scholarly journals Connectome sorting by consensus clustering increases separability in group neuroimaging studies

2019 ◽  
Vol 3 (2) ◽  
pp. 325-343 ◽  
Author(s):  
Javier Rasero ◽  
Ibai Diez ◽  
Jesus M. Cortes ◽  
Daniele Marinazzo ◽  
Sebastiano Stramaglia

A fundamental challenge in preprocessing pipelines for neuroimaging datasets is to increase the signal-to-noise ratio for subsequent analyses. In the same line, we suggest here that the application of the consensus clustering approach to brain connectivity matrices can be a valid additional step for connectome processing to find subgroups of subjects with reduced intragroup variability and therefore increasing the separability of the distinct subgroups when connectomes are used as a biomarker. Moreover, by partitioning the data with consensus clustering before any group comparison (for instance, between a healthy population vs. a pathological one), we demonstrate that unique regions within each cluster arise and bring new information that could be relevant from a clinical point of view.

2018 ◽  
Author(s):  
Javier Rasero ◽  
Jesus M Cortes ◽  
Daniele Marinazzo ◽  
Sebastiano Stramaglia

AbstractOne of the biggest challenges in preprocessing pipelines for neuroimaging data is to increase the signal-to-noise ratio of the data which will be used for subsequent analyses. In the same line, we suggest in the present work that the application of consensus clustering for brain connectivity matrices to find subgroups of subjects can be a valid additional”connectome processing” step helpful to reduce intra-group variability and therefore increase the separability of distinct classes. In addition, by partitioning the data before any group comparison, we demonstrate that unique regions within each cluster arise and bring new information that could be relevant from a clinical point of view.


1994 ◽  
Vol 04 (02) ◽  
pp. 441-446 ◽  
Author(s):  
V.S. ANISHCHENKO ◽  
M.A. SAFONOVA ◽  
L.O. CHUA

Using numerical simulation, we establish the possibility of realizing the stochastic resonance (SR) phenomenon in Chua’s circuit when it is excited by either an amplitude-modulated or a frequency-modulated signal. It is shown that the application of a frequency-modulated signal to a Chua’s circuit operating in a regime of dynamical intermittency is preferable over an amplitude-modulated signal from the point of view of minimizing the signal distortion and maximizing the signal-to-noise ratio (SNR).


2018 ◽  
Vol 42 (1) ◽  
pp. 167-174 ◽  
Author(s):  
V. I. Parfenov ◽  
D. Y. Golovanov

An algorithm for estimating time positions and amplitudes of a periodic pulse sequence from a small number of samples was proposed. The number of these samples was determined only by the number of pulses. The performance of this algorithm was considered on the assumption that the spectrum of the original signal is limited with an ideal low-pass filter or the Nyquist filter, and conditions for the conversion from one filter to the other were determined. The efficiency of the proposed algorithm was investigated through analyzing in which way the dispersion of estimates of time positions and amplitudes depends on the signal-to-noise ratio and on the number of pulses in the sequence. It was shown that, from this point of view, the efficiency of the algorithm decreases with increasing number of sequence pulses. Besides, the efficiency of the proposed algorithm decreases with decreasing signal-to-noise ratio.It was found that, unlike the classical maximum likelihood algorithm, the proposed algorithm does not require a search for the maximum of a multivariable function, meanwhile characteristics of the estimates are practically the same for both these methods. Also, it was shown that the estimation accuracy of the proposed algorithm can be increased by an insignificant increase in the number of signal samples.The results obtained may be used in the practical design of laser communication systems, in which the multipulse pulse-position modulation is used for message transmission. 


2021 ◽  
Vol 9 ◽  
Author(s):  
Zahra Sobhani ◽  
Yunlong Luo ◽  
Christopher T. Gibson ◽  
Youhong Tang ◽  
Ravi Naidu ◽  
...  

As an emerging contaminant, microplastic is receiving increasing attention. However, the contamination source is not fully known, and new sources are still being identified. Herewith, we report that microplastics can be found in our gardens, either due to the wrongdoing of leaving plastic bubble wraps to be mixed with mulches or due to the use of plastic landscape fabrics in the mulch bed. In the beginning, they were of large sizes, such as > 5 mm. However, after 7 years in the garden, owing to natural degradation, weathering, or abrasion, microplastics are released. We categorize the plastic fragments into different groups, 5 mm–0.75 mm, 0.75 mm–100 μm, and 100–0.8 μm, using filters such as kitchenware, meaning we can collect microplastics in our gardens by ourselves. We then characterized the plastics using Raman image mapping and a logic-based algorithm to increase the signal-to-noise ratio and the image certainty. This is because the signal-to-noise ratio from a single Raman spectrum, or even from an individual peak, is significantly less than that from a spectrum matrix of Raman mapping (such as 1 vs. 50 × 50) that contains 2,500 spectra, from the statistical point of view. From the 10 g soil we sampled, we could detect the microplastics, including large (5 mm–100 μm) fragments and small (<100 μm) ones, suggesting the degradation fate of plastics in the gardens. Overall, these results warn us that we must be careful when we do gardening, including selection of plastic items for gardens.


Genes ◽  
2019 ◽  
Vol 10 (9) ◽  
pp. 666 ◽  
Author(s):  
Al-Azzawi ◽  
Ouadou ◽  
Tanner ◽  
Cheng

Structure determination of proteins and macromolecular complexes by single-particle cryo-electron microscopy (cryo-EM) is poised to revolutionize structural biology. An early challenging step in the cryo-EM pipeline is the detection and selection of particles from two-dimensional micrographs (particle picking). Most existing particle-picking methods require human intervention to deal with complex (irregular) particle shapes and extremely low signal-to-noise ratio (SNR) in cryo-EM images. Here, we design a fully automated super-clustering approach for single particle picking (SuperCryoEMPicker) in cryo-EM micrographs, which focuses on identifying, detecting, and picking particles of the complex and irregular shapes in micrographs with extremely low signal-to-noise ratio (SNR). Our method first applies advanced image processing procedures to improve the quality of the cryo-EM images. The binary mask image-highlighting protein particles are then generated from each individual cryo-EM image using the super-clustering (SP) method, which improves upon base clustering methods (i.e., k-means, fuzzy c-means (FCM), and intensity-based cluster (IBC) algorithm) via a super-pixel algorithm. SuperCryoEMPicker is tested and evaluated on micrographs of β-galactosidase and 80S ribosomes, which are examples of cryo-EM data exhibiting complex and irregular particle shapes. The results show that the super-particle clustering method provides a more robust detection of particles than the base clustering methods, such as k-means, FCM, and IBC. SuperCryoEMPicker automatically and effectively identifies very complex particles from cryo-EM images of extremely low SNR. As a fully automated particle detection method, it has the potential to relieve researchers from laborious, manual particle-labeling work and therefore is a useful tool for cryo-EM protein structure determination.


1997 ◽  
Vol 500 ◽  
Author(s):  
Š. Lányi ◽  
M. Hruškovic

ABSTRACTThe operation principle and main properties of a Scanning Capacitance Microscope (SCM) are described. It is called low-frequency, because in its design typical low-frequency techniques are utilised. The main attention is focused on its lateral resolution, signal-to-noise ratio and the possibility to detect dielectric losses.Mapping the electrostatic field of a shielded microscope probe was used to calculate the stray capacitance, flux density, sensitivity and contrast obtained on a flat conducting surface, as well as on a surface covered by a thin dielectric film. The effect of dielectric losses, represented by a parallel conductance, on the detected capacitance and the resulting phase shift has been derived.Using the results of mapping, the requirements on a SCM input stage and the possible solutions are discussed. From the point of view of frequency range and noise the best is an electrometric input stage, with input impedance represented by its capacitance.The achieved signal-to-noise ratio of the low frequency Scanning Capacitance Microscope renders the extension of the working frequency range to lower frequencies. The input stage can be optimised for a frequency range from about 1 kHz to a few MHz, with the possibility to extend it to about 10 MHz at the cost of reduced sensitivity at the lowest frequencies.


Sensors ◽  
2020 ◽  
Vol 20 (21) ◽  
pp. 6195
Author(s):  
Florian Hau ◽  
Florian Baumgärtner ◽  
Martin Vossiek

As the demands on modern radar systems with respect to accuracy, reliability, and availability increase, a detailed assessment of the influence of nonlinear movements has become necessary. In particular, from the point of view of radar, different types of movements, such as any kind of acceleration, braking situation, or vehicle vibration, are essential parts of any traffic scenario. These unavoidable motions, in which the relative velocity changes within one measurement cycle, are called nonlinear movements. These nonlinearities contribute to intermediate frequencies, which are comparable to the extensively described nonlinearities of a frequency ramp. This additional contribution to the intermediate signal has a direct effect on the signal-to-noise ratio and thus on the accuracy and probability of target detection. This paper presents a study of various types of nonlinear motion and a detailed definition of the resulting parameters based on a variety of vehicle-based measurements. An advanced signal model of frequency-modulated continuous wave (FMCW) radar is introduced and verified in addition to a detailed mathematical description of spectral signal behaviour in sinusoidal motions and linear acceleration. The theoretical and experimental results in idealised point targets are transferred to real complex road users. Furthermore, by applying established automotive signal processing steps in the form of an ordered statistical constant false alarm rate (OS CFAR), the consequences of determining the noise level are also shown. In combination with the already introduced signal behaviour, these results enabled general description of the signal-to-noise ratio of nonlinear movements in complex traffic scenarios.


2013 ◽  
Vol 19 (1) ◽  
pp. 10-12
Author(s):  
Lina Davies Forsman ◽  
Mats Öström ◽  
Mikael Svanström ◽  
Anders Eriksson

ABSTRACT We describe a fatality due to an intrathecally positioned epidural catheter and an infusion rate of bupivacaine set 10 times higher than planned. The undetected misplacement, despite safety routines, is discussed along with the toxicological findings and new information on the intrathecal distribution of bupivacaine. From a clinical point of view, the human factor, in combination with an indistinct decimal point on the pump, was considered as the reason for the unfortunate overdose. In continuous epidural infusion of local anesthetics, the importance of guidelines and informed staff in managing complications of epidural lumbar infusion as well as careful monitoring of the vital functions is essential. Guidelines are also vital during the procedure of insertion of epidural catheters. When using combined spinal and epidural anaesthesia, we believe that an epidural catheter should be inserted, and its position tested, prior to spinal anesthesia. The case also illustrates the need of innovative investigation techniques to confirm the suspicion of unusual manifestations of inadvertent drug effects. Segmental analysis, together with analyses in a control case, enabled us to elucidate the high and varying tissue concentrations in the central nervous system.


2020 ◽  
Vol 20 (5) ◽  
pp. 236-240
Author(s):  
Peter Andris ◽  
Ivan Frollo

AbstractThe article analyzes the sensitivity of unmatched receiving coil for the NMR scanner. Receiver of the scanner was investigated from the point of view of noise features. Theory of the noise figure has been modified to utilize the receiver for digitization of its own noise and the noise figure calculation. The resulting noise figure has been measured with different source impedances and the optimal value has been acquired. Influence of the noise figure on the resulting signal-to-noise ratio has been calculated for the sensitivity judgement. The output SNR has been investigated for constant input SNR as well as for constant input voltage. Many results are depicted in figures. Also examples of theoretical results are depicted graphically.


Sign in / Sign up

Export Citation Format

Share Document