Hyun-Sik Park ◽  
Byung-Yeon Min ◽  
Youn-Gyu Jung ◽  
Yong-Cheol Shin ◽  
Yung-Joo Ko ◽  
...  

To validate the performance and safety of an integral type reactor of SMART, a thermal-hydraulic integral effect test facility, VISTA-ITL, is introduced with a discussion of its scientific design characteristics. The VISTA-ITL was used extensively to assess the safety and performance of the SMART design, especially for its passive safety system such as a passive residual heat removal system, and to validate various thermal-hydraulic analysis codes. The VISTA-ITL program includes several tests on the SBLOCA, CLOF, and PRHRS performances to support a verification of the SMART design and contribute to the SMART design licensing by providing proper test data for validating the system analysis codes. A typical scenario of SBLOCA was analyzed using the MARS-KS code to assess the thermal-hydraulic similarity between the SMART design and the VISTA-ITL facility, and a posttest simulation on a SBLOCA test for the shutdown cooling system line break has been performed with the MARS-KS code to assess its simulation capability for the SBLOCA scenario of the SMART design. The SBLOCA scenario in the SMART design was well reproduced using the VISTA-ITL facility, and the measured thermal-hydraulic data were properly simulated with the MARS-KS code.

Author(s):  
K. Y. Choi ◽  
S. Cho ◽  
S. J. Yi ◽  
H. S. Park ◽  
N. H. Choi ◽  
...  

The SMART is an integral type reactor with new innovative design features aimed at achieving a highly enhanced safety and improved economics. This paper focuses on the thermal hydraulic experimental program for the development of SMART. Thermal hydraulic responses for the transient operations of the SMART-P are experimentally investigated by using an integral effect test facility. The test facility (VISTA) has been constructed to simulate the SMART-P, which is a pilot plant of the SMART. The VISTA facility is a full height and 1/96 volume scaled test facility with respect to the SMART-P with a power of 65MWt. In the present study, the VISTA facility was subjected to various transient conditions in order to understand the thermal-hydraulic responses following transients and finally to verify the system design of the SMART-P. Several experiments, including a heatup, a main coolant pump (MCP) speed change, and a power change, have been performed to investigate the heat transfer characteristics and the natural circulation performance of the primary system and the Passive Residual Heat Removal System (PRHRS) of the SMART-P by using the VISTA facility. Performance tests of a passive residual heat removal system (PRHRS) have also been carried out for its design optimization. Besides, several design basis accidents, such as an increase or a decrease of the feedwater flow, a loss of coolant flow, a control rod withdrawal, and a limited case of a loss of coolant accident (LOCA) on the line to the gas cylinder are under investigation in order to understand the thermal-hydraulic responses and finally to verify the system design of the SMART-P. Especially, the details of the experimental results for a loss of feedwater accident and a power increase accident due to a control rod withdrawal are explored in the present study.


Author(s):  
T. Gocht ◽  
W. Kästner ◽  
A. Kratzsch ◽  
M. Strasser

In case of an accident the safe heat removal from the reactor core with the installed emergency core cooling system (ECCS) is one of the main features in reactor safety. During a loss-of-coolant accident (LOCA) the release of insulation material fragments in the reactor containment can lead to malfunctions of ECCS. Therefore, the retention of particles by strainers or filtering systems in the ECCS is one of the major tasks. The aim of the presented experimental investigations was the evaluation of a filtering system for the retention of fiber-shaped particles in a fluid flow. The filtering system consists of a filter case with a special lamellar filter unit. The tests were carried out at a test facility with filtering units of different mesh sizes. Insulation material (mineral rock wool) was fragmented to fiber-shaped particles. To simulate the distribution of particle concentration at real plants with large volumes the material was divided into single portions and introduced into the loop with a defined time interval. Material was transported to the filter by the fluid and agglomerated there. The assessment of functionality of the filtering system was made by differential pressure between inlet and outlet of the filtering system and by mass of penetrated particles. It can be concluded that for the tested filtering system no penetration of insulation particles occurred.


2018 ◽  
Vol 215 ◽  
pp. 01017
Author(s):  
Arfidian Rachman ◽  
Lisa Nesti

For areas with very hot and humid weather condition increased latent and sensible load are a major problem in cooling systems that will increase compressor work so that electricity consumption will also increase. Combined condenser with direct evaporate cooling will increase the heat removal process by using an evaporative cooler effect that will increase the efficiency of energy use. This paper presents the study of the use of evaporator cooling and condenser. This paper mainly calculated energy consumption in steam compression cooling systems and related problems. From the results of this study, the use of condensers with evaporative cooling, power consumption can be reduced to 46% and performance coefficient (COP) can be increased by about 12%, with 1,2 kW cooling capacity.


Author(s):  
Hae-Yong Jeong ◽  
Kwi-Seok Ha ◽  
Kwi-Lim Lee ◽  
Young-Min Kwon ◽  
Won-Pyo Chang ◽  
...  

PHENIX, a prototype sodium-cooled fast reactor (SFR), has demonstrated a fast breeder reactor technology and also achieved its important role as an irradiation facility for innovative fuels and materials. In 2009 PHENIX reached its final shutdown and the CEA launched a PHENIX end-of-life (EOL) test program, which provided a unique opportunity to validate an SFR system analysis code. The Korea Atomic Energy Research Institute (KAERI) joined this program to evaluate the capability and limitation of the MARS-LMR code, which will be used as a basic tool for the design and analysis of future SFRs in Korea. For this purpose, pre-test analyses of PHENIX EOL natural circulation tests have been performed and one-dimensional thermal-hydraulic behaviors for these tests have been analyzed. The natural circulation test was initiated by the decrease of heat removal through steam generators (SGs). This resulted in the increase of intermediate heat exchanger (IHX) secondary inlet temperature, followed by a manual reactor scram and the decrease of secondary pump speed. After that, the primary flow rate was also controlled by the manual trip of three primary pumps. For the pre-test analysis the Phenix primary system and IHXs were nodalized into several volumes. Total 981 subassemblies in the core were modeled and they were divided into 7 flow channels. The active 4 IHXs were modeled independently to investigate the change of flow into each IHX. The cold pool was modeled by two axial nodes having 5 and 6 sub-volumes, respectively. The reactor vessel cooling system was modeled to match the flow balance in the primary system. The flow path of vessel cooling system was quite complicated. However, it is simplified in the modeling. For a MARS-LMR simulation, the dryout of SGs have been described by the use of the boundary conditions for IHTS as a form of time-to-temperature table. This boundary condition reflects the increase in IHTS temperature by SG dryout during the initial stage of the transient and the increase in heat removal by the opening of the two SG containments at 3 hours after the initiation of the transient. Through the comparison of the pre-analysis results with the prediction by other computer codes, it is found that the MARS-LMR code predicts natural circulation phenomena in a sodium system in a reasonable manner. The final analysis for validation of the code against the test data will be followed with an improved modeling in near future.


2012 ◽  
Vol 135 (2) ◽  
Author(s):  
Onder Ozgener ◽  
Leyla Ozgener

The present manuscript experimentally investigated the exergetic performance (efficiency) of a closed loop earth to air heat exchanger (underground air tunnel) in the cooling mode. The experimental system was commissioned in June 2009 and experimental data collecting have been conducted since then. The data, consisting of hourly thermodynamics records a year cooling period, 2009–2011, were measured in the Solar Energy Institute of the Bornova Campus at Ege University. At the present time, the database contains more than 40,000 records of measurements. Exergetic efficiencies value of the system and system components have been analyzed. Furthermore, a long term exergetic modeling of a closed loop earth-to-air heat exchanger solar greenhouse cooling system for system analysis and performance assessment is presented. Exergetic efficiency of the system and its compenents at various reference states are also determined.


Author(s):  
Wei Li ◽  
Shuhong Du ◽  
Weiquan Gu ◽  
Nan Zhang ◽  
Ming Ding ◽  
...  

Abstract HPR1000 is an advanced nuclear power plant with the significant feature of an active and passive safety design philosophy, developed by the China National Nuclear Corporation. It is based on the large accumulated knowledge from the design, construction as well as operations experience of nuclear power plants in China. The passive containment cooling system (PCS) of HPR1000 is an important and innovative passive safety system to suppress the pressure in the containment during LOCA. In this paper, the detailed design process of PCS is reviewed, and an integrated experiment facility for the study on the coupling behavior between PCS and thermal hydraulic characteristics in the containment is described, and arrangement of measuring points including temperature, pressure, gas composition and so on are introduced in detailed. Also, the experimental energy released and energy vent to ensure the similarity of containment pressure response, thermal stratification and PCS heat removal is introduced. According to this versatile experiment facility can conduct real-engineering system test which is designed to support the PCS development. In addition, this valuable experience in the design and manufacture of integrated experiment facility can provide important technical support and guidance for the China next generation advanced PWR as well as safety related system.


2006 ◽  
Vol 33 (3) ◽  
pp. 262-270 ◽  
Author(s):  
Young-Jong Chung ◽  
Hee-Cheol Kim ◽  
Bub-Dong Chung ◽  
Moon-Ki Chung ◽  
Sung-Quun Zee