Dynamic surface profiling with synthetic holographic confocal microscopy

Author(s):  
M. Schnell ◽  
P. S. Carney ◽  
R. Hillenbrand
2000 ◽  
Vol 39 (25) ◽  
pp. 4621 ◽  
Author(s):  
J. Felix Aguilar ◽  
Mario Lera ◽  
Colin J. R. Sheppard

Sensors ◽  
2020 ◽  
Vol 20 (24) ◽  
pp. 7347
Author(s):  
Dawoon Jeong ◽  
Se Jin Park ◽  
Hansol Jang ◽  
Hyunjoo Kim ◽  
Jaesun Kim ◽  
...  

Chromatic confocal microscopy (CCM) has been intensively developed because it can exhibit effective focal position scanning based on the axial chromatic aberration of broadband light reflected from a target. To improve the imaging speed of three-dimensional (3D) surface profiling, we have proposed the novel concept of swept-source-based CCM (SS-CCM) and investigated the usefulness of the corresponding imaging system. Compared to conventional CCM based on a broadband light source and a spectrometer, a swept-source in the proposed SS-CCM generates light with a narrower linewidth for higher intensity, and a single photodetector employed in the system exhibits a fast and sensitive response by immediately obtaining spectrally encoded depth from a chromatic dispersive lens array. Results of the experiments conducted to test the proposed SS-CCM system indicate that the system exhibits an axial chromatic focal distance range of approximately 360 μm for the 770–820 nm swept wavelength range. Moreover, high-speed surface profiling images of a cover glass and coin were successfully obtained with a short measurement time of 5 ms at a single position.


Author(s):  
Oliver C. Wells ◽  
Mark E. Welland

Scanning tunneling microscopes (STM) exist in two versions. In both of these, a pointed metal tip is scanned in close proximity to the specimen surface by means of three piezos. The distance of the tip from the sample is controlled by a feedback system to give a constant tunneling current between the tip and the sample. In the low-end STM, the system has a mechanical stability and a noise level to give a vertical resolution of between 0.1 nm and 1.0 nm. The atomic resolution STM can show individual atoms on the surface of the specimen.A low-end STM has been put into the specimen chamber of a scanning electron microscope (SEM). The first objective was to investigate technological problems such as surface profiling. The second objective was for exploratory studies. This second objective has already been achieved by showing that the STM can be used to study trapping sites in SiO2.


Author(s):  
David W. Piston ◽  
Brian D. Bennett ◽  
Robert G. Summers

Two-photon excitation microscopy (TPEM) provides attractive advantages over confocal microscopy for three-dimensionally resolved fluorescence imaging and photochemistry. Two-photon excitation arises from the simultaneous absorption of two photons in a single quantitized event whose probability is proportional to the square of the instantaneous intensity. For example, two red photons can cause the transition to an excited electronic state normally reached by absorption in the ultraviolet. In practice, two-photon excitation is made possible by the very high local instantaneous intensity provided by a combination of diffraction-limited focusing of a single laser beam in the microscope and the temporal concentration of 100 femtosecond pulses generated by a mode-locked laser. Resultant peak excitation intensities are 106 times greater than the CW intensities used in confocal microscopy, but the pulse duty cycle of 10-5 maintains the average input power on the order of 10 mW, only slightly greater than the power normally used in confocal microscopy.