Alternative technique for analyzing instrumented indentation data

2001 ◽  
Vol 16 (11) ◽  
pp. 3202-3206 ◽  
Author(s):  
W. C. Oliver

A new analysis technique for calculating the hardness, modulus, and contact area from indentation data obtained using pyramidal or conical indenters was formulated and compared with another commonly used technique. Experimental data using a Berkovich indenter to indent fused silica and tungsten were examined. In addition, finite element modeling results were used to examine the effectiveness of the analytical techniques when a wide range of materials properties was considered. The new technique relies on the slope of the loading curve rather than the indenter displacement as an input. It is shown that the new technique is far less affected by the deviation of the geometry of the indenter from its intended shape. This effect removes the necessity to have detailed descriptions of the precise tip geometry in some cases. The new technique does not reduce errors associated with pile up of material near the indenter.

Separations ◽  
2021 ◽  
Vol 8 (12) ◽  
pp. 228
Author(s):  
Dhananjay I. Patel ◽  
Tuhin Roychowdhury ◽  
Collin Jacobsen ◽  
Colton Myers ◽  
Jason S. Herrington ◽  
...  

We report the first fabrication of sputtered carbon, solid-phase microextraction (SPME) fibers. These fibers have competitive extraction capabilities compared with the commercial carbon wide range (CWR) SPME fiber. This report also includes a demonstration of a newly developed SPME test mix that includes 15 different compounds with a wide range of functional groups and chemical properties. The fiber fabrication process involves sputtering carbon onto fused silica fibers, and the effects of throw distance on the morphology of the carbon coatings were studied. Four different carbon coating thicknesses were evaluated, with PDMS added as a stationary phase. These fibers were characterized with multiple analytical techniques, including scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), water contact angle (WCA) goniometry, as well as headspace (HS) and direct immersion (DI)–SPME–GC–MS. The best (11.5 µm) sputtered carbon SPME fibers, with and without PDMS, were evaluated using the new evaluation mix and compared with the commercial CWR fiber and a previously sputtered/developed silicon fiber. The new probe mix helped elucidate differences among the fibers, which would have been missed by current commercial test mixes. The sputtered carbon SPME fibers showed similar functional group selectivity as commercial CWR fibers. However, the sputtered carbon fibers showed higher responses per volume compared with the commercial CWR fiber, indicating the porous morphology of the sputtered carbon has the ability to overcome large phase thickness/volume discrepancies and increase the relative recovery for various compounds.


Author(s):  
R.W. Horne

The technique of surrounding virus particles with a neutralised electron dense stain was described at the Fourth International Congress on Electron Microscopy, Berlin 1958 (see Home & Brenner, 1960, p. 625). For many years the negative staining technique in one form or another, has been applied to a wide range of biological materials. However, the full potential of the method has only recently been explored following the development and applications of optical diffraction and computer image analytical techniques to electron micrographs (cf. De Hosier & Klug, 1968; Markham 1968; Crowther et al., 1970; Home & Markham, 1973; Klug & Berger, 1974; Crowther & Klug, 1975). These image processing procedures have allowed a more precise and quantitative approach to be made concerning the interpretation, measurement and reconstruction of repeating features in certain biological systems.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Julien Salvadori ◽  
Freddy Odille ◽  
Gilles Karcher ◽  
Pierre-Yves Marie ◽  
Laetitia Imbert

Abstract Purpose Digital PET involving silicon photomultipliers (SiPM) provides an enhanced time-of-flight (TOF) resolution as compared with photomultiplier (PMT)-based PET, but also a better prevention of the count-related rises in dead time and pile-up effects mainly due to smaller trigger domains (i.e., the detection surfaces associated with each trigger circuit). This study aimed to determine whether this latter property could help prevent against deteriorations in TOF resolution and TOF image quality in the wide range of PET count rates documented in clinical routine. Methods Variations, according to count rates, in timing resolution and in TOF-related enhancement of the quality of phantom images were compared between the first fully digital PET (Vereos) and a PMT-based PET (Ingenuity). Single-count rate values were additionally extracted from the list-mode data of routine analog- and digital-PET exams at each 500-ms interval, in order to determine the ranges of routine PET count rates. Results Routine PET count rates were lower for the Vereos than for the Ingenuity. For Ingenuity, the upper limits were estimated at approximately 21.7 and 33.2 Mcps after injection of respectively 3 and 5 MBq.kg-1 of current 18F-labeled tracers. At 5.8 Mcps, corresponding to the lower limit of the routine count rates documented with the Ingenuity, timing resolutions provided by the scatter phantom were 326 and 621 ps for Vereos and Ingenuity, respectively. At higher count rates, timing resolution was remarkably stable for Vereos but exhibited a progressive deterioration for Ingenuity, respectively reaching 732 and 847 ps at the upper limits of 21.7 and 33.2 Mcps. The averaged TOF-related gain in signal/noise ratio was stable at approximately 2 for Vereos but decreased from 1.36 at 5.8 Mcps to 1.14 and 1.00 at respectively 21.7 and 33.2 Mcps for Ingenuity. Conclusion Contrary to the Ingenuity PMT-based PET, the Vereos fully digital PET is unaffected by any deterioration in TOF resolution and consequently, in the quality of TOF images, in the wide range of routine PET count rates. This advantage is even more striking with higher count-rates for which the preferential use of digital PET should be further recommended (i.e., dynamic PET recording, higher injected activities).


Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1537
Author(s):  
Aneta Saletnik ◽  
Bogdan Saletnik ◽  
Czesław Puchalski

Raman spectroscopy is one of the main analytical techniques used in optical metrology. It is a vibration, marker-free technique that provides insight into the structure and composition of tissues and cells at the molecular level. Raman spectroscopy is an outstanding material identification technique. It provides spatial information of vibrations from complex biological samples which renders it a very accurate tool for the analysis of highly complex plant tissues. Raman spectra can be used as a fingerprint tool for a very wide range of compounds. Raman spectroscopy enables all the polymers that build the cell walls of plants to be tracked simultaneously; it facilitates the analysis of both the molecular composition and the molecular structure of cell walls. Due to its high sensitivity to even minute structural changes, this method is used for comparative tests. The introduction of new and improved Raman techniques by scientists as well as the constant technological development of the apparatus has resulted in an increased importance of Raman spectroscopy in the discovery and defining of tissues and the processes taking place in them.


2012 ◽  
Vol 1424 ◽  
Author(s):  
M. A. Mamun ◽  
A. H. Farha ◽  
Y. Ufuktepe ◽  
H. E. Elsayed-Ali ◽  
A. A. Elmustafa

ABSTRACTNanomechanical and structural properties of pulsed laser deposited niobium nitride thin films were investigated using X-ray diffraction, atomic force microscopy, and nanoindentation. NbN film reveals cubic δ-NbN structure with the corresponding diffraction peaks from the (111), (200), and (220) planes. The NbN thin films depict highly granular structure, with a wide range of grain sizes that range from 15-40 nm with an average surface roughness of 6 nm. The average modulus of the film is 420±60 GPa, whereas for the substrate the average modulus is 180 GPa, which is considered higher than the average modulus for Si reported in the literature due to pile-up. The hardness of the film increases from an average of 12 GPa for deep indents (Si substrate) measured using XP CSM and load control (LC) modes to an average of 25 GPa measured using the DCM II head in CSM and LC modules. The average hardness of the Si substrate is 12 GPa.


2003 ◽  
Vol 01 (03) ◽  
pp. 541-586 ◽  
Author(s):  
Tero Aittokallio ◽  
Markus Kurki ◽  
Olli Nevalainen ◽  
Tuomas Nikula ◽  
Anne West ◽  
...  

Microarray analysis has become a widely used method for generating gene expression data on a genomic scale. Microarrays have been enthusiastically applied in many fields of biological research, even though several open questions remain about the analysis of such data. A wide range of approaches are available for computational analysis, but no general consensus exists as to standard for microarray data analysis protocol. Consequently, the choice of data analysis technique is a crucial element depending both on the data and on the goals of the experiment. Therefore, basic understanding of bioinformatics is required for optimal experimental design and meaningful interpretation of the results. This review summarizes some of the common themes in DNA microarray data analysis, including data normalization and detection of differential expression. Algorithms are demonstrated by analyzing cDNA microarray data from an experiment monitoring gene expression in T helper cells. Several computational biology strategies, along with their relative merits, are overviewed and potential areas for additional research discussed. The goal of the review is to provide a computational framework for applying and evaluating such bioinformatics strategies. Solid knowledge of microarray informatics contributes to the implementation of more efficient computational protocols for the given data obtained through microarray experiments.


Ocean Science ◽  
2009 ◽  
Vol 5 (4) ◽  
pp. 661-684 ◽  
Author(s):  
C. Moore ◽  
A. Barnard ◽  
P. Fietzek ◽  
M. R. Lewis ◽  
H. M. Sosik ◽  
...  

Abstract. Requirements for understanding the relationships between ocean color and suspended and dissolved materials within the water column, and a rapidly emerging photonics and materials technology base for performing optical based analytical techniques have generated a diverse offering of commercial sensors and research prototypes that perform optical measurements in water. Through inversion, these tools are now being used to determine a diverse set of related biogeochemical and physical parameters. Techniques engaged include measurement of the solar radiance distribution, absorption, scattering, stimulated fluorescence, flow cytometry, and various spectroscopy methods. Selective membranes and other techniques for material isolation further enhance specificity, leading to sensors for measurement of dissolved oxygen, methane, carbon dioxide, common nutrients and a variety of other parameters. Scientists are using these measurements to infer information related to an increasing set of parameters and wide range of applications over relevant scales in space and time.


1997 ◽  
Vol 92 ◽  
pp. 359-371 ◽  
Author(s):  
E. Photos-Jones ◽  
A. Cottier ◽  
A. J. Hall ◽  
L. G. Mendoni

The island of Kea in the North Cyclades was well known in antiquity for its miltos, a naturally occurring red iron oxide valued for its colour and wide range of applications. By combining geological field work, physico-chemical analytical techniques, simulation (heating) experiments as well as simple laboratory tests, this paper describes the study of Kean iron oxides in an attempt to characterize this material which is still largely elusive in the archaeological record. The present work corroborates previous observations about the superior quality of some Kean iron oxides. Furthermore, it puts forward the hypothesis that miltos may have been considered an industrial mineral, and as such may have been used as an umbrella term for a variety of materials including mineralogically distinct purple as well as red iron oxides.


2002 ◽  
Author(s):  
Shinji Nagata ◽  
Bun Tsuchiya ◽  
K. Toh ◽  
N. Ohtsu ◽  
Tsunemi Kakuta ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document