Indoor thermal environment and energy saving for urban residential buildings in China

2006 ◽  
Vol 38 (11) ◽  
pp. 1308-1319 ◽  
Author(s):  
Hiroshi Yoshino ◽  
Yasuko Yoshino ◽  
Qingyuan Zhang ◽  
Akashi Mochida ◽  
Nianping Li ◽  
...  
2011 ◽  
Vol 280 ◽  
pp. 147-151 ◽  
Author(s):  
Hong Guo ◽  
Min Fang Su ◽  
Xiao Jun Jin

Based on the current energy consumption situation of existing masonry-concrete residential buildings in China, it discussed the main energy-saving renovation policies and technologies. Taking existing masonry-concrete residential building of Taiyuan city as a case, it analyzed its heat loss situations, energy-saving renovation design and reconstruction technologies of building envelope. It discussed energy-saving renovation effects. Energy efficiency and indoor thermal environment improved significantly after energy-saving renovation. The building life is extended.


Energies ◽  
2021 ◽  
Vol 14 (10) ◽  
pp. 2776
Author(s):  
Xin Ye ◽  
Jun Lu ◽  
Tao Zhang ◽  
Yupeng Wang ◽  
Hiroatsu Fukuda

Space cooling is currently the fastest-growing end-user in buildings. The global warming trend combined with increased population and economic development will lead to accelerated growth in space cooling in the future, especially in China. The hot summer and cold winter (HSCW) zone is the most densely populated and economically developed region in China, but with the worst indoor thermal environment. Relatively few studies have been conducted on the actual measurements in the optimization of insulation design under typical intermittent cooling modes in this region. This case study was conducted in Chengdu—the two residences selected were identical in design, but the south bedroom of the case study residence had interior insulation (inside insulation on all opaque interior surfaces of a space) retrofitted in the bedroom area in 2017. In August 2019, a comparative on-site measurement was done to investigate the effect of the retrofit work under three typical intermittent cooling patterns in the real-life scenario. The experimental result shows that interior insulation provides a significant improvement in energy-saving and the indoor thermal environment. The average energy savings in daily cooling energy consumption of the south bedroom is 42.09%, with the maximum reaching 48.91%. In the bedroom with interior insulation retrofit, the indoor temperature is closer to the set temperature and the vertical temperature difference is smaller during the cooling period; when the air conditioner is off, the room remains a comfortable temperature for a slightly longer time.


2012 ◽  
Vol 476-478 ◽  
pp. 1589-1595
Author(s):  
Yi Ping Zhu ◽  
Xi Liao ◽  
Shu Yun Wu ◽  
Jing Luo ◽  
Yuan Jiang ◽  
...  

Based on indoor thermal environment test and questionnaire surveys, the paper studies on thermal insulation capacity and indoor thermal environment of the vernacular dwellings in Wei-he Plain of Shaanxi Province, China, and analyses their heating methods and application status. Besides, the popularity of sustainable techniques in local area has been evaluated and summarized. Moreover, the paper discusses the present problems in local indoor thermal environment and energy-saving status.


2014 ◽  
Vol 10 (1) ◽  
pp. 172-183 ◽  
Author(s):  
Sushil B. Bajracharya

This paper seeks to investigate into the aspects of thermal performance of traditional residential buildings in traditional settlements of Kathmandu valley. This study proceeds to analyze the detailed field data collected, with a view to identify the indoor thermal environment with respect to outdoor thermal environment in different seasons. This paper also compares the thermal performance of traditional buildings with modern residential buildings of traditional settlements of the valley. There is a regression analysis to obtain information about the thermal environment of different traditional and modern residential buildings with different conditions. The paper concludes that, thermal performance of traditional residential building, adapted in various ways to the changing thermal regime for thermal comfort is better than that of contemporary buildings.DOI: http://dx.doi.org/10.3126/jie.v10i1.10898Journal of the Institute of Engineering, Vol. 10, No. 1, 2014,  pp. 172–183


2021 ◽  
Author(s):  
Christopher L. K. Wang

As sleep is unconscious, the traditional definition of thermal comfort with conscious judgment does not apply. In this thesis sleep thermal comfort is defined as the thermal condition which enables sleep to most efficiently rejuvenate the body and mind. A comfort model was developed to stimulate the respective thermal environment required to achieve the desired body thermal conditions and a new infrared sphere method was developed to measure mean radiant temperature. Existing heating conditions according to building code conditions during sleeping hours was calculated to likely overheat a sleeping person and allowed energy saving potential by reducing nighttime heating set points. Experimenting with existing radiantly and forced air heated residential buildings, it was confirmed that thermal environment was too hot for comfortable sleep and that the infrared sphere method shows promise. With the site data, potential energy savings were calculated and around 10% of energy consumption reduction may be achieved during peak heating.


2020 ◽  
Vol 15 (3) ◽  
pp. 163-170
Author(s):  
Rajan KC ◽  
Hom Bahadur Rijal ◽  
Masanori Shukuya ◽  
Kazui Yoshida

The energy use in residential dwellings has been increasing due to increasing use of modern electric appliances to make the lifestyle easier, entertaining and better. One of the major purposes of indoor energy use is for improving indoor thermal environment for adjusting thermal comfort. Along with the use of passive means like the use of mechanical devices, the occupants in any dwellings use active means such as the use of natural ventilation, window opening, and clothing adjustment. In fact, the use of active means when the outdoor environment is good enough might be more suitable to improve indoor thermal environment than the use of mechanical air conditioning units, which necessarily require electricity. Therefore, the people in developing countries like Nepal need to understand to what extent the occupants can use active means to manage their own indoor thermal comfort. The use of active means during good outdoor environment might be an effective way to manage increasing energy demand in the future. We have made a field survey on the occupants’ adaptive behaviors for thermal comfort in a Japanese condominium equipped with Home Energy Management System (HEMS). Online questionnaire survey was conducted in a condominium with 356 families from November 2015 to October 2016 to understand the occupants’ behaviors. The number of 17036 votes from 39 families was collected. The indoor air temperature, relative humidity and illuminance were measured at the interval of 2-10 minutes to know indoor thermal environmental conditions. The occupants were found using different active behaviors for thermal comfort adjustments even in rather harsh summer and winter. Around 80% of the occupants surveyed opened windows when the outdoor air temperature was 30⁰C in free running (FR) mode and the clothing insulation was 0.93 clo when the outdoor air temperature was 0⁰C. The result showed that the use of mechanical heating and cooling was not necessarily the first priority to improve indoor thermal environment. Our result along with other results in residential buildings showed that the adaptive behaviors of the occupants are one of the primary ways to adjust indoor thermal comfort. This fact is important in enhancing the energy saving building design.


2014 ◽  
Vol 18 (3) ◽  
pp. 889-902 ◽  
Author(s):  
Manoj Singh ◽  
Sadhan Mahapatra ◽  
Jacques Teller

Indoor thermal environment monitoring has been done in 20 residential buildings of Liege city followed by questionnaire based comfort survey amongst the occupants of 85 houses in order to record their preference and expectations about indoor thermal environment in winter and spring season. It is found from the analysis that change of glazing has a minimum or even sometimes an adverse effect on the existing indoor environment due to the absence of proper insulation of the rest of the building envelope. It is observed that in winter there is a sudden drop in indoor temperature and also overheating in summer. This is due to unplanned installation of glazing which actually increases the fenestration area ratio leading to higher indoor temperature fluctuation and causes discomfort. It is also important that the occupant?s preference and expectations as well as overall assessment of indoor environment needs to be consider towards energy efficiency improvement.


Sign in / Sign up

Export Citation Format

Share Document