Probabilistic Study on Accidental Torsion of Low-Rise Buildings

2004 ◽  
Vol 20 (1) ◽  
pp. 25-41 ◽  
Author(s):  
Jaime De-la-Colina ◽  
Cristina Almeida

A probabilistic study on accidental torsion is presented. Multistory shear systems, representative of low-rise buildings and subjected to bidirectional earthquake ground motions are considered. Ductility demands of lateral resisting elements (LREs) due to uncertainties on (1) center-of-mass locations, (2) LRE stiffness, and (3) LRE yield forces were studied. Building code recommendations on accidental torsion as well as the effects of both eccentricity and lateral-force reduction factor are assessed. Results indicate that considering one random variable in the accidental torsion problem can lead to larger ductility-demand probabilities of exceedance than using two or more variables. Individual effects of each one of the variables considered are not superimposed when all variables take place at the same time. For systems designed for torsion, ductility demands of LREs decreases for increasing eccentricities. Increments of yield forces and decrements of probabilities of exceedance due to the use of increasing values of factor β associated with the accidental eccentricity are presented.

1993 ◽  
Vol 9 (1) ◽  
pp. 121-135 ◽  
Author(s):  
Chia-Ming Uang

The two-level design philosophy is recognized by modern seismic codes. When this philosophy is implemented in the code, the intensities of the two design earthquakes, the structural performance criteria, explicit versus implicit design approach, and the effectiveness to achieve the performance criteria vary considerably from one code to the other. For the ultimate limit state, the UBC was compared with seismic codes of Canada, Japan, and Eurocode. It was found that a trend to deviate from the UBC approach of using a single seismic force reduction factor (i.e., Rw) is apparent. Instead, an approach using a compound force reduction factor which considers the contribution of structural ductility and structural overstrength is preferred. For the serviceability limit state, a comparison of the level of design earthquakes and performance criteria of the UBC, Tri-Services Manual, and the Japanese code indicates that the UBC produces the most flexible structure, and that UBC does not control structural damage. It is suggested that the UBC adopts an explicit serviceability design procedure.


2006 ◽  
Vol 22 (1) ◽  
pp. 267-286 ◽  
Author(s):  
Jorge L. Varela ◽  
Jennifer E. Tanner ◽  
Richard E. Klingner

This paper addresses the development and application of a rational procedure to select the seismic force reduction factor ( R) and the displacement amplification factor ( Cd) for the design of autoclaved aerated concrete (AAC) structures. The values of R and Cd are proposed based on a combination of laboratory test results and numerical simulation. The test results are obtained from 14 AAC shear-wall specimens tested under simulated gravity and quasi-static reversed cyclic lateral loads. Analytical responses are predicted using nonlinear analysis models whose hysteretic characteristics are based on the experimentally observed responses. Using an iterative procedure, typical AAC structures are designed using successively larger trial values of the factor, R, until the structure's response (either ductility or drift) exceeds the experimentally determined capacity. A lower fractile of those critical values, modified for probable structural overstrength, is taken as a reasonable value of 3 for R. Using an analogous procedure, a reasonable value of Cd is determined as 3. These values will undoubtedly be refined based on field experience, just as they have been for other structural systems.


1991 ◽  
Vol 18 (4) ◽  
pp. 568-574 ◽  
Author(s):  
W. K. Tso ◽  
N. Naumoski

The seismic force reduction factors proposed in the seismic provisions of the National Building Code of Canada 1990 (NBCC 1990) are examined using ground motion records from two recent Canadian earthquakes. The displacement ductility demands are analyzed for structural systems with different ductility capacity. It is found that the NBCC 1990 force reduction factors, which are period independent, lead to a very high ductility demand for short-period structural systems. To avoid this, two types of period-dependent force reduction factors for short-period structures are investigated. The results show that the linearly varying period-dependent reduction factor represents a viable means to resolve the high ductility problems associated with short-period structural systems. Key words: earthquake, seismic, design, code, response, spectra, ductility, reduction factor, base shear.


2003 ◽  
Vol 19 (1) ◽  
pp. 47-66 ◽  
Author(s):  
Jaime De-la-Colina

Multistory models are studied to assess design recommendations for torsionally unbalanced multistory buildings. Structural systems are assumed as shear beams with nonlinear lateral-resisting elements oriented along two orthogonal directions and subjected to a bidirectional earthquake ground motion. Five-story rigid-diaphragm models with mass or stiffness eccentricity are considered in the study. Accidental eccentricity is not included in the modeling and, therefore, its related recommendations are not assessed. Design recommendations studied here are based on the simple static procedure and include two values and an expression for the amplification factor α to compute story eccentricities, three values of the torsion-shear reduction factor δ, an additional lateral force Ft to be applied at the building top level, and a minimal story eccentricity for the building. Design recommendations to control ductility demands of torsionally unbalanced multistory buildings are given.


Author(s):  
J. B. Berrill ◽  
M. J. N. Priestley ◽  
R. Peek

This paper provides background material to the loadings section
of the model code recently published by the Society's Discussion Group
on Bridge Design, and presents a preliminary re-evaluation of the design spectra given in the proposed code. The basis for the proposed zoning scheme, in which the present uniform Zone B is replaced by a transition zone, is discussed. Arguments are given underlying the return period coefficients, and the force reduction factor used in generating the inelastic response spectra of the code. It is likely that the design spectra and the values of the other coefficients determining base shear forces will need to be revised as further research results become available; however, the form of the base shear expression, and the loadings section
as a whole, should remain unchanged. Re-evaluated spectra suggest that
the seismic coefficient values given in the proposed code may be too large by about 25 percent in Zone A, and too low by as much as 40 percent in
 Zone C. While the reassessed values should be more reliable than the original ones, they are based on a Japanese attenuation model, which has
not yet been calibrated against New Zealand data. Further research is required to establish an appropriate attenuation model for New Zealand;
 to avoid undue proliferation of design loadings it is preferable to defer revision of the various coefficients in the proposed code until such a
model is available. Until this is done, the proposed spectra should be viewed with caution, particularly in Zone C.


1994 ◽  
Vol 21 (3) ◽  
pp. 363-376 ◽  
Author(s):  
André Filiatrault ◽  
Danilo D'Aronco ◽  
René Tinawi

During severe earthquakes, ductile flexural walls are expected to exhibit inelastic flexural behaviour while other brittle deformation mechanisms, such as shear, should remain elastic. The philosophy of the Canadian seismic provisions for flexural walls is based on the assumption that the force reduction factor is applicable to both flexure and shear. If the bending moments are limited because of the flexural strength of a wall, then the shear forces are considered to be limited by the same ratio. Recent case studies have not confirmed this philosophy. Brittle shear failures in walls are still possible even if their shear strengths are established by the Canadian standards. This paper presents an analytical investigation on the shear demand of ductile flexural walls designed for three different seismic zones in Canada. For each zone, an ensemble of code compatible historical earthquake ground motions is identified. The shear demand of each structure, under each earthquake record, is obtained by nonlinear time-history dynamic analyses. In 77% of the cases, the computed dynamic shear demand is higher than the current code shear strength. To address this issue, a force modification factor for shear, different from the one for flexure, is suggested for the Canadian code. Key words: earthquake, seismic response, shear walls.


2018 ◽  
Vol 2 (3) ◽  
pp. 14-29
Author(s):  
N. Ahmad ◽  
Q. Ali ◽  
M. Javed ◽  
◽  
◽  
...  

2000 ◽  
Vol 16 (1) ◽  
pp. 285-307 ◽  
Author(s):  
Mark Yashinsky ◽  
Thomas Ostrom

Caltrans' Seismic Design Criteria (SDC) has been adopted as the minimum seismic standard for ordinary bridges on California's highways. The SDC is a compilation of new and existing seismic criteria that had been previously documented in a variety of Caltrans documents. The SDC extends the capacity design philosophy introduced in the 1980 Caltrans Bridge Design Specifications. The most significant departure from the previous procedure is that ductile members are now designed by comparing the displacement demand to the displacement capacity. The demands are generated by a linear elastic analysis, and the capacities are determined from a curvature analysis that incorporates the nonlinear behavior of the structural elements. The demand/capacity methodology supplants the previous method based on reducing the elastic dynamic forces by a force reduction factor. In this paper, the significant features of Caltrans' SDC are described.


Sign in / Sign up

Export Citation Format

Share Document