Thermal Hydraulic, Exergy and Exergy-Economic Analysis of Micro Heat Sinks at High Flow Rates

Author(s):  
Mehmed Rafet O¨zdemir ◽  
Ali Kos¸ar ◽  
Orc¸un Demir ◽  
Cemre O¨zenel ◽  
Og˘uzhan Bahc¸ivan

Recently, micro/nanofabrication technology has been used to develop a number of microfluidic systems. With its integration to microfluidic devices, microchannels and micro scale pin fin heat sinks find applications in many areas such as drug delivery and propulsion in biochemical reaction chambers and micro mixing. Many research efforts have been performed to reveal thermal and hydrodynamic performances of microchannel based micro fluidic devices. In the current study, it is aimed to extend the knowledge on this field by investigating heat and fluid flow in micro heat sinks at high flow rates. Moreover, thermodynamic and thermo-economic aspects were also considered. De-ionized water was used as the coolant in the system. Flow rates were measured over pressures of 20–80 psi. A serpentine heater was deposited at the back of the micro pin fin devices to enable the delivery of heat to these devices. Two micro-pin fin devices each having different geometrical properties (Circular based and Hydrofoil based) were used in this study. In addition, the performances (thermal-hydraulic, exergy, exergo-economic) were also experimentally obtained for a plain microchannel device. Thermal resistances, exergy efficiencies and thermo-economic parameters were obtained from the devices and their performances were assessed.

Author(s):  
Ildar F. Akhmadullin ◽  
Randall D. Manteufel ◽  
Christopher Greene

Experimental measurements are reported for high-flow liquid-cooled heat sinks designed for cooling electronics components such as a CPU. The flow rate is up to 2 GPM with internal flow passage length scales on the order of 0.1 to 1.0 mm in the primary heat transfer region. Of the designs tested, three achieved maximum flow rates with pressure drops of less than 1.5 psi. Two have lower maximum flow rates because of higher internal flow resistance. In the experiments, particular attention is given to sources of experimental uncertainty and the propagation of uncertainty through the calculations to reported thermal resistance, R (°C/W). Analysis includes bias and precision errors for direct measurement of temperature, flow rate, and pressure drop. Additionally, a separate thermocouple calibration test is reported to establish measurement uncertainties for the system. Main emphasis is made to the error propagation in thermal resistance calculations of each heat sink and measurement of heat removal rate from the CPU. Data is used to determine the standard error for R which ranges up to about 0.05 °C/W with the maximum for one heat sink up to 0.07 °C/W. Averaging of repeated measurements at the same flow rate without accounting for the range of the original data will result in lower uncertainties in the reported results.


Author(s):  
T. J. John ◽  
B. Mathew ◽  
H. Hegab

The need for dissipating heat from microsystems has increased drastically in the last decade. Several methods of heat dissipation using air and liquids have been proposed by many studies, and pin-fin micro heat sinks are one among them. Researchers have developed several effective pin-fin structures for use in heat sinks, but not much effort has been taken towards the optimization of profile and dimensions of the pin-fin. In this paper the authors studied the effect of different pin-fin shapes on the thermal resistance and pressure drop in a specific micro heat-sink. Optimization subjected to two different constraints is studied in this paper. The first optimization is subjected to constant flow rate and the second one is subjected to constant pressure drop. Both optimization processes are carried out using computer simulations generated using COVENTORWARE™. Two of the best structures from each of these optimization studies are selected and further analysis is performed for optimizing their structure dimensions such as width, height and length. A section of the total micro heat-sink is modeled for the initial optimization of the pin-fin shape. The model consists of two sections, the substrate and the fluid. Six different shapes: square, circle, rectangle, triangle, oval and rhombus were analyzed in the initial optimization study. Preliminary tests were conducted using the first model described above for a flow rate of 0.6ml/min. The non dimensional overall thermal resistance of the heat sink, and the nondimensional pumping power was calculated from the results. A figure of merit (FOM) was developed using the nondimensional thermal resistance and nondimensional pumping power for each structure with different pin-fin shapes. Smaller the value of FOM better the performance of the heat sink. The study revealed that the circle and ellipse structures have the best performance and the rectangle structure had the worst performance at low flow rates. At high flow rates rectangular and square structures have the best performance.


1986 ◽  
Vol 18 (4-5) ◽  
pp. 53-61 ◽  
Author(s):  
P. B. Birch ◽  
G. G. Forbes ◽  
N. J. Schofield

Early results from monitoring runoff suggest that the programme to reduce application of superphosphate to farmlands in surrounding catchments has been successful in reducing input of phosphorus to the eutrophic Peel-Harvey estuary. In the estuary this phosphorus fertilizes algae which grow in abundance and accumulate and pollute once clean beaches. The success of the programme has been judged from application of an empirical statistical model, which was derived from 6 years of data from the Harvey Estuary catchment prior to a major change in fertilizer practices in 1984. The model relates concentration of phosphorus with rate of flow and time of year. High phosphorus concentrations were associated with high flow rates and with flows early in the high runoff season (May-July). The model predicted that the distribution of flows in 1984 should have resulted in a flow-weighted concentration of phosphorus near the long-term average; the observed concentration was 25% below the long-term average. This means that the amount of phosphorus discharged into the Harvey Estuary could have been about 2 5% less than expected from the volume of runoff which occurred. However several more years of data are required to confirm this trend.


1968 ◽  
Vol 108 (4) ◽  
pp. 641-646 ◽  
Author(s):  
A. Polson ◽  
W. Katz

1. The preparation of tanned gelatin spheres and granules from high-molecular-weight gelatin is described. This material is comparatively hard, giving high flow rates, is insoluble in water at temperatures between 0° and 100° and is resistant to digestion by trypsin and chymotrypsin. The high-molecular-weight fraction of gelatin was prepared by precipitation with polyethylene glycol, and the spheres and granules prepared from this fraction were hardened and insolubilized by tanning with either formalin or chromium salts or both. 2. The spheres and granules were used successfully for the separation of protein molecules and other protein-aceous materials ranging in molecular weight from 200 to greater than 6000000. This gel exclusion material has several properties superior to those of other products used for similar purposes. Further, it was noticed that the porosity of the spheres differed considerably from that of the granules.


2011 ◽  
Vol 39 (6) ◽  
pp. 1103-1110 ◽  
Author(s):  
J. E. Ritchie ◽  
A. B. Williams ◽  
C. Gerard ◽  
H. Hockey

In this study, we evaluated the performance of a humidified nasal high-flow system (Optiflow™, Fisher and Paykel Healthcare) by measuring delivered FiO2 and airway pressures. Oxygraphy, capnography and measurement of airway pressures were performed through a hypopharyngeal catheter in healthy volunteers receiving Optiflow™ humidified nasal high flow therapy at rest and with exercise. The study was conducted in a non-clinical experimental setting. Ten healthy volunteers completed the study after giving informed written consent. Participants received a delivered oxygen fraction of 0.60 with gas flow rates of 10, 20, 30, 40 and 50 l/minute in random order. FiO2, FEO2, FECO2 and airway pressures were measured. Calculation of FiO2 from FEO2 and FECO2 was later performed. Calculated FiO2 approached 0.60 as gas flow rates increased above 30 l/minute during nose breathing at rest. High peak inspiratory flow rates with exercise were associated with increased air entrainment. Hypopharyngeal pressure increased with increasing delivered gas flow rate. At 50 l/minute the system delivered a mean airway pressure of up to 7.1 cmH2O. We believe that the high gas flow rates delivered by this system enable an accurate inspired oxygen fraction to be delivered. The positive mean airway pressure created by the high flow increases the efficacy of this system and may serve as a bridge to formal positive pressure systems.


Sign in / Sign up

Export Citation Format

Share Document