scholarly journals The Novel biocatalytic cascade ZIF-8 capsule/Polysulfone Stereostructure and its Application in Amperometric Glucose Biosensors

Author(s):  
Cang Wang ◽  
Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3757
Author(s):  
Gabriela Valdés-Ramírez ◽  
Laura Galicia

A biosensing membrane base on ferulic acid and glucose oxidase is synthesized onto a carbon paste electrode by electropolymerization via cyclic voltammetry in aqueous media at neutral pH at a single step. The developed biosensors exhibit a linear response from 0.082 to 34 mM glucose concentration, with a coefficient of determination R2 equal to 0.997. The biosensors display a sensitivity of 1.1 μAmM−1 cm−2, a detection limit of 0.025 mM, and 0.082 mM as glucose quantification limit. The studies reveal stable, repeatable, and reproducible biosensors response. The results indicate that the novel poly-ferulic acid membrane synthesized by electropolymerization is a promising method for glucose oxidase immobilization towards the development of glucose biosensors. The developed glucose biosensors exhibit a broader linear glucose response than other polymer-based glucose biosensors.


2000 ◽  
Vol 33 (9) ◽  
pp. 1733-1753 ◽  
Author(s):  
Pascal Mailley ◽  
Serge Cosnier ◽  
Liliance Coche-Guérente

2018 ◽  
Vol 5 (5) ◽  
pp. 055031 ◽  
Author(s):  
Mayoorika Shukla ◽  
Pramila ◽  
Jitesh Agrawal ◽  
Tejendra Dixit ◽  
I A Palani ◽  
...  

Biosensors ◽  
2019 ◽  
Vol 9 (2) ◽  
pp. 50 ◽  
Author(s):  
Hao-Chun Chiang ◽  
Yanyan Wang ◽  
Qi Zhang ◽  
Kalle Levon

A highly sensitive electrochemical biosensor with a signal amplification platform of electrodeposited gold nanoparticle (AuNP) has been developed and characterized. The sizes of the synthesized AuNP were found to be critical for the performance of biosensor in which the sizes were dependent on HAuCl4 and acid concentrations; as well as on scan cycles and scan rates in the gold electro-reduction step. Systematic investigations of the adsorption of proteins with different sizes from aqueous electrolyte solution onto the electrodeposited AuNP surface were performed with a potentiometric method and calibrated by design of experiment (DOE). The resulting amperometric glucose biosensors was demonstrated to have a low detection limit (> 50 μM) and a wide linear range after optimization with AuNP electrodeposition.


2019 ◽  
Vol 21 (6) ◽  
pp. 2968-2976 ◽  
Author(s):  
Gintautas Bagdžiūnas ◽  
Arūnas Ramanavičius

We have evaluated charge transfer between enzyme glucose oxidase (GOx) and organic semiconductors, both of which were applied in the design of amperometric glucose biosensors.


2004 ◽  
Vol 25 (1) ◽  
pp. 348-354 ◽  
Author(s):  
Sabine Reiter ◽  
Dirk Ruhlig ◽  
Bertrand Ngounou ◽  
Sebastian Neugebauer ◽  
Sandra Janiak ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document