scholarly journals Comparative Evaluation of Flexural Strength of Glass Ionomer Cement and Cention N in Artificial Medium Over Time Intervals - An In-Vitro Study

2021 ◽  
Vol 10 (32) ◽  
pp. 2609-2614
Author(s):  
Risana K. ◽  
Prathyusha P ◽  
Amith Adyanthaya ◽  
Aparna Sivaraman ◽  
Nazreen Ayub K ◽  
...  

BACKGROUND Glass ionomer cement (GIC) is a versatile restorative cement in paediatric dentistry. Due to its less flexural strength, alternative materials have been developed. Cention N is one such material, but since it’s a new material evidence is lacking regarding its physical properties, especially flexural strength for evaluating its clinical outcome. We wanted to compare the flexural strength of glass ionomer cement and Cention N stored in artificial saliva and its variation over different time intervals, i.e., after 24 hours, 1 week and 4 weeks. METHODS A total of 30 specimens were prepared for GIC (Fuji IX) and Cention N and were further categorized according to the duration of storage time of 24 hours, 1 week and 4 weeks (N = 10). A 3 - point bending test using a universal testing machine was used to evaluate the flexural strength. RESULTS GIC Fuji IX showed a mean flexural strength of 35.296 ± 1.61 Mpa at the end of 24 hours, 47.234 ± 4.12 after 1 week and 66.039 ± 11.05 Mpa at the end of 4 weeks. GIC showed a statistically significant increase of flexural strength from 24 hours to one week and a further increase after 4 weeks of storage. The flexural strength of Cention N at 24 hours was 175.985 ± 22.11 Mpa, at the end of one week was 163.486 ± 17.55 MPa, and after 4 weeks was 175.437 ± 27.22 Mpa. Cention N did not show any statistically significant change in flexural strength value from 24 hours to 4 weeks. Cention N showed highly significant difference between flexural strength compared to GIC at all - time intervals. CONCLUSIONS Cention N has a superior flexural strength compared to GIC at all - time intervals. KEY WORDS Cention N, Flexural Strength, Glass Ionomer Cement

2018 ◽  
Vol 27 (4) ◽  
pp. 372-377 ◽  
Author(s):  
Muhammad Ali Faridi ◽  
Abdul Khabeer ◽  
Saad Haroon

Objectives: Glass ionomer cement (GIC) is routinely placed as a restorative material in dentistry. However, due to its poor physical properties, its use is limited to cases where the level of stress on restoration is minimal. Improved formulations of GIC have been developed to overcome these drawbacks. The purpose of this study was to evaluate flexural strength of a conventional GIC (Fuji IX) against a newly developed glass carbomer cement (GCP). Materials and Methods: For Fuji IX and GCP, a total of 80 blocks were prepared and divided into 16 groups (n = 5). These groups were further categorized according to the storage medium (artificial saliva and Vaseline) and time intervals (24 h and 1, 2, and 4 weeks). A 3-point bending test was carried out, and statistical analysis was done using ANOVA and Tukey post hoc tests. Results: Fuji IX showed a mean flexural strength of 25.14 ± 13.02 versus 24.27 ± 12.57 MPa for GCP. There was no significant statistical difference between both materials when compared under storage media. Both materials showed the highest value for flexural strength at 2 weeks of storage and lowest at 4 weeks. Conclusion: The storage media do not affect the flexural strength of the specimens with reference to time. Time is the unique factor with relative influence on mean resistance to fracture. Further testing is required to evaluate the true potential of the newly developed GCP.


2014 ◽  
Vol 13 (2) ◽  
pp. 101
Author(s):  
Juliatri Juliatri ◽  
D.H.C. Pangemanan ◽  
Dwi Cahya Fitriyana

Immersion of glass ionomer cement (GIC) type II in acid drink like isotonic drink could reduce its compressive strength.This is due to the matrix degradation process of GIC in acid condition. However, there is artificial saliva that canneutralize this condition. The purpose of this study was to evaluate the effect of artificial saliva on compressive strengthof glass ionomer cement type II immersed in isotonic drink. The GICspecimens of 6 x 6 x 12 mm3beam were immersed for24 hours in distilled water, 24 hours in isotonic drink, 24 hours in isotonic drink continued with 72 hours in artificial saliva,48 hours in isotonic drink, and 48 hours in isotonic drink continued with 144 hours in artificial saliva. The compressivestrength was measured using Universal Testing Machine with a crosshead speed of 0.5 mm/min. Statistical analysis wasperformed by one-way ANOVA and post-hoc LSD test (=0.05) showed a significant difference of compressive strength(p<0,05). It was concluded that artificial saliva increases the compressive strength of GIC immersed in isotonic drink.


2018 ◽  
Vol 6 (3) ◽  
pp. 548-553 ◽  
Author(s):  
Bandar M. A. Al–Makramani ◽  
Abdul A. A. Razak ◽  
Mohamed I. Abu–Hassan ◽  
Fuad A. Al–Sanabani ◽  
Fahad M. Albakri

BACKGROUND: The selection of the appropriate luting cement is a key factor for achieving a strong bond between prepared teeth and dental restorations.AIM: To evaluate the shear bond strength of Zinc phosphate cement Elite, glass ionomer cement Fuji I, resin-modified glass ionomer cement Fuji Plus and resin luting cement Panavia-F to Turkom-Cera all-ceramic material.MATERIALS AND METHODS: Turkom-Cera was used to form discs 10mm in diameter and 3 mm in thickness (n = 40). The ceramic discs were wet ground, air - particle abraded with 50 - μm aluminium oxide particles and randomly divided into four groups (n = 10). The luting cement was bonded to Turkom-Cera discs as per manufacturer instructions. The shear bond strengths were determined using the universal testing machine at a crosshead speed of 0.5 mm/min. The data were analysed using the tests One Way ANOVA, the nonparametric Kruskal - Wallis test and Mann - Whitney Post hoc test.RESULTS: The shear bond strength of the Elite, Fuji I, Fuji Plus and Panavia F groups were: 0.92 ± 0.42, 2.04 ± 0.78, 4.37 ± 1.18, and 16.42 ± 3.38 MPa, respectively. There was the statistically significant difference between the four luting cement tested (p < 0.05).CONCLUSION: the phosphate-containing resin cement Panavia-F exhibited shear bond strength value significantly higher than all materials tested.


2003 ◽  
Vol 14 (3) ◽  
pp. 193-196 ◽  
Author(s):  
Simonides Consani ◽  
Julie Guzela dos Santos ◽  
Lourenço Correr Sobrinho ◽  
Mário Alexandre Coelho Sinhoreti ◽  
Manoel Damião Sousa-Neto

The relationship between metallic cast crowns and tensile strength according to cement types submitted to thermocycling was studied. Seventy-two metallic crowns were cast with Verabond II Ni-Cr alloy and cemented in standardized preparations with 10º tapering. Three types of finishing line (45-degree chamfered, 20-degree bevel shoulder and right shoulder) were made with diamond burs on bovine teeth. Twenty-four metallic crowns in each group were randomly subdivided into three subgroups of 8 samples each according to the cement used: SS White zinc phosphate cement, Vitremer resin-modified glass ionomer cement, and Rely X resin cement and were submitted to thermocycling. Retention was evaluated according to tensile load required to displace the metallic cast crowns from tooth preparations with an Instron testing machine. ANOVA and Tukey's test showed a statistically significant difference among luting materials, with greater results for Rely X resin cement (24.9 kgf) followed by SS White zinc phosphate cement (13.3 kgf) and Vitremer resin-modified glass ionomer cement (10.1 kgf). The finishing line types did not influence the tensile resistance of the crowns fixed with the three cements. Increased tensile resistance of metallic crowns fixed on bovine teeth was obtained with resin cement, independent of the finishing line types.


2018 ◽  
Vol 14 (1) ◽  
pp. 24
Author(s):  
Dr. Sazan Sherdil Saleem

The present study was aimed to evaluate and compare the compressive strength ofconventional glass ionomer cement with resin modified glass ionomer, compomer andmicrohybrid composite. A total of 40 specimens of esthetic restorative materials werefabricated using customized cylindrical teflon mould measuring 6mm height and 4mmdiameter and were grouped with ten specimens in each group, Group I: Conventionalglass ionomer cement (Fuji II). Group II: Resin modified glass ionomer (Fuji II LC).Group III: Compomer (Dyract AP) and Group IV: Microhybrid composite resin(Tetric Ceram).They were covered with Mylar strip and were cured using LED lightcuring unit. Compressive strength was evaluated using Universal testing machine. Theresult showed that there were a significant difference among the groups in whichTetric Ceram showed highest compressive strength and Fuji II showed the leastcompressive strength


2018 ◽  
Vol 32 (3) ◽  
pp. 127 ◽  
Author(s):  
Gabriela De Souza Balbinot ◽  
Isadora Martini Garcia ◽  
Susana Maria Werner Samuel ◽  
Fabricio Mezzomo Collares ◽  
Vicente Castelo Branco Leitune

OBJECTIVE: The aim of this study was to evaluate the influence of octacalcium phosphate (OCP) addition to conventional glass ionomer cement (GIC).METHODOLOGY: A commercial glass ionomer cement (Vidrion R – S.S. White Artigos Dentários Ltda – Rio de Janeiro, Brazil) was used in this study. OCP was added to powder in 1.5 and 3 wt%. GIC without OCP addition was used as control. Specimens were produced to evaluate radiopacity, setting time and diametral tensile strength of cements. Radiopacity was assessed by phosphor plate system with alluminium step-wedge for comparison. For setting time determination, Gilmore needle (100 g) was used to determine final setting reaction. Diametral tensile strength was measured in a universal testing machine. Data were analyzed by one-way ANOVA at a significance level of 95%.RESULTS: Results showed no statistically significant difference in tested properties with octacalcium phosphate addition in any concentration.CONCLUSION: OCP addition to GIC did not influence materials properties.


2012 ◽  
Vol 23 (4) ◽  
pp. 379-386 ◽  
Author(s):  
Adriano Augusto Melo de Mendonça ◽  
Camila Fávero de Oliveira ◽  
Josimeri Hebling ◽  
Carlos Alberto de Souza Costa

This study evaluated the transdentinal cytotoxicity (TC) and the bond strength (BS) of a resin-modified glass-ionomer cement (RMGIC) applied to dentin covered with smear layer (SL) of different thicknesses. Forty dentin discs had thick (TSL) or thin (THSL) smear layer created on their occlusal side. In artificial pulp chambers, MDPC-23 cells were seeded on the pulpal side of the dentin discs and divided into five groups: G1TC: no treatment (control); G2TC: TSL + RMGIC; G3TC: THSL + RMGIC; G4TC: TSL removal + RMGIC; G5TC: THSL removal + RMGIC. After 24 h, cell metabolism and morphology were evaluated by the methyltetrazolium (MTT) assay and by scanning electron microscopy (SEM), respectively. For BS, the following groups were determined: G1BS: TSL removal + RMGIC; G2BS: THSL removal + RMGIC; G3BS: TSL + RMGIC; G4BS: THSL + RMGIC. Shear bond strength was tested to failure in a mechanical testing machine MTS (0.5 mm/min). Statistically significant difference was observed only between the control and experimental groups (Kruskal-Wallis, p<0.05). The metabolic activity of the viable MDPC-23 cells in G2TC, G3TC, G4TC and G5TC decreased by 54.85%, 60.79%, 64.12% and 62.51%, respectively. Mean shear bond strength values for G1BS, G2BS, G3BS and G4BS were 7.5, 7.4, 6.4 and 6.7 MPa, respectively, without significant difference among them (ANOVA, p>0.05). RMGIC presented moderate transdentinal cytotoxic effects. Maintenance or removal of smear layer did not affect the bond strength of RMGIC to dentin substrate.


2003 ◽  
Vol 9 (1-2) ◽  
pp. 201-207 ◽  
Author(s):  
F. Saleh ◽  
N. Taymour

Shear and tensile bond strengths of 40 human and 40 bovine teeth were compared. Teeth were randomly assigned to group I, which received light-cured composite resin, or group II, which received light-cured resin-reinforced glass ionomer cement. The groups were subdivided for shear and tensile bond strength tests, which were conducted on a universal testing machine installed to a computer transducer. Statistical analysis revealed a highly significant difference between shear and tensile bond strengths of human and bovine enamel; however, regression prediction equations support the use of bovine teeth as a reliable substitute to human counterparts in bonding studies of orthodontic adhesion


Materials ◽  
2020 ◽  
Vol 13 (23) ◽  
pp. 5352
Author(s):  
Lamia Singer ◽  
Gabriele Bierbaum ◽  
Katja Kehl ◽  
Christoph Bourauel

Various medicinal plant parts and extracts have been proven to be sources of biologically active compounds, many of which have been incorporated in the production of new pharmaceutical compounds. Thus, the aim of this study was to increase the antimicrobial properties of a glass ionomer cement (GIC) through its modification with a mixture of plant extracts, which were evaluated along with a 0.5% chlorohexidine-modified GIC (CHX-GIC) with regard to the water sorption, solubility, and flexural strength. Methods: Salvadora persica, Olea europaea, and Ficus carcia leaves were prepared for extraction with ethyll alcohol using a Soxhlet extractor for 12 h. The plant extract mixture (PE) was added in three different concentrations to the water used for preparation of a conventional freeze-dried GIC (groups 1:1, 2:1, and 1:2). Specimens were then mixed according to the manufacturer’s instructions and tested against the unmodified GIC (control) and a GIC modified with 0.5% chlorhexidine. Water sorption and solubility were evaluated after 7 days of immersion in distilled water. Flexural strength was evaluated in a three-point bending test after 24 h using a universal material testing machine at a crosshead speed of 1 mm/min. One-way analysis of variance (ANOVA) was used for comparison between the groups. Tukey’s post hoc test was used for pairwise comparison when the ANOVA test was significant. Results: There were no statistically significant differences between the control (M = 20.5%), CHX-GIC (M = 19.6%), 1:1 (M = 20.0%), 1:2 (M = 19.5%), and 2:1 (19.7%) groups with regard to the percentage of water sorption, while for water solubility the 2:1 (M = −0.39%) plant-modified group was significantly different from all of the other groups. Flexural strength test results showed that the 2:1 group (M = 26.1 MPa) recorded significantly higher mean values compared to all other tested groups. Conclusion and clinical relevance: The plant extracts did not negatively affect the water sorption and solubility of the GIC, while the flexural strength was improved by the addition of the plant extract at higher concentrations.


2011 ◽  
Vol 264-265 ◽  
pp. 508-512
Author(s):  
Ammar A. Mustafa ◽  
Khalid A. S. Al-Khateeb ◽  
Ahmad Faris Ismail

Experimental glass ionomer cement was prepared for the purpose of this study. Twenty disk specimens (16mm diameter x 10mm height) of test-GIC were prepared for the diametral tensile strength (DTS) test and twenty cylindrical specimens (6 mm diameter x 16mm height) were prepared for the compressive strength (CS) test. Specimens were stored in an artificial saliva at 37º C and (50±10%) of relative humidity in an incubator until testing. Five specimens of each GIC were submitted to CS and DTS test in each period, namely 1 hour, 24 hours, 7 days and 28 days. The specimens were tested in a Universal Testing Machine (Instron 1122, Instron corp., High Wycombe, U.K.) at a crosshead speed of 1.0mm/min for CS and 0.5mm/min for the DTS test until failure occurred. The results have revealed that incorporation of lithium fluoride in the formula of the test GIC might impart an increase in the mechanical properties of the GICs