem containing a total leaf area of 0.52 m in order to monitor transpiration. The sensor was connected to a CR21X Micrologger for data calculation and temporary storage. The results showed average midday sap-flow rates range from 20-30 g·hr-1 to 50-70 g·hr-1 at low and high levels of PPF, respectively. Nighttime levels of 4-7 g·hr-1 persisted throughout early winter trials. Monitoring transpiration of the same rose stem using a lysimeter revealed a significant linear correlation (r2 = 0.999) between the lysimeter and the stem flow gauge values.In the future, research will be conducted with the gauge to investigate relationships between microclimatic variables, photosynthesis, and transpiration.


2005 ◽  
Vol 32 (7) ◽  
pp. 599 ◽  
Author(s):  
Kathy Steppe ◽  
Raoul Lemeur ◽  
Diego Dierick

Results from measurement of sap flow by heat balance sensors on the stem of a young oak tree (Quercus robur L.) revealed that thermal disequilibrium (i.e. heat storage) within the heated stem segment can introduce considerable errors in the measured sap-flow rates. The magnitude, sign and significance of these errors depend on the sap-flow rate and on the relationship between stem temperature and air temperature. Sap-flow rates were found to be more prone to errors caused by heat storage effects under low flow conditions than at higher rates of sap flow. Furthermore, daytime fluctuations of air temperature and stem temperature inside the heat balance sensor were either in phase when a low, or in opposite phase when a high sap-flow rate was passing through the stem of the young tree. To investigate this relationship, we developed an experimental set-up with cut stem segments through which tap water could be pressed. This set-up allowed the effects of air temperature and sap-flow rates on stem temperatures within heat balance sensors to be clearly separated. Good mathematical relationships were obtained and were successfully used to assess the relative importance of air temperature and sap-flow rate with respect to the fluctuations in stem temperature of the young oak tree. Based on the established relationships, a novel approach was put forward to correct for errors introduced into sap-flow calculations caused by heat storage effects if no measured data on stem temperature are available.


2003 ◽  
Vol 83 (1) ◽  
pp. 31-38 ◽  
Author(s):  
S. V. Angadi ◽  
H. W. Cutforth ◽  
B. G. McConkey

Sap flow gauges using a heat balance have been reliable for measuring real-time transpiration in a number of crops. However, information on the accuracy of sap flow gauges in canola is lacking. Therefore, a study was conducted to validate the sap flow system in canola and to observe sap flow response to variations in temperature and solar radiation. There were strong relationships between sap flow measured with sap flow gauges and actual transpiration measured by the gravimetric method over short periods of 1 h (r2 = 0.93 and RMSE = 2.34 g h-1), and over longer periods of 1 d (r2 = 0.83 and RMSE = 48 g d-1), although sap flow slightly overestimated transpiration. In both cases the slope was not significantly different from 1. Water use in canola, estimated with sap flow gauges or from actual transpiration measurement, was dependent upon temperature (r2 = 0.94 to 0.96). Water use increased until daytime temperatures reached 36°C, after which water use decreased. Sap flow followed solar radiation trends in the field. Heat is lost or dissipated from the gauges convectively as the sap flows through the stem, conductively through the solid stem material, and radially into the surrounding air. As the convective proportion of the heat loss from the gauge increased, the accuracy of the water use estimation using the sap flow gauges increased. For sunny days, convective heat loss through sap flow accounted for a major portion of the total heat input to the gauges, while on cloudy days radial heat loss from the gauges accounted for a major portion of the heat input. Thus, at low sap flow rates during cloudy days, the possibility of error in the sap flow system was high. Overall, sap flow in canola was strongly related to daily solar radiation (r2 = 0.92). The sensitive response to weather variations and the possibility of improving the accuracy at high flow rates in the field makes the use of sap flow gauges a viable option for measuring real-time transpiration in canola. Key words: Brassica napus, canola, heat balance, sap flow, transpiration, temperature, solar radiation


1986 ◽  
Vol 18 (4-5) ◽  
pp. 53-61 ◽  
Author(s):  
P. B. Birch ◽  
G. G. Forbes ◽  
N. J. Schofield

Early results from monitoring runoff suggest that the programme to reduce application of superphosphate to farmlands in surrounding catchments has been successful in reducing input of phosphorus to the eutrophic Peel-Harvey estuary. In the estuary this phosphorus fertilizes algae which grow in abundance and accumulate and pollute once clean beaches. The success of the programme has been judged from application of an empirical statistical model, which was derived from 6 years of data from the Harvey Estuary catchment prior to a major change in fertilizer practices in 1984. The model relates concentration of phosphorus with rate of flow and time of year. High phosphorus concentrations were associated with high flow rates and with flows early in the high runoff season (May-July). The model predicted that the distribution of flows in 1984 should have resulted in a flow-weighted concentration of phosphorus near the long-term average; the observed concentration was 25% below the long-term average. This means that the amount of phosphorus discharged into the Harvey Estuary could have been about 2 5% less than expected from the volume of runoff which occurred. However several more years of data are required to confirm this trend.


1968 ◽  
Vol 108 (4) ◽  
pp. 641-646 ◽  
Author(s):  
A. Polson ◽  
W. Katz

1. The preparation of tanned gelatin spheres and granules from high-molecular-weight gelatin is described. This material is comparatively hard, giving high flow rates, is insoluble in water at temperatures between 0° and 100° and is resistant to digestion by trypsin and chymotrypsin. The high-molecular-weight fraction of gelatin was prepared by precipitation with polyethylene glycol, and the spheres and granules prepared from this fraction were hardened and insolubilized by tanning with either formalin or chromium salts or both. 2. The spheres and granules were used successfully for the separation of protein molecules and other protein-aceous materials ranging in molecular weight from 200 to greater than 6000000. This gel exclusion material has several properties superior to those of other products used for similar purposes. Further, it was noticed that the porosity of the spheres differed considerably from that of the granules.


2011 ◽  
Vol 39 (6) ◽  
pp. 1103-1110 ◽  
Author(s):  
J. E. Ritchie ◽  
A. B. Williams ◽  
C. Gerard ◽  
H. Hockey

In this study, we evaluated the performance of a humidified nasal high-flow system (Optiflow™, Fisher and Paykel Healthcare) by measuring delivered FiO2 and airway pressures. Oxygraphy, capnography and measurement of airway pressures were performed through a hypopharyngeal catheter in healthy volunteers receiving Optiflow™ humidified nasal high flow therapy at rest and with exercise. The study was conducted in a non-clinical experimental setting. Ten healthy volunteers completed the study after giving informed written consent. Participants received a delivered oxygen fraction of 0.60 with gas flow rates of 10, 20, 30, 40 and 50 l/minute in random order. FiO2, FEO2, FECO2 and airway pressures were measured. Calculation of FiO2 from FEO2 and FECO2 was later performed. Calculated FiO2 approached 0.60 as gas flow rates increased above 30 l/minute during nose breathing at rest. High peak inspiratory flow rates with exercise were associated with increased air entrainment. Hypopharyngeal pressure increased with increasing delivered gas flow rate. At 50 l/minute the system delivered a mean airway pressure of up to 7.1 cmH2O. We believe that the high gas flow rates delivered by this system enable an accurate inspired oxygen fraction to be delivered. The positive mean airway pressure created by the high flow increases the efficacy of this system and may serve as a bridge to formal positive pressure systems.


Author(s):  
Mehmed Rafet O¨zdemir ◽  
Ali Kos¸ar ◽  
Orc¸un Demir ◽  
Cemre O¨zenel ◽  
Og˘uzhan Bahc¸ivan

Recently, micro/nanofabrication technology has been used to develop a number of microfluidic systems. With its integration to microfluidic devices, microchannels and micro scale pin fin heat sinks find applications in many areas such as drug delivery and propulsion in biochemical reaction chambers and micro mixing. Many research efforts have been performed to reveal thermal and hydrodynamic performances of microchannel based micro fluidic devices. In the current study, it is aimed to extend the knowledge on this field by investigating heat and fluid flow in micro heat sinks at high flow rates. Moreover, thermodynamic and thermo-economic aspects were also considered. De-ionized water was used as the coolant in the system. Flow rates were measured over pressures of 20–80 psi. A serpentine heater was deposited at the back of the micro pin fin devices to enable the delivery of heat to these devices. Two micro-pin fin devices each having different geometrical properties (Circular based and Hydrofoil based) were used in this study. In addition, the performances (thermal-hydraulic, exergy, exergo-economic) were also experimentally obtained for a plain microchannel device. Thermal resistances, exergy efficiencies and thermo-economic parameters were obtained from the devices and their performances were assessed.


2017 ◽  
Vol 109 (3) ◽  
pp. 1122-1128 ◽  
Author(s):  
Yueyue Wang ◽  
Xiao Zhang ◽  
Xinhua Xiao ◽  
Joshua Heitman ◽  
Robert Horton ◽  
...  

2019 ◽  
Vol 36 (4) ◽  
pp. 401-410 ◽  
Author(s):  
Xiao-Qi Jia ◽  
Bao-Ling Cui ◽  
Zu-Chao Zhu ◽  
Yu-Liang Zhang

Abstract Affected by rotor–stator interaction and unstable inner flow, asymmetric pressure distributions and pressure fluctuations cannot be avoided in centrifugal pumps. To study the pressure distributions on volute and front casing walls, dynamic pressure tests are carried out on a centrifugal pump. Frequency spectrum analysis of pressure fluctuation is presented based on Fast Fourier transform and steady pressure distribution is obtained based on time-average method. The results show that amplitudes of pressure fluctuation and blade-passing frequency are sensitive to the flow rate. At low flow rates, high-pressure region and large pressure gradients near the volute tongue are observed, and the main factors contributing to the pressure fluctuation are fluctuations in blade-passing frequency and high-frequency fluctuations. By contrast, at high flow rates, fluctuations of rotating-frequency and low frequencies are the main contributors to pressure fluctuation. Moreover, at low flow rates, pressure near volute tongue increases rapidly at first and thereafter increases slowly, whereas at high flow rates, pressure decreases sharply. Asymmetries are observed in the pressure distributions on both volute and front casing walls. With increasing of flow rate, both asymmetries in the pressure distributions and magnitude of the pressure decrease.


Sign in / Sign up

Export Citation Format

Share Document