scholarly journals Simulation Analysis of the Tensile Mechanical Properties of a Hydraulic Strain Clamp-Conductor System

2020 ◽  
Vol 2020 ◽  
pp. 1-19
Author(s):  
Zhongfei Ye ◽  
Kai Pang ◽  
Yuanxiang Du ◽  
Guifeng Zhao ◽  
Shao Huang ◽  
...  

Herein, a three-dimensional (3D) finite element model of a strain clamp-conductor system is established, with an NY-300/40 compression-type strain clamp taken as an example. The tensile load-carrying capacity of the strain clamp under standard crimping conditions is analyzed with LS-DYNA software, and the simulation results are compared with the experimental results to verify the accuracy of the model. On this basis, the tensile load-bearing capacity and failure mode of the strain clamp-conductor system are analyzed when the crimping length between the steel anchor and steel core is insufficient. Studies have shown that the grip strength of a strain clamp is provided mainly by the crimping between the steel anchor and the steel core. Under standard crimping conditions, the tensile load-bearing capacity of the strain clamp can meet the design requirements. Moreover, because the crimping length between the steel anchor and steel core is sufficient, the strain clamp fails due to aluminum strand breakage rather than the steel core being pulled out of the steel anchor. When the crimping length is insufficient, the grip strength of the strain clamp decreases with decreasing crimping length. Although the absolute value of the grip strength does not decrease significantly, the failure mode gradually changes from the breakage of the aluminum strands to the steel core being pulled out of the steel anchor. For the NY-300/40 compression-type strain clamp, the corresponding critical crimping length (i.e., when the change in failure modes occurs) between the steel core and the steel anchor is 50∼60 mm.

2011 ◽  
Vol 311-313 ◽  
pp. 1941-1944
Author(s):  
Gui Bing Li ◽  
Yu Gang Guo ◽  
Xiao Yan Sun

intermediate crack-induced debondingis one of the most dominant failure modes in FRP-strengthened RC beams. Different code models and provisions have been proposed to mitigateintermediate crack-induced debondingfailure.However, these models and provisions can not mitigate this failure mode effectively. Recnetly, new models have been proposed to solve this problem. Out of all the existing models, four typical ones are investigated in the current study. A comprehensivecomparison among these models is carried out in order to evaluate their performance and accuracy. Test results offlexural specimens with intermediate crack-induced debonding failurecollected from the existing literature are used in the current comparison. The effectivenessand accuracy of each model have been evaluated based on these experimental results. It is shown that the current modals are all conservative and inadequite to effectively mitigate intermediate crack-induced debonding in flexurally strengthened members.


2017 ◽  
Vol 2017 ◽  
pp. 1-20
Author(s):  
Ulf Arne Girhammar ◽  
Bo Källsner

The authors present an experimental and analytical study of slotted-in connections for joining walls in the Masonite flexible building (MFB) system. These connections are used for splicing wall elements and for tying down uplifting forces and resisting horizontal shear forces in stabilizing walls. The connection plates are inserted in a perimeter slot in the PlyBoard™ panel (a composite laminated wood panel) and fixed mechanically with screw fasteners. The load-bearing capacity of the slotted-in connection is determined experimentally and derived analytically for different failure modes. The test results show ductile postpeak load-slip characteristics, indicating that a plastic design method can be applied to calculate the horizontal load-bearing capacity of this type of shear walls.


2010 ◽  
Vol 163-167 ◽  
pp. 2171-2175 ◽  
Author(s):  
Jun Ping Liu ◽  
Yong Jian Liu ◽  
Jian Yang

Based on the experimental results, this paper presents the effects of concrete-filled in chord on the static behavior of rectangular hollow section (RHS) steel tubular trusses, including failure modes, load bearing capacity and structural stiffness. Failure of RHS trusses occurs at joints wether concrete-filled in chord or not, concrete-filled in chord changed the failure mode. Load bearing capacity and stiffness of joints subjected to compression load increased significantly, while it is limited to the tension joints. Concrete-filled in the compression chord tube can increase its stiffness significantly, while tension chord tube, it is not that obvious. Finally, based on the results discussed, failure modes and their formulas of calculating the load bearing capacity are discussed. Meanwhile, two methods, that is, amplified factor method and stiffness discounting method, which calculate the structural displacement when considering the joint deformation effects are presented.


2011 ◽  
Vol 20 (7) ◽  
pp. 510-516 ◽  
Author(s):  
Stephanie Dittmer ◽  
Marc Philipp Dittmer ◽  
Philipp Kohorst ◽  
Michael Jendras ◽  
Lothar Borchers ◽  
...  

2016 ◽  
Vol 20 (10) ◽  
pp. 1572-1585 ◽  
Author(s):  
Zi-qin Jiang ◽  
Yan-lin Guo ◽  
Ai-Lin Zhang ◽  
Chao Dou ◽  
Cai-Xia Zhang

The double rectangular tube assembled buckling-restrained brace is a new type of buckling energy consumption buckling-restrained brace. Because of its external restraining members, which are bound by high-strength bolts, its mechanical mechanism is more complicated and its failure modes are more varied. In this study, the double rectangular tube assembled buckling-restrained brace composition and three types of end constructions are introduced in detail. The influences of different design parameters on the performance of double rectangular tube assembled buckling-restrained brace are studied by numerical analysis methods; the possible failure modes and the influence of the end strengthening construction of double rectangular tube assembled buckling-restrained brace are also investigated, and a number of suggestions are proposed to improve this design. This study shows that the pinned double rectangular tube assembled buckling-restrained brace has four types of typical failure modes, namely, overall buckling failure, external end local pressure-bearing failure, bending failure of the extended strengthened core region and bolt threading failure. Rational design can prevent a buckling-restrained brace from losing its load-bearing capacity. In addition, compared with the end strengthening scheme with an external hoop, the end strengthening scheme with a strengthened bench can improve the load-bearing capacity of the double rectangular tube assembled buckling-restrained brace more effectively, and a reasonable design can also save materials.


2021 ◽  
Vol 60 (1) ◽  
pp. 64-79
Author(s):  
Junqing Hong ◽  
Shaofeng Zhang ◽  
Hai Fang ◽  
Xunqian Xu ◽  
Honglei Xie ◽  
...  

Abstract The performance of textile reinforced concrete composite panels (TRCCPs) under the action of pseudo-static load up to collapse was evaluated. The test of TRCCPs under axial and transverse loading was conducted, and the results were compared with those for steel wire mesh reinforced-concrete composite panels (SMRCCPs). Ceram-site concrete was utilized as the panel matrix owing to its lightweight and insulation characteristics. The ultimate load bearing capacity, load-deformation and load-strain relationships, and failure modes were discussed and investigated in comparison with the findings of non-linear finite-element-model (FEM) analysis and the analytic method on the basis of the reinforced concrete (RC) theory. The analysis results indicate that TRCCP is suitable for use as a potential structural member for a wall or slab system of buildings, and the typical RC theory can be applied to predict the ultimate load bearing capacity if modified suitably.


2011 ◽  
Vol 243-249 ◽  
pp. 5122-5127
Author(s):  
Jia Feng Xu ◽  
Ming Zhe Liu ◽  
Yue Feng Tang

This paper provided three test data pertaining to the mechanical properties of reinforced concrete columns after exposure to ISO834 standard fire and three comparative test data pertaining to the mechanical properties of reinforced concrete columns at room temperature, mainly concerning the influence of fire on failure mode, distortion performance and ultimate load bearing capacity of reinforced concrete columns under axial and eccentric compression. Test results show that the failure mode of reinforced concrete columns after exposure to fire is basically same with that at room temperature. With the same concrete strength and heating condition, the bearing capacity of specimens reduces as the eccentricity increases. Strain along the section height of eccentric columns after fire basically agree with the plane section supposition while the flexural rigidity and ultimate load bearing capacity decreases obviously. The residual load bearing capacity of reinforced concrete columns after exposure to fire is only about 25% to 37% of that at room temperature.


2011 ◽  
Vol 261-263 ◽  
pp. 765-769 ◽  
Author(s):  
Han Xu ◽  
Xiao Nong Guo ◽  
Yong Feng Luo

The application of Aluminum alloy T-stub joints has been found widely in China recently, while the research achievements of the joint are far from adequate for design. This paper is focused on the ultimate load-bearing capacity of aluminum alloy T-stub joints. On the basis of Kulak prying model, formulas for calculating ultimate load-bearing capacity, considering four types of failure modes, are derived. The numerical simulation is carried out by means of ABAQUS FEA. Numerical results are verified by comparing with previous results obtained from experimental analysis. A parametric analysis is performed to investigate the influence of several geometrical parameters on the behavior of aluminum alloy T-stub joints including failure modes, ultimate load-bearing capacity and effective length of flanges. These numerical results are also compared with those calculated by relevant formulas in EC9.


2007 ◽  
Vol 13 (3) ◽  
pp. 201-207 ◽  
Author(s):  
Saulius Kavaliauskas ◽  
Audronis Kazimieras Kvedaras ◽  
Balys Valiūnas

The purpose of this paper is to adopt the Johansen's yielding theory as a possibility to predict the ultimate load for timber‐to‐concrete joints using self‐tapping threaded connectors screwed at an angle into the wood. The ultimate load‐bearing capacity of a single connector is predicted to be when either the stresses in the wood reach the plastic failure stress level or when a combination of plastic failure in wood and dowel is attained. K. W. Johansen assumed that no axial tension occurred in the dowel and, thus no frictional contribution affected the lateral load‐bearing capacity. However, the joints with inclined fasteners are first affected by tension load, so the withdrawal capacity of the screws has to be taken into account. In order to determine the load bearing capacity for specific connector geometry, the kinematical possible failure modes are determined. The screw in the concrete part of connection was taken as rigidly embedded and thus no deformations appeared. The study showed that the load‐bearing capacity for connections with inclined high tensile strength screws can be predicted using the yielding theory, but this theory was unable to predict precisely the failure mode. Possible reasons for that include limited fastener ductility and influence of the screw inclination on the strength properties of timber.


Sign in / Sign up

Export Citation Format

Share Document