Availability of the Emergency Core Cooling System of a CANDU Pressurized Heavy-Water Reactor Following a Small Loss-of-Coolant Accident

1985 ◽  
Vol 69 (3) ◽  
pp. 293-307
Author(s):  
Tawfik A. Al-Kusayer
Author(s):  
P. Saha ◽  
B. K. Rakshit ◽  
P. Mukhopadhyay

Abstract The present paper discusses the development of a computer software or code for a best-estimate analysis of Pressure Suppression Pool Hydrodynamics in a Pressurized Heavy Water Reactor (PHWR) system during a Loss-of-Coolant Accident (LOCA) at the primary heat transport system. The software has been developed on Microcomputers, namely, PC-XT or AT (286) under MS-DOS operating system.


Author(s):  
Alan J. Bilanin ◽  
Andrew E. Kaufman ◽  
Warren J. Bilanin

Boiling Water Reactor pressure suppression pools have stringent housekeeping requirements, as well as restrictions on amounts and types of insulation and debris that can be present in the containment, to guarantee that suction strainers that allow cooling water to be supplied to the reactor during a Loss of Coolant Accident remain operational. By introducing “good debris” into the cooling water, many of these requirements/restrictions can be relaxed without sacrificing operational readiness of the cooling system.


Author(s):  
H. G. Lele ◽  
A. Srivastava ◽  
B. Chatterjee ◽  
A. J. Gaikwad ◽  
Rajesh Kumar ◽  
...  

Safety of nuclear reactor needs to be assessed against different categories of Postulated initiating events. Advanced Heavy Water Reactor is natural circulation light water cooled and heavy water moderated pressure tube type of reactor. Inventory of the system is important parameter in determination of flow characteristics of this natural circulation reactor. In view of this, various events that cause changes in PHT system inventory are analysed in this paper. One of the reason for decrease in coolant inventory is hypothetical Loss of coolant accident (LOCA) This event is of very low probability but important from designing engineered safeguard system of a reactor. Loss of coolant accident in a nuclear reactor can cause voiding of the reactor core due to expulsion of primary coolant from break. In such, a situation the reactor core experiences very low heat removal rate from the nuclear fuel though the decay heat generation continues even after tripping of the reactor. Heat generation in the reactor core is due to various sources such as decay heat, stored heat etc, can lead to heating of fuel elements. However, Emergency core cooling systems of the reactor are actuated and prevent undesirable temperature rise. These events are called design basis events and focus is on adequacy of Emergency Core Cooling System (ECCS) and fuel integrity. The scenarios, phenomena encountered and consequences depend upon size and location of break, system characteristics, and actuation and capability of different protection and engineered safeguard systems of the reactor system. Moreover, this reactor has several passive features to ensure safety of this reactor. which are considered in analyzing these events. Events under category of decrease in coolant inventory includes loss of coolant accidents due to break at different locations of different sizes. Various locations considered in this paper are steam line, inlet header, inlet feeder, ECCS header, downcomer, pressure tube, Isolation condenser inlet header, instrument line break at inlet header and steam drum. The paper also considers scenario emerging due to malfunctions like relief valve stuck open. Causes for events under category of increase in coolant inventory are Increase in Drum level controller set point, Inadvertent valving in of Accumulators and Inadvertent valving in of Gravity driven water pool (GDWP). Last two events are not analysed as they are not possible. The analysis for the above events is complex due to various complex and wide ranges of phenomena involved during different pies under this category. It involves single and two phase natural circulation at different power levels, inventories and pressures, two-phase natural circulation under depleted inventory conditions. Coupled neutronics and thermal hydraulics behaviour, Phenomena under LOCA, phenomena during ECCS injection, direct injection into fuel rod, advanced accumulator injection., vapour pull through and coupled controller and thermal hydraulics. Modelling of these phenomena for each event is discussed in this paper. In this paper summary of analyses for representive event is presented.


Author(s):  
P. Saha ◽  
T. K. Das ◽  
A. Chanda ◽  
S. Ray

Abstract The present paper discusses the development of a computer software or code for best-estimate analysis of Loss-of-Coolant Accident (LOCA) in Pressurized Heavy Water Reactor (PHWR) systems. The formulation is comparable to U.S., Canadian, French LOCA codes, namely, TRAC, RELAPS, ATHENA, CATHARE, etc. However, the present software has been developed on Microcomputers, namely, PC-XT and AT, whereas the other softwares were developed and are being used primarily on Mainframes such as CDC-7600, CYBER-176, CRAY, etc.


2011 ◽  
Vol 133 (1) ◽  
Author(s):  
P. Majumdar ◽  
B. Chatterjee ◽  
G. Nandan ◽  
D. Mukhopadhyay ◽  
H. G. Lele

In Indian pressurized heavy water reactor (PHWR), loss of coolant accident with simultaneous failure of emergency core cooling system can lead to significant temperature rise in the pressure tube (PT) with the system internal pressure varying from 9 MPa to 0.1 MPa during the event. This high temperature can cause metallurgical and geometrical changes in the PT. PT would deform plastically due to internal pressure and fuel weight. A computer code “PTCREEP” based on physical models was developed to simulate the ballooning deformation expected during the channel heatup condition under internal pressure. This paper presents the assessment of the code PTCREEP against the set of experiments conducted with PT material used in Indian PHWRs.


Nukleonika ◽  
2015 ◽  
Vol 60 (2) ◽  
pp. 339-345 ◽  
Author(s):  
Tomasz Bury

Abstract The problem of hydrogen behavior in containment buildings of nuclear reactors belongs to thermal-hydraulic area. Taking into account the size of systems under consideration and, first of all, safety issues, such type of analyses cannot be done by means of full-scale experiments. Therefore, mathematical modeling and numerical simulations are widely used for these purposes. A lumped parameter approach based code HEPCAL has been elaborated in the Institute of Thermal Technology of the Silesian University of Technology for simulations of pressurized water reactor containment transient response. The VVER-440/213 and European pressurised water reactor (EPR) reactors containments are the subjects of analysis within the framework of this paper. Simulations have been realized for the loss-of-coolant accident scenarios with emergency core cooling system failure. These scenarios include core overheating and hydrogen generation. Passive autocatalytic recombiners installed for removal of hydrogen has been taken into account. The operational efficiency of the hydrogen removal system has been evaluated by comparing with an actual hydrogen concentration and flammability limit. This limit has been determined for the three-component mixture of air, steam and hydrogen. Some problems related to the lumped parameter approach application have been also identified.


2017 ◽  
Vol 19 (2) ◽  
pp. 59 ◽  
Author(s):  
Anhar Riza Antariksawan ◽  
Surip Widodo ◽  
Hendro Tjahjono

A postulated loss of coolant accident (LOCA) shall be analyzed to assure the safety of a research reactor. The analysis of such accident could be performed using best estimate thermal-hydraulic codes, such as RELAP5. This study focuses on analysis of LOCA in TRIGA-2000 due to pipe and beam tube break. The objective is to understand the effect of break size and the actuating time of the emergency core cooling system (ECCS) on the accident consequences and to assess the safety of the reactor. The analysis is performed using RELAP/SCDAPSIM codes. Three different break size and actuating time were studied. The results confirmed that the larger break size, the faster coolant blow down. But, the siphon break holes could prevent the core from risk of dry out due to siphoning effect in case of pipe break. In case of beam tube rupture, the ECCS is able to delay the fuel temperature increased where the late actuation of the ECCS could delay longer. It could be concluded that the safety of the reactor is kept during LOCA throughout the duration time studied. However, to assure the integrity of the fuel for the long term, the cooling system after ECCS last should be considered.  Keywords: safety analysis, LOCA, TRIGA, RELAP5 STUDI PARAMETRIK LOCA DI TRIGA-2000 MENGGUNAKAN RELAP5/SCDAP. Kecelakaan kehilangan air pendingin (LOCA) harus dianalisis untuk menjamin keselamatan suatu reaktor riset. Analisis LOCA dapat dilakukan menggunakan perhitungan best-estimate seperti RELAP5. Penelitian ini menekankan pada analisis LOCA di TRIGA-2000 akibat pecahnya pipa dan tabung berkas. Tujuan penelitian adalah memahami efek ukuran kebocoran dan waktu aktuasi sistem pendingin teras darurat (ECCS) pada sekuensi kejadian dan mengkaji keselamatan reaktor. Analisis dilakukan menggunakan program perhitungan RELAP/SCDAPSIM. Tiga ukuran kebocoran dan waktu aktuasi ECCS berbeda dipilih sebagai parameter dalam studi ini.  Hasil perhitungan mengonfirmasi bahwa semakin besar ukuran kebocoran, semakin cepat pengosongan tangki reaktor. Lubang siphon breaker dapat mencegah air terkuras dalam hal kebocoran pada pipa. Sedang dalam hal kebocoran pada beam tube, ECCS mampu memperlambat kenaikan temperatur bahan bakar. Dari studi ini dapat disimpulkan bahwa keselamatan reaktor dapat terjaga pada kejadian LOCA, namun pendinginan jangka panjang perlu dipertimbangkan untuk menjaga integritas bahan bakar.Kata kunci: analisis keselamatan, LOCA, TRIGA, RELAP5


2020 ◽  
Vol 01 (02) ◽  
pp. 53-60
Author(s):  
Pronob Deb Nath ◽  
Kazi Mostafijur Rahman ◽  
Md. Abdullah Al Bari

This paper evaluates the thermal hydraulic behavior of a pressurized water reactor (PWR) when subjected to the event of Loss of Coolant Accident (LOCA) in any channel surrounding the core. The accidental break in a nuclear reactor may occur to circulation pipe in the main coolant system in a form of small fracture or equivalent double-ended rupture of largest pipe connected to primary circuit line resulting potential threat to other systems, causing pressure difference between internal parts, unwanted core shut down, explosion and radioactivity release into environment. In this computational study, LOCA for generation III+ VVER-1200 reactor has been carried out for arbitrary break at cold leg section with and without Emergency Core Cooling System (ECCS). PCTRAN, a thermal hydraulic model-based software developed using real data and computational approach incorporating reactor physics and control system was employed in this study. The software enables to test the consequences related to reactor core operations by monitoring different operating variables in the system control bar. Two types of analysis were performed -500% area break at cold leg pipe due to small break LOCA caused by malfunction of the system with and without availability of ECCS. Thermal hydraulic parameters like, coolant dynamics, heat transfer, reactor pressure, critical heat flux, temperature distribution in different sections of reactor core have also been investigated in the simulation. The flow in the reactor cooling system, steam generators steam with feed-water flow, coolant steam flow through leak level of water in different section, power distribution in core and turbine were plotted to analyze their behavior during the operations. The simulation showed that, LOCA with unavailability of Emergency Core Cooling System (ECCS) resulted in core meltdown and release of radioactivity after a specific time.


Sign in / Sign up

Export Citation Format

Share Document