scholarly journals Thermal Environment Optimization and Energy Saving of Residential Buildings under the Demand of Low-Carbon Operation

2021 ◽  
Vol 39 (2) ◽  
pp. 659-668
Author(s):  
Lirong Ding ◽  
Chun Chen
2017 ◽  
Vol 05 (04) ◽  
pp. 1750022
Author(s):  
Wei JIANG ◽  
Xuhui ZHANG

Despite China's significant progress in energy saving renovations, during the past 10 years, problems about inefficiencies remain. In the Netherlands, the energy labeling system (ELS) effectively linked policy objectives and market forces, combined with the stepped tariffs aimed at the performance of energy-saving renovation, generating a virtuous cycle of housing energy efficiency upgrading. China may draw the experience from Netherlands. In this regard, the authors probe the market effect and operating mechanism of the Dutch ELS and the stepped tariffs. The theory of multi-level governance (MLG) is introduced to the filed investigations both in China and the Netherlands. Based on the group-interviews and depth-interviews with the officials in related agencies and the residents of retrofitting housing, the authors obtained first-hand information to ensure a close case study on Netherlands' housing ELS and its implementation, in order to provide some enlightenment for China's existing housing renovation and low carbon development.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2011 ◽  
Vol 280 ◽  
pp. 147-151 ◽  
Author(s):  
Hong Guo ◽  
Min Fang Su ◽  
Xiao Jun Jin

Based on the current energy consumption situation of existing masonry-concrete residential buildings in China, it discussed the main energy-saving renovation policies and technologies. Taking existing masonry-concrete residential building of Taiyuan city as a case, it analyzed its heat loss situations, energy-saving renovation design and reconstruction technologies of building envelope. It discussed energy-saving renovation effects. Energy efficiency and indoor thermal environment improved significantly after energy-saving renovation. The building life is extended.


2019 ◽  
Vol 11 (17) ◽  
pp. 4540 ◽  
Author(s):  
Haiyan Duan ◽  
Shipei Zhang ◽  
Siying Duan ◽  
Weicheng Zhang ◽  
Zhiyuan Duan ◽  
...  

The building sector has gradually become a major contributor of carbon emissions in recent years. Its carbon emissions, which result from the long heating period and considerable consumption of coal in residential buildings during operation, must be reduced. To this end, the long-range energy alternatives planning system was adopted for the forecasting of carbon emissions in baseline scenarios, energy-saving, energy-saving–low-carbon, and low-carbon. On the basis of these predictions, the contributions of heating, cooling, cooking, illumination, washing, and other activities to carbon emissions were analyzed. The influencing factors in the reduction of carbon emissions from residential buildings in a cold region were identified. The results showed that energy-saving–low-carbon was the optimal scenario to reduce carbon emissions. Meanwhile, carbon emissions will peak in 2030, with a value of 42.06 Mt under the same scenario. As the top three influencing factors, heating, cooling, and cooking contribute 55.74%, 18.86%, and 17.29% of carbon emissions, respectively. Sensitivity results showed the differential effects of 32 factors on the reduction of carbon emissions in residential buildings. Carbon emissions could be reduced by 17.41%, 35.51%, 31.10%, and 14.10% by controlling the building scale, heating, cooling, and cooking, respectively. To this end, seven factors, including the rationing of central heating, were identified. Then, pathways to reducing carbon emissions were proposed under different scenarios. The present research fills the gap between reality and the predicted pathway, considering the heterogeneity of the climate.


2020 ◽  
Vol 2020 ◽  
pp. 1-16
Author(s):  
Qin Zhao ◽  
Xiaona Fan ◽  
Qing Wang ◽  
Guochen Sang ◽  
Yiyun Zhu

How to create a healthy and comfortable indoor environment without causing a substantial increase in energy consumption has become a strategic problem that the development of all countries must face and solve. According to the climatic conditions of Qinba Mountains in China, combined with the characteristics of local rural residential buildings and residents’ living habits, the field survey and theoretical analysis were used to study the thermal environment status and the heating energy consumption condition of local rural residential buildings. The thermal design method of walls for the local rural energy-saving buildings based on the indoor uniform radiation field was explored by using the outdoor comprehensive temperature function expressed by the fourth-order harmonic Fourier series as the boundary condition of the wall thermal analysis. ANSYS CFX was adopted to study the suitability of the energy-saving wall structure designed by the above method. The results show that the indoor thermal environment of local rural residential buildings in winter is not ideal and the heating energy consumption is high, but this area has the geographical advantage to develop solar energy buildings. It is proposed that the indoor thermal comfort temperature of local rural residential buildings in winter should not be lower than 14°C. When the internal surface temperature of the external walls in different orientations are equally based on the design principle of uniform radiation field, the heat transfer coefficient of the east wall, the west wall, and the north wall of the local rural residential buildings is 1.13 times, 1.06 times, and 1.14 times of the south wall heat transfer coefficient, respectively. The energy-saving structural wall with KPI porous brick as the main material and the south wall heat transfer coefficient of 0.9 W/(m2·K) is the most suitable energy-saving wall for local rural residential buildings.


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2013 ◽  
Vol 409-410 ◽  
pp. 526-530
Author(s):  
Min Fang Su ◽  
Hong Guo

Based on the structure feature and energy consumption situation of high-rise reinforced concrete residential buildings which built in end of last century, it discussed the main energy-saving renovation technologies and methods. Demonstrating high-rise reinforced concrete residential building of Taiyuan as a case, it analyzed its heat loss problems and defects of original design. Energy-saving renovation plan proposed and put reconstruction technologies of building envelope and heating system in practice. It discusses energy-saving renovation effects, energy efficiency. Indoor thermal environment improved significantly after energy-saving renovation on building envelope and heat system.


2006 ◽  
Vol 38 (11) ◽  
pp. 1308-1319 ◽  
Author(s):  
Hiroshi Yoshino ◽  
Yasuko Yoshino ◽  
Qingyuan Zhang ◽  
Akashi Mochida ◽  
Nianping Li ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (5) ◽  
pp. 1321
Author(s):  
Yu-Jin Hwang ◽  
Jae-Weon Jeong

The objective of this research is to establish an appropriate operating strategy for a radiant floor heating system that additionally has an air source heat pump for providing convective air heating separately, leading to heating energy saving and thermal comfort in residential buildings. To determine the appropriate optimal operating ratio of each system taking charge of combined heating systems, the energy consumption of the entire system was drawn, and the adaptive floor surface temperature was reviewed based on international standards and literature on thermal comfort. For processing heating loads with radiant floor heating and air source heating systems, the heating capacity of radiant floor heating by 1 °C variation in floor temperature was calculated, and the remaining heating load was handled by the heating capacity of the convective air heating heat pump. Consequently, when the floor temperature was 25 °C, all heating loads were removed by radiant floor heating only. When handling all heating loads with the heat pump, 59.2% less energy was used compared with radiant floor heating only. Considering the local discomfort of the soles of the feet, the floor temperature is expected to be suitable at 22–23 °C, and 31.5–37.6% energy saving compared with those of radiant floor heating alone were confirmed.


Sign in / Sign up

Export Citation Format

Share Document