scholarly journals Enhancement of Nutrient Removal in a Hybrid Constructed Wetland Utilizing an Electric Fan Air Blower with Renewable Energy of Solar and Wind Power

2015 ◽  
Vol 2015 ◽  
pp. 1-8
Author(s):  
Dong Jin Lee ◽  
Se Won Kang ◽  
Jong Hwan Park ◽  
Seong Heon Kim ◽  
Ik Won Choi ◽  
...  

The sewage treatment efficiency of hybrid constructed wetlands (CWs) was evaluated under different ventilation methods. The removal efficiencies of biochemical oxygen demand (BOD), total nitrogen (TN), and total phosphorus (TP) in the vertical flow- (VF-) horizontal flow (HF) CWs using an electric fan air blower by the renewable energy of solar and wind power were higher than those by natural ventilation, excluding only suspended solids (SS). The TN treatment efficiency in the CW using the air blower especially increased rapidly by 16.6% in comparison with the CW employing natural ventilation, since the VF bed provided suitable conditions (aerobic) for nitrification to occur. The average removal efficiencies of BOD, SS, TN, and TP in the effluent were 98.8, 97.4, 58.0, and 48.3% in the CW using an electric fan air blower, respectively. The treatment performance of the CWs under different ventilation methods was assessed, showing TN in the CW using an electric fan air blower to be reduced by 57.5~58.6% for inlet TN loading, whereas reduction by 19.0~53.3% was observed in the CW with natural ventilation. Therefore, to increase the removal of nutrients in CWs, an improved ventilation system, providing ventilation via an electric fan air blower with the renewable energy, is recommended.

2013 ◽  
Vol 2013 ◽  
pp. 1-6
Author(s):  
Dong Sheng Shen ◽  
Bao Cheng Huang ◽  
Hua Jun Feng ◽  
Bo Zhao ◽  
Jiang Ming Zhao ◽  
...  

A novel decentralised sewage treatment reactor (DSTR) for treating domestic sewage in rural areas was designed and investigated. The reactor was started aerobically after inoculation with biomass; the amount of initial mixed liquid suspended solids was 1.5 g/L. Oxygen was supplied to the reactor and the dissolved oxygen concentration was maintained at 1.3 ± 0.2 mg/L. The pollutant removal performance was investigated, and the average removal efficiencies of total chemical oxygen demand (TCOD),NH4+-N, suspended solids, and turbidity were 76%, 77.15%, 84.17%, and 83.93%, respectively. The DSTR exhibited good performance compared with the traditional activated sludge (AS) reactor. The resistance to impact load of the DSTR was superior to that of the AS reactor during surface load experiments. During the 120 days of operation, no sludge bulking was observed. The DSTR effluentNH4+-Nand TCOD levels were a little higher than those for the AS reactor, but the disparity was not major.


2012 ◽  
Vol 518-523 ◽  
pp. 2431-2438
Author(s):  
Ying Zhang Wang ◽  
Shang Hua Zhang ◽  
Chang Qing Pang ◽  
Jie Li

Luffa cylindrical sponge and plastic sponge were used as carriers in sequencing batch biofilm reactor (SBBR) for sewage treatment in this paper. The removals of suspended solid (SS), chemical oxygen demand (COD) and NH3-N in sewage were studied. The average removal efficiencies of SS, COD and NH3-N with luffa cylindrical sponge were 96%, 89% and 90%, respectively, while these with plastic sponge were 94%, 83% and 80%, respectively. As a natural, cheap and environment friendly biocarrier, luffa cylindrical sponge was easy to get a biofilm with enriched microbes during the first few days of sewage treatment. It was much more suitable as a carrier than the plastic sponge for SBBR.


2014 ◽  
Vol 34 (4) ◽  
pp. 770-779 ◽  
Author(s):  
Fábio Orssatto ◽  
Marcio A. Vilas Boas ◽  
Ricardo Nagamine ◽  
Miguel A. Uribe-Opazo

The current study used statistical methods of quality control to evaluate the performance of a sewage treatment station. The concerned station is located in Cascavel city, Paraná State. The evaluated parameters were hydrogenionic potential, settleable solids, total suspended solids, chemical oxygen demand and biochemical oxygen demand in five days. Statistical analysis was performed through Shewhart control charts and process capability ratio. According to Shewhart charts, only the BOD(5.20) variable was under statistical control. Through capability ratios, we observed that except for pH the sewage treatment station is not capable to produce effluents under characteristics that fulfill specifications or standard launching required by environmental legislation.


2020 ◽  
Vol 81 (9) ◽  
pp. 1951-1960 ◽  
Author(s):  
C. S. Cabral ◽  
A. L. Sanson ◽  
R. J. C. F. Afonso ◽  
C. A. L. Chernicharo ◽  
J. C. Araújo

Abstract Two bioreactors were investigated as an alternative for the post-treatment of effluent from an upflow anaerobic sludge blanket (UASB) reactor treating domestic sewage, aiming at dissolved sulfide and methane removal. The bioreactors (R-control and R-air) were operated at different hydraulic retention times (HRT; 6 and 3 h) with or without aeration. Large sulfide and methane removal efficiencies were achieved by the microaerated reactor at HRT of 6 h. At this HRT, sulfide removal efficiencies were equal to 61% and 79%, and methane removal efficiencies were 31% and 55% for R-control and R-air, respectively. At an HRT of 3 h, sulfide removal efficiencies were 22% (R-control) and 33% (R-air) and methane removal did not occur. The complete oxidation of sulfide, with sulfate formation, prevailed in both phases and bioreactors. However, elemental sulfur formation was more predominant at an HRT of 6 h than at an HRT of 3 h. Taken together, the results show that post-treatment improved the anaerobic effluent quality in terms of chemical oxygen demand and solids removal. However, ammoniacal nitrogen was not removed due to either the low concentration of air provided or the absence of microorganisms involved in the nitrogen cycle.


2018 ◽  
Vol 78 (9) ◽  
pp. 1879-1892 ◽  
Author(s):  
Md Khalekuzzaman ◽  
Muhammed Alamgir ◽  
Mehedi Hasan ◽  
Md Nahid Hasan

Abstract In this research, a hybrid anaerobic baffled reactor (HABR) configuration was proposed consisting of a front sedimentation chamber and four regular baffled chambers followed by two floated filter media chambers for the treatment of domestic wastewater. Performance comparison of uninsulated and insulated HABRs was carried out operating at warm temperature (18.6–37.6 °C) under variable HRTs (30 h and 20 h). The study suggests that almost similar chemical oxygen demand (91% vs 88%), total suspended solids (90% vs 95%), turbidity (98% vs 97%), and volatile suspended solids (90% vs 93%) removal efficiencies were obtained for uninsulated and insulated HABRs. Higher removal of total nitrogen (TN) of 41%, NH4+-N of 44%, and NO3−-N of 91% were achieved by the insulated HABR compared to TN of 37%, NH4+-N of 36%, and NO3−-N of 84% by the uninsulated HABR, whereas lower PO43− removal efficiency of 17% was found in the insulated HABR compared to 24% in the uninsulated HABR. This indicated insulation increased nitrogen removal efficiencies by 4% for TN, 8% for NH4+-N and 7% for NO3−-N, but decreased PO43−removal efficiency by 7%.


Author(s):  
Tomáš Vítěz ◽  
Jana Ševčíková ◽  
Petra Oppeltová

This paper is focused on primary, secondary, and total efficiency evaluation of the wastewater treatment process for chosen small wastewater treatment plant (WWTP) located near the Moravian Karst. Eight wastewater samples were taken during one year in three sampling profiles of WWTP: biochemical oxygen demand (BOD), chemical oxygen demand (COD), suspended solids (SS), pH, ammonia nitrogen (N-NH4), nitrite nitrogen (N-NO2), nitrate nitrogen (N-NO3), inorganic nitrogen (Ninorg), total phosphorus (Ptotal). Treatment efficiency by reduction was calculated for all laboratory analyzed indicators and average values were determined for the whole period. Calculated treatment efficiency of indicators BOD, COD and suspended solids was compared with the permissible minimum treatment efficiency of discharged waste water by Government Regulation No. 61/2003 Coll., for the WWTP from 500 to 2 000 PE. Permissible minimum treatment efficiency is not legislatively determined for the primary and secondary level. The results of the work will be used especially to compare results with other similar works.Analyzed values ​​of parameters BOD, COD, suspended solids, N-NH4 at the outflow from wastewater treatment plant were compared with the permissible maximum values at the outflow of the WWTP which the municipality has an obligation to respect according to the decision issued by the District Environment Authority.


2013 ◽  
Vol 11 (4) ◽  
pp. 546-555 ◽  

Treatability by the electro-coagulation (EC) and electro-Fenton (EF) methods have been applied to the tannery wastewater from an organized industrial region consisting mostly of tannery plants and compared with each other in this study. Iron plates were used as the anode and cathode. Electrical current was applied at a value of 33.3 mA m-2 for all processes in order to determine the electricity consumptions for chemical oxygen demand (COD) and sulfide removal. The optimal contact duration for each process was discovered at the end of the first five minutes. During the EC process, the removal efficiencies of COD and sulfide were 46% and 90%, respectively. Electricity consumptions were also obtained as 1.8 kWh kg- 1 COD removed and 27.7 kWh kg-1 sulfide removed. During the EF process, on the other hand, the removal efficiencies of COD and sulfide parameters were 54% and 85%, respectively, and electricity consumptions were also obtained as 1.5 kWh kg-1 COD removed and 8.3 kWh kg-1 sulfide removed. Furthermore, the removal efficiencies of total Chrome and suspended solids were determined to be 97% and 70%, respectively.


2019 ◽  
Vol 268 ◽  
pp. 06007
Author(s):  
Jahziel Lantin ◽  
Jeremy Ynnos Abenoja ◽  
Jason Ly ◽  
Cheenee Marie Castillones ◽  
Arnel Beltran ◽  
...  

Assessment and upgrade of existing sewage treatment plants (STPs) are necessary due to the revision of the existing effluent regulations which now monitors nutrients including ammonia, nitrate and phosphates. The aim of this study is the performance evaluation of four sequencing batch reactor (SBR) type of STP based on the following parameters: biological oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS), nitrates, ammonia, phosphates and pH; and their potential upgrade based on the revised regulations stated in DAO 2016-08. Four sequencing batch reactor (SBR) type of STP were assessed for 12 weeks for this study. Results showed noncompliance with nutrient levels, thus upgrade is necessary. Analytical Hierarchy Process (AHP), a Multi-Criteria-Analysis (MCA) tool, was used to select the best option for upgrade among options that include (1) additional SBR tank, (2) diverting wastewater to another treatment facility, and (3) converting the SBR into membrane bioreactor (MBR). Considering the criterion for upgrade, option 2 was the most preferred decision followed by option 1 then option 3.


1973 ◽  
Vol 8 (1) ◽  
pp. 122-147
Author(s):  
J. D. O’Blenis ◽  
T.R. Warriner

Abstract The current widespread practice of disposal of water filtration plant wastes by direct discharge to receiving waters is coming under critical review by regulatory agencies. Among the alternatives for management of these wastes is the possibility of disposal to sanitary sewer systems. Since a recent nation-wide survey had established alum sludge as the most common waste generated by filtration plants, research was initiated to study the effects of water plant alum sludge on primary sewage treatment. A pilot primary sewage treatment plant was constructed and operated with a raw sewage feed of five litres per minute. A laboratory jar test program was conducted to supplement pilot plant operation. Sludges from two different water purification plants were tested along with alum and combinations of alum and water purification plant sludge for their effects on the removal of suspended solids, chemical oxygen demand (COD) and phosphates. The data showed jar testing to be a good indicator of pilot plant performance. Suspended solids, COD and phosphate removal efficiencies were improved by the addition of the sludges. The phosphate removal capacity of water treatment plant alum sludge was approximately the same as that reported for aluminum hydroxide, or about 1/7 to 1/9 of that determined for alum (as Aluminum). Recycling of the sludges improved phosphate removal performance.


1987 ◽  
Vol 22 (3) ◽  
pp. 474-490 ◽  
Author(s):  
R.L. Droste ◽  
S.R. Guiot ◽  
S.S. Gorur ◽  
K.J. Kennedy

Abstract Anaerobic treatment of dilute synthetic wastewater (300-1,000 mg chemical oxygen demand/L using laboratory upflow sludge blanket filter reactors with and without effluent recycle is described. Treatment of dilute synthetic wastewater at hydraulic retention times less than 1 and 2 h in reactors without and with recycle, respectively, resulted in biomass washout as the solids retention time decreased to less than 12 d. Reseeding would be required to operate at these critical hydraulic retention times for extended periods. Treatment of dilute synthetic wastewater at hydraulic retention times between 3-12 h resulted in soluble COD removal efficiencies between 84-95% treating 300 mg COD/L. At a 3 h hydraulic retention time, solids retention time of 80 d and stable reactor biomass concentrations of 25 g volatile suspended solids/L were maintained.


Sign in / Sign up

Export Citation Format

Share Document