scholarly journals High resolution on-chip optical filter array based on double subwavelength grating reflectors

2015 ◽  
Vol 23 (23) ◽  
pp. 29848 ◽  
Author(s):  
Yu Horie ◽  
Amir Arbabi ◽  
Seunghoon Han ◽  
Andrei Faraon
2016 ◽  
Vol 108 (22) ◽  
pp. 221106 ◽  
Author(s):  
Xinyuan Chong ◽  
Erwen Li ◽  
Kenneth Squire ◽  
Alan X. Wang

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Hwa-Seub Lee ◽  
Gyu-Weon Hwang ◽  
Tae-Yeon Seong ◽  
Jongkil Park ◽  
Jae Wook Kim ◽  
...  

AbstractMid-infrared wavelengths are called the molecular fingerprint region because it contains the fundamental vibrational modes inherent to the substances of interest. Since the mid-infrared spectrum can provide non-destructive identification and quantitative analysis of unknown substances, miniaturized mid-infrared spectrometers for on-site diagnosis have attained great concern. Filter-array based on-chip spectrometer has been regarded as a promising alternative. In this study, we explore a way of applying a pillar-type plasmonic nanodiscs array, which is advantageous not only for excellent tunability of resonance wavelength but also for 2-dimensional integration through a single layer process, to the multispectral filter array for the on-chip spectrometer. We theoretically and experimentally investigated the optical properties of multi-periodic triangular lattices of metal nanodiscs array that act as stopband filters in the mid-infrared region. Soft-mold reverse nanoimprint lithography with a subsequent lift-off process was employed to fabricate the multispectral filter array and its filter function was successfully extracted using a Fourier transform infrared microscope. With the measured filter function, we tested the feasibility of target spectrum reconstruction using a Tikhonov regularization method for an ill-posed linear problem and evaluated its applicability to the infrared spectroscopic sensor that monitors an oil condition. These results not only verify that the multispectral filter array composed of stopband filters based on the metal nanodiscs array when combined with the spectrum reconstruction technique, has great potential for use to a miniaturized mid-infrared on-chip spectrometer, but also provide effective guidance for the filter design.


Sensors ◽  
2018 ◽  
Vol 18 (8) ◽  
pp. 2622 ◽  
Author(s):  
Victoire Rérolle ◽  
Eric Achterberg ◽  
Mariana Ribas-Ribas ◽  
Vassilis Kitidis ◽  
Ian Brown ◽  
...  

Increasing atmospheric CO2 concentrations are resulting in a reduction in seawater pH, with potential detrimental consequences for marine organisms. Improved efforts are required to monitor the anthropogenically driven pH decrease in the context of natural pH variations. We present here a high resolution surface water pH data set obtained in summer 2011 in North West European Shelf Seas. The aim of our paper is to demonstrate the successful deployment of the pH sensor, and discuss the carbonate chemistry dynamics of surface waters of Northwest European Shelf Seas using pH and ancillary data. The pH measurements were undertaken using spectrophotometry with a Lab-on-Chip pH sensor connected to the underway seawater supply of the ship. The main processes controlling the pH distribution along the ship’s transect, and their relative importance, were determined using a statistical approach. The pH sensor allowed 10 measurements h−1 with a precision of 0.001 pH units and a good agreement with pH calculated from a pair of discretely sampled carbonate variables dissolved inorganic carbon (DIC), total alkalinity (TA) and partial pressure of CO2 (pCO2) (e.g., pHDICpCO2). For this summer cruise, the biological activity formed the main control on the pH distribution along the cruise transect. This study highlights the importance of high quality and high resolution pH measurements for the assessment of carbonate chemistry dynamics in marine waters.


2018 ◽  
Vol 26 (25) ◽  
pp. 33005 ◽  
Author(s):  
Yu He ◽  
Yong Zhang ◽  
Hongwei Wang ◽  
Yikai Su

2016 ◽  
Vol 108 (10) ◽  
pp. 101104 ◽  
Author(s):  
Tiecheng Zhu ◽  
Yiwen Hu ◽  
Pradip Gatkine ◽  
Sylvain Veilleux ◽  
Joss Bland-Hawthorn ◽  
...  

2020 ◽  
Vol 38 (16) ◽  
pp. 4447-4453
Author(s):  
Jun Zou ◽  
Xiao Ma ◽  
Xiang Xia ◽  
Jinhua Hu ◽  
Changhui Wang ◽  
...  

Sensors ◽  
2020 ◽  
Vol 20 (12) ◽  
pp. 3416 ◽  
Author(s):  
Nikolay Lvovich Kazanskiy ◽  
Svetlana Nikolaevna Khonina ◽  
Muhammad Ali Butt

In this paper, a racetrack ring resonator design based on a subwavelength grating double slot waveguide is presented. The proposed waveguide scheme is capable of confining the transverse electric field in the slots and the gaps between the grating segments. This configuration facilitates a large light–matter interaction which elevates the sensitivity of the device approximately 2.5 times higher than the one that can be obtained via a standard slot waveguide resonator. The best sensitivity of the design is obtained at 1000 nm/RIU by utilizing a subwavelength grating double slot waveguide of period 300 nm. The numerical study is conducted via 2D and 3D finite element methods. We believe that the proposed sensor design can play an important role in the realization of highly sensitive lab-on-chip sensors.


Sign in / Sign up

Export Citation Format

Share Document