A Practical Approach to Energy Optimization Using Pinch Analysis: A Case Study of an Oil Refinery

2021 ◽  
Author(s):  
Paschal Uzoma Ndunagu ◽  
Emeka Emmanuel Alaike ◽  
Theophile Megueptchie

Abstract The objective of this paper is to perform an energy optimization study using pinch analysis on the Heat Exchanger Network (HEN) of a Crude Distillation Unit to maximum heat recovery, minimize energy consumption and increase refining margin. The heat exchanger network (HEN) considered comprises exchangers from the pre-heat section of the atmospheric distillation unit, which recovers heat from the product streams to incrementally heat the crude oil feed stream before entering the furnace. This paper illustrates how to perform a detailed HEN retrofitting study using an established design method known as Pinch Analysis to reduce the operating cost by increasing energy savings of the HEN of an existing complex refinery of moderate capacity. Analysis and optimization were carried out on the HEN of the CDU consist a total of 19 heat exchangers which include: process to process (P2P) heat exchangers, heaters and coolers. In the analysis, different feasible retrofit scenarios were generated using the pinch analysis approach. The retrofit designs included the addition of new heat exchangers, rearrangement of heat exchanger (re-sequencing) and re-piping of existing exchangers. Aspen Hysys V9 was used to simulate the CDU and Aspen Energy Analyser was used to perform pinch analysis on the HEN of the pre-heat train. Several retrofit scenarios were generated, the optimum retrofit solution was a trade-off between the capital cost of increasing heat exchanger surface area, payback time, energy / operating cost savings of hot and cold utilities. Results indicated that by rearrangement (Re-sequencing), the pre-heat train can reduce hot (fired heat) and cold (air and cooling water) utilities consumption to improve energy savings by 8% which includes savings on fired heat of about 4.6 MW for a payback period of 2 years on capital investment. The results generated were based on a ΔTmin of 10°C and pinch temperature of 46.3°C. Initial sensitivity analysis on the ΔTmin indicated that variation of total cost index is quite sensitive and increases with increase in ΔTmin at the temperature range of 14.5-30°C, however total cost index remains constant and minimal at a temperature range between 10°C-14.5°C for the CDU preheat train under study. In addition, the implementation of the optimum retrofit result is straightforward and feasible with minimum changes to the existing base case/design.

2004 ◽  
Vol 69 (10) ◽  
pp. 827-837 ◽  
Author(s):  
Mirjana Kijevcanin ◽  
Bojan Djordjevic ◽  
Ozren Ocic ◽  
Mladen Crnomarkovic ◽  
Maja Maric ◽  
...  

A heat exchanger network (HEN) for the process of methanol synthesis has been studied by pinch design analysis. Great economic and energy savings were realized by the pinch analysis in comparison to the existing plant. Also, it was found that it is possible to reduce the requirements for the consumption of utilities. The HEN was reconstruded by adding new heat exchangers. In order to produce new HEN, the capital costs had to be increased, but the total cost trade-off between the capital and energy costs will be decrease by 30 %.


Energies ◽  
2020 ◽  
Vol 13 (10) ◽  
pp. 2656 ◽  
Author(s):  
Bohong Wang ◽  
Jiří Jaromír Klemeš ◽  
Petar Sabev Varbanov ◽  
Min Zeng

Heat exchanger network (HEN) retrofit is a vital task in the process design to improve energy savings. Various types of heat exchangers such as shell and tube, double-pipe, compact plate, and spiral tube have their working temperature ranges and costs. Selecting suitable types of heat exchangers according to their temperature ranges and costs is a crucial aspect of industrial implementation. However, considering the type of heat exchangers in the HEN retrofit process is rarely seen in previous publications. This issue can be solved by the proposed Shifted Retrofit Thermodynamic Grid Diagram with the Shifted Temperature Range of Heat Exchangers (SRTGD-STR). The temperature ranges of six widely used heat exchanger types are coupled in the grid diagram. This diagram enables the visualisation of identifying the potential retrofit plan of HEN with heat-exchanger type selection. The retrofit design aims to minimise utility cost and capital cost. An illustrative example and a case study are presented to show the effectiveness of the method.


2012 ◽  
Author(s):  
Sharifah Rafidah Wan Alwi ◽  
Muhammad Azan Tamar Jaya ◽  
Zainuddin Abdul Manan

Kilang penapisan minyak sawit lazimnya melibatkan proses penggunaan tenaga yang tinggi. Peningkatan kecekapan tenaga adalah amat penting bagi memastikan keuntungan tercapai. Kertas kerja ini menggunakan teknik analisis jepit bagi memaksimumkan penggunaan semula haba dan meningkatkan kecekapan sistem rangkaian haba sedia ada di kilang penghasilan minyak sawit, tertakluk kepada kekangan–kekangan proses. Langkah–langkah yang terlibat ialah penetapan sasaran guna semula haba maksimum diikuti dengan reka bentuk rangkaian haba yang ekonomik. Aplikasi teknik berkenaan kepada kilang penghasilan minyak sawit telah menghasilkan pengurangan penggunaan haba panas dan sejuk sebanyak 700 kW (21%), atau penjimatan kos utiliti sebanyak RM370,787, dengan pelaburan kapital sebanyak RM656,293 dan jangka pulangan balik selama 1.77 tahun. Kata kunci: Analisis jepit; minyak kelapa sawit; sedia ada; rangkaian pemindahan haba; kitar semula haba maksimum A palm oil refinery involves energy–intensive processes. Maximizing thermal efficiency of palm oil refinery is crucial for the plant profitability. This work implements a pinch analysis retrofit technique to maximize heat recovery and thermal efficiency of a palm oil refinery, subject to the existing process constraints. The procedures involve setting the maximum heat recovery targets and cost–effective retrofit of the heat exchanger network (HEN). Application of the technique on a palm oil refinery results in reduction of 700 kW (21%) heating and cooling loads or a saving of RM370,787, incurring a capital investment of about RM656,293 and a payback period of 1.77 years. Key words: Pinch analysis; palm oil; retrofit; heat exchanger network; maximum heat recovery


Author(s):  
Suneel Nagar ◽  
Ajay Singh ◽  
Deepak Patel

The objective of this study is to provide modern analytical and empirical tools for evaluation of the thermal-flow performance or design of air-cooled heat exchangers (ACHE) and cooling towers. This review consist various factors which effect the performance of ACHE. We introduced systematically to the literature, theory, and practice relevant to the performance evaluation and design of industrial cooling. Its provide better understanding of the performance characteristics of a heat exchanger, effectiveness can be improved in different operating conditions .The total cost of cycle can be reduced by increasing the effectiveness of heat exchanger.


2019 ◽  
Author(s):  
Totok Ruki Biyanto ◽  
Nanda E. Tama ◽  
Inesya Permatasari ◽  
Muhammad G. Sabillah ◽  
David H. Napitupulu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document