scholarly journals Optimization of a quantum weak measurement system with its working areas

2018 ◽  
Vol 26 (16) ◽  
pp. 21119 ◽  
Author(s):  
Yang Xu ◽  
Lixuan Shi ◽  
Tian Guan ◽  
Cuixia Guo ◽  
Dongmei Li ◽  
...  
2019 ◽  
Vol 114 (18) ◽  
pp. 181901 ◽  
Author(s):  
Yang Xu ◽  
Lixuan Shi ◽  
Tian Guan ◽  
Suyi Zhong ◽  
Xuesi Zhou ◽  
...  

2018 ◽  
Vol 57 (27) ◽  
pp. 7956 ◽  
Author(s):  
Yang Xu ◽  
Lixuan Shi ◽  
Tian Guan ◽  
Dongmei Li ◽  
Yuxuan Yang ◽  
...  

Sensors ◽  
2018 ◽  
Vol 18 (11) ◽  
pp. 3788 ◽  
Author(s):  
Yang Xu ◽  
Lixuan Shi ◽  
Tian Guan ◽  
Suyi Zhong ◽  
Xuesi Zhou ◽  
...  

We propose a self-referential fast detection scheme for a frequency domain weak measurement system for the detection of enantiomeric impurities in chiral molecules. In a transmissive weak measurement system, the optical rotation (OR) is used to modify the pre-selected polarization state and the post-selection polarization state. We obtained the sum and difference of the optical rotations produced by the sample and the standard by rotating the quarter wave plate in the system. Then, we estimate the ratio of chiral molecules to enantiomeric impurities using the ratio of the central wavelength shifts caused by the addition and subtraction states described above. In this paper, our system has an optical resolution of 1.88 × 10−5°. At the same time, we completed the detection of the ratio of the two substances in the mixture of L-proline and D-proline in different proportions, which proved that our system can quickly detect the content of enantiomeric impurities in chiral molecules.


2020 ◽  
Vol 12 (4) ◽  
pp. 1-12
Author(s):  
Yuxuan Yang ◽  
Yang Xu ◽  
Tian Guan ◽  
Lixuan Shi ◽  
Jinyu Li ◽  
...  

2017 ◽  
Vol 50 (49) ◽  
pp. 49LT01 ◽  
Author(s):  
Dongmei Li ◽  
Tian Guan ◽  
Yonghong He ◽  
Qinghua He ◽  
Yilong Zhang ◽  
...  

Sensors ◽  
2019 ◽  
Vol 19 (11) ◽  
pp. 2473
Author(s):  
Nian Xiong ◽  
Tian Guan ◽  
Yang Xu ◽  
Lixuan Shi ◽  
Suyi Zhong ◽  
...  

Self-reference detection is necessary and important to a biosensor. The linear weak measurement system based on total internal reflection has attracted widespread attention due to its high stability, label-free detection, and easy integration. In this paper, we propose a differential detection method based on the linear total internal reflection weak measurement system. We introduce the half-wave plate (HWP) to convert the H light and the V light to each other, thereby obtaining the difference in phase change of the optical path before and after the HWP. Experiments show that the system can not only achieve differential detection, but also has high stability. The linear differential weak measurement system proposed in this paper not only provides a new differential measurement method for real-time biosensors, but also enriches the types of weak measurement sensors.


2016 ◽  
Vol 41 (22) ◽  
pp. 5409 ◽  
Author(s):  
Yilong Zhang ◽  
Dongmei Li ◽  
Yonghong He ◽  
Zhiyuan Shen ◽  
Qinghua He

2021 ◽  
pp. 1-1
Author(s):  
Yang Xu ◽  
Lixuan Shi ◽  
Le Liu ◽  
Wenyue Xie ◽  
Tian Guan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document